A1000
93
532210 04 - Rev.A
Tr
ansla
tion of the original instruc
tions
ENGLISH
OK
OK
OK
200 UC FAILURE
3
ERRORS
201...................221
222 TEST VMAIN
1 ERRORS
2 AUX ERRORS
OK
The display shows current errors:
-
200 UC fault (Corrupted FW or corrupted RAM)
-
201 Aux Mot failure
-
202 High
friction
-
203 Aux Mot Driver
-
204 FW Not Compatible
-
205 Motor
rotation
-
206 Encoder
failure
-
216 Communication
(Communication problem between the 2 boards)
-
217 Incorrect opening position
-
218 Obstacle
-
219 Incorrect
ID
-
220 Vmain
-
221 Timeout
-
222 Vmain
Test
MENU 4 INDICATIONS
OK
OK
OK
OK
41 TIME LOSS
4
WARNINGS
42.....................74
80 NON STANDARD
PROGRAM.
The display shows current alerts:
-
41 Date and time missing
-
42 Clock battery discharged or missing
-
44 Emergency
active
-
45 TIMER
active
(indicated with
T
on HOME PAGE)
-
46 Timer function in progress
-
47 Last movement carried out with battery
-
48 Night-time mode operation
-
49 Manual mode operation
-
50 Partial mode operation
-
51 Obstacle during closing
-
52 Obstacle during opening
-
53 Number of maintenance cycles corrupted
-
54 Motor block failure
-
55 Pharmacy mode operation
-
56 Battery
operation
-
57 Searching for opening stop
-
58 Searching for closing stop
-
59 Motor block fault (only with monitoring KIT)
-
60 Maintenance request
-
61 SDK EVO / LK EVO
/ KSEVO fault
-
62 Battery charger failure
-
63 Intrusion in progress
-
65 SETUP in progress
-
67 Battery saving
-
68 Safety devices test failed
-
69 Semi-automatic input keeps door open
-
70 Battery charge level
-
71 Slave Intercom
-
72 CANBUS Failure
-
73 Intercom Node Alarm
-
74 INTERLOCK operating mode active
-
80 Programming other than standard
MENU 5 CYCLE COUNTER
OK
OK
OK
OK
5
CYCLES COUNT
CYCLES RESET
MAINTENANCE
CYCLES NUMBER
■
1 Number of cycles
The display shows the number of cycles performed:
-
ABSOLUTE
counter not resettable
-
RELATIVE
counter resettable (with CYCLE RESET)
■
2 Maintenance
To set the deadlines for maintenance request:
-
DATA (default: disabled) 00/00/00
-
number of cycles
minimum: 1000; maximum 1000000
Entering a date is optional.
■
3 RESET CYCLES
It resets RELATIVE cycle counter to zero. This command requires
confirmation
The ABSOLUTE cycle counter cannot be reset to zero.
MENU 6 DATE / TIME
OK
OK
OK
OK
SET DATE
6
DATE/TIME
SET TIME
DAYLIGHT SAV TIME
■
SET DATE
Set date in dd/mm/yy.
■
SET TIME
Set time in HH:mm.
■
EUROPEAN DAYLIGHT SAVING TIME
European daylight saving time is enabled by default.
Available options are:
Summary of Contents for A1000