Defines the automation’s behaviour with emergency battery, in case
of mains power outage. Available options are:
1. FUNCTION
-
Disabled
-
Until the last movement
-
Now last motion
2. LAST MOVEMENT
-
Opening
-
Closing
3. NIGHT-TIME FUNCTION
-
Now last motion
-
Until the last movement
4. LAST MOVEMENT NIGHT
-
Closing
-
Opening
If the door is in NIGHT-TIME, battery operation is not active.
Default CF1 CF2 CF2 CF4 CF5
FUNCTION
Disabled ---
LAST MOVEMENT
Opening
NIGHT-TIME FUNCTION
Until the last movement
LAST MOVEMENT NIGHT Closing
■
6 MOTOR BLOCK KIT
OK
OK
MOTOR BLOCK KIT
2
PROGRAMMING
Defines the motor block behaviour
(OPTIONAL accessory)
Options:
-
1 LOCK TYPE
-
2 FUNCTION
-
3 MONITORING KIT
-
4 BATTERY OPERATION
1 LOCK TYPE
Defines the type of motor block:
-
XB LOCK
-
XM LOCK
2 FUNCTION
Defines operating methods in which motor block is activated;
-
Disabled
-
Night
-
Night + Open
-
Night-time and One-directional
-
Always
3 MONITORING KIT
Enables/disables monitoring on motor block;
-
ENABLED
-
DISABLED
If the monitoring kit (OPTIONAL accessory) is not installed, disable.
4 BATTERY OPERATION
Defines battery operation of the motor block:
-
STANDARD: the mode of operation selected is kept even with
battery operation.
-
NIGHT: motor block active only in NIGHT-TIME mode.
-
ALWAYS OPEN: motor block active in OPEN mode
* the REVERSE parameter determines the reverse speed of the leaf during
closing with a 5-level setting from 1 (slow) to 5 ( fast).
Default CF1 CF2 CF2 CF4 CF5
SPEED
5 5 5 5 ---
SLOWDOWN
1 1 1 1 ---
SLOWDOWN SPEED
1 1 1 1 ---
FORCE
5 5 5 5 ---
FORCE TIME
1.0 1.0
2.0
1.0 ---
ACCELERATION
8 8
5 8 ---
DECELERATION
6 6
6 4 ---
REVERSE
5 5
5 5 - --
MOVEMENT DAMPING
Select and modify the parameter from the list:
-
MOVEMENT DAMPING (
*)
1-5
* the
MOVEMENT DAMPING
parameter enables the deceleration
ramp to be programmed in the event of a stop or a reverse movement.
Default CF1 CF2 CF2 CF4 CF5
MOVEMENT DAMP. 5 5 5 5 ----
STOP OPEN
Select and modify the parameter from the list:
-
STOP OPEN (
*)
0-10
* the STOP OPEN parameter allows you to program the motor to stop in
advance in correspondence to the passage opening.
Default CF1 CF2 CF2 CF4 CF5
STOP OPEN 5 5 5 5 ----
■
3 TIMING
OK
OK
TIMING
2
PROGRAMMING
Select and modify the parameter from the list:
-
1 PAUSE TIME
0-30s
-
2 NIGHT PAUSE TIME 0-240s
-
3 NIGHT SENSOR DELAY 0-240S
Default CF1 CF2 CF2 CF4 CF5
PAUSE TIME
2 2 2 2 --
NIGHT PAUSE TIME
10 10 10 10 --
NIGHT PAUSE TIME DELAY
10 10 10 10 --
■
4 ENERGY SAVING
OK
OK
ENERGY SAVING
2
PROGRAMMING
The Energy Saving is disabled by default
CF1,CF2
. Available options are:
-
ENABLED
-
DISABLED
Default CF1 CF2 CF2 CF4 CF5
Energy Saving
Disabled
■
5 BATTERY KIT
OK
OK
BATTERY KIT
2
PROGRAMMING
Summary of Contents for A1000
Page 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Page 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Page 110: ...A1000 110 53221004 Rev A...
Page 114: ...A1000 114 53221004 Rev A...
Page 115: ...Translation of the original instructions ENGLISH...