14
Lt
Vp
ENGLISH
A.
ASSEMBLY OF IN-KIT AUTOMATED SYSTEMS
1A PREPARING THE SUPPORT PROFILE
Support profiles are available in two sizes:
6100 mm.
Cut the support profile to measure using the following formula:
LT = Vp x 1,5 + 100
Where:
• Lt
is the length of the support profile
• VP
is the transit space
• 100
are the overlap millimeters between the leaves .
This section describes the assembly of the in-kit automated systems. After you have prepared the necessary profiles, we advise you
to assemble and install at the same time.
Automation free-standing refer to Chapter 21
fig. 9
1.1A SUPPORT PROFILE - SECURING ON WALL
Define the exact height position of the support profile, consider-
ing the dimensions
The cross beam must be fastened parallel to the floor
The distance between the top of the support profile
and the ceiling must be 80mm. Rif.Fig.10
Initially fix the support profile on a vertical slot at one end, and
on a horizontal slot at the other end (using M8 screws and
appropriate expansion plugs which are not supplied) and level
parallel to the floor. Fasten centrally, lifting the support profile with
force to align the three securing points. Carry out the remaining
fastenings.fig.10.