![background image](http://html2.mh-extra.com/html/faac/a1000/a1000_user-manual_3115220046.webp)
A1000
46
532210 04 - Rev.A
0.0
RESET/SETUP
DL2
DL11
MAIN
F1
USB
+
-
F
ERR
BAT1
OPEN
EMERG
BAT2
SIC_OP
SIC_CL
J10
J14
J11
J12
J13
V G
S1
G
T
J1
J17
V RX
TX G
J8
E1 G E2
J7
T1 G
T2
R1
G R2
J9
V G 01 02 02
J22
J21
V
G
I1
I2
G
I3
I4
V
J18
G CH CL
G
J23
J24
J25
V G
S2
G
T
J2
J25
J22
J18
J7
J4
J1
J9
J23
J24
J17
J13
J12
J11
J14
J10
58
J21
J8
Tr
ansla
tion of the original instruc
tions
ENGLISH
IMPORTANT The maximum total load of accessories connected to board
V (+24V
) must not exceed 1A. (except SDK-EVO)
J1 J4 - INPUTS S1-S2
T
TEST
G
GND Power supply negative and Common contacts
S1
S2
Configurable inputs S1-S2
G
GND Power supply negative and Common contacts
V
+24V
(accessories power supply)
Default inputs for safety in closing devices § 12.5. IMPORTANT: Use moni-
tored safety devices compliant with standard EN 16005:2012
J7 - INPUTS E1 -E2
E1 G E2
J7
E2
Configurable input E2
G
GND Accessories power supply negative and Common contacts
E1
Configurable input E1
Inputs recommended for emergency functions
J8 - SDK EVO - LK EVO - KS EVO
V RX
TX G
J
J8
G
GND Accessories power supply negative and Common contacts
TX
Data transmission
RX
Data reception
V
+24V
accessories power supply
J9 - XFA BUTTON PHOTOCELLS
T1 G
T2
R1
G R2
J9
R2
2nd pair receiver connection
G
GND Receiver negative
R1
1st pair receiver connection
T2
2nd pair transmitter connection
G
GND Transmitter negative
T1
1st pair transmitter connection
J10 - MAIN POWER SUPPLY 36V - 4A
0
J10
+36V
Switching power supply unit connection
12.2 TERMINAL BOARDS AND CONNECTORS
V G
S2
G
T
J4
V G
S1
G
T
J1
Summary of Contents for A1000
Page 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Page 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Page 110: ...A1000 110 53221004 Rev A...
Page 114: ...A1000 114 53221004 Rev A...
Page 115: ...Translation of the original instructions ENGLISH...