63
ENGLISH
2.3 Photocells
2.4 Sensors
Sets the status of “external radar” and “internal radar” commands
(E-Det and I-Det inputs on control board).
No
Normally open input.
Nc
Normally closed input.
2.5 Key
Sets the status of the “key” command (Key input on the control
board).
No
Normally open input.
Nc
Normally closed input.
2.6 Out 1
Sets function or status associated with individual outputs on the
control board.
Standard setting OUT 1: Gong/NO
The outputs OUT2 and OUT3
The outputs OUT2 and OUT3
Not available in the
in the
automated system
automated system
Function/Status
The output is activated according to selection:
3 VARIOUS
3.1 Stand Setup
Used for checking if any non-standard programming operation
was effected.
Standard
If no function was modified with respect to the standard
programming, an asterisk is shown.
If the asterisk is not present, press the “OK” key and all standard
programming functions are reset.
No Standard
If at least one function was modified with respect to the standard
programming, an asterisk is shown.
3.2 Interlock
The interlock function makes it possible to control two sliding doors
(master and slave) so that opening of one depends on closing
of the other and vice versa.
Off
Interlock function not active.
On
Activates the interlock function.
Master
The master door (usually the internal one).
Slave
The slave door.
No Memory
With interlock operation, you must wait for one door to re-close
before commanding the other to open: any opening pulses sent
during the operating cycle of the first door, have no effect.
With Memory
With interlock operation, there is no need to wait for one door to
re-close before commanding the other to open: any opening
pulses sent during the operating cycle of the first door are
memorised, and the second door opens automatically as soon
as the first door closes.
3.3 Elastic kit
The elastic kit is a mechanical accessory that, after installation,
The elastic kit is a mechanical accessory that, after installation,
enables the anti-panic opening of the leaves in the event of a
enables the anti-panic opening of the leaves in the event of a
power cut.
power cut.
Off
Off
Elastic kit not installed.
Elastic kit not installed.
On
On
Elastic kit installed.
Elastic kit installed.
Standard - No Standard
Standard - No Standard
When power is supplied again after a power cut, the door
When power is supplied again after a power cut, the door
automatically executes the necessary movement to reset the
automatically executes the necessary movement to reset the
device.
device.
Exception: door set in manual mode.
Exception: door set in manual mode.
Important!: during the automatic reset of
Important!: during the automatic reset of
the system, thenti-crushing function is disabled.
the system, thenti-crushing function is disabled.
SELECTION
OUTPUT ACTIVATION
OPEN
Until the door is open
MOVING
Until door is moving
NOT CLOSED
Until door is not closed
ALARM
Until the door is in alarm status
GONG
Intervention of photocells activates the
output for 1 sec. at 0.5 sec. intervals until
release.
LIGHT
In “night” operational function, when the
door is commanded to open, the output
is activated for 60 sec.
INTERLOCK(*)
The output is activated to create an
interlock between the doors
No
Normally open input.
Nc
Normally closed input.
(*) The “interlock” function cannot be selected but is automatically
set on the OUT1 output when the interlock is activated (see
Various/Interlock).
No
Normally open output.
Nc
Normally closed output.
WARNING:
TO SET PARAMETERS OF MENU 2.3 PHOTOCELLS,
USE THE DISPLAY ONLY. DO NOT SET PARAMETERS
FROM SD-KEEPER .