45
1
2
3
4
5
6
7
8
9
10
11
12
13
J7
I-DET
E-DET
KEY
EMERG1
EMERG2
-FAILSAFE
OUT1
+24V
+24V
GND
GND
P
P
ENGLISH
TERMINAL BOARD
J7
DESCRIPTION OF TERMINALS
TERMINAL BOARD J7
1
I-DET
(NO contact default)
Internal sensor input.
By using SD-Keeper with Display (Accessory), you can modify the
polarity of the contact to N.C.
2
E-DET
(NO contact default)
External sensor input.
By using SD-Keeper with Display (Accessory), you can modify the
polarity of the contact to N.C.
3
KEY
(NO contact default)
Key command:
activation causes the door to open, closing it after night pause
time.
By using SD-Keeper with Display (Accessory), you can modify the
polarity of the contact to N.C.
4
EMERG1
(NO contact default)
Emergency command 1:
in the standard setting, activation causes the door to stop (for as
long as it is maintained active, the door stays in stop condition).
By using SD-Keeper with Display (Accessory), you can program
the operation of this input in a different way (see programming
instructions).
the EMERG1 command has priority over EMERG2
5
EMERG2
(NO contact default)
Emergency command 2:
in the standard setting, activation causes the door to open (for
as long as it is maintained active, the door stays open).
By using SD-Keeper with Display (Accessory), you can program
the operation of this input in a different way (see programming
instructions).
6 PROTECTION
1
Protection 1 input.
Use monitored safety devices that comply with EN16005
standard.
7 PROTECTION
2
Protection 2 input.
Use monitored safety devices that comply with EN16005
standard.
8 -FAIL-SAFE
Negative for powering monitoring sensors.
9 OUT
1
(“gong”
default)
Output (negative) of open-collector (max 100mA).
In the standard setting, this output is active when the
photocells are shadowed for 1 sec. at intervals of 0.5 sec.until
disengagement.
By using SD-Keeper with Display (Accessory), you can program
the operation of this output in a different way (see programming
instructions).
10-11 +24V=
+24V= for powering accessories
The maximum total load of the accessories connected to inputs
”+24V=” must not exceed 1 A.
12-13 GND
Negative for powering accessories and common contact.