21.4 CLEANING
F
Before any maintenance operation, disconnect the mains power supply
and disconnect the emergency battery.
!
Before starting to clean, wait for the components subject to overheating
to cool down.
DO NOT use detergents on optical devices and electronic displays (e.g.
photocell lenses).
Do not moisten parts. In particular, do not moisten electrical connections
and components in any way.
NEVER use direct water and compressed air jets neither for cleaning nor
drying.
Ensure all components are dry after cleaning.
Use clean soft cloths to remove dust. Moisten the cloth to remove
dirt. Dry parts with clean, dry and soft cloths.
For parts that are hard to reach, use brushes with soft bristles.
Cleaning products for plastic material parts
With the exception of optical devices and electronic displays, water
and neutral detergent solutions are allowed (in the concentration
indicated by the manufacturer). Use detergents at ambient tempera-
ture (max. 30°C).
DO NOT use alkaline, acid or base solutions, benzene, acetic acid or
solvents of any kind: these products may damage the surfaces of
the materials.
Cleaning products of steel or aluminium parts
Water and neutral detergent solutions are allowed (in the concentra-
tion indicated on the detergent packaging). 95% methylated spirit
diluted at 50%. In case of oily dirt, use 70% solutions of isopropyl
alcohol.
DO NOT use solutions of acetic acid, acid or basic solutions or ethyl
alcohol.
21.5 FUNCTIONAL CHECKS
!
Connect power supply and emergency battery only after tidying up the
area.
In case of failures or malfunctions, please refer to
66
and
70
.
Command some movements to check correct operation:
-
movements correctly executed, according to logics and settings
-
regular and smooth leaf movement
-
end of run slowing down correctly executed
-
approaching the opening and closing stops without impact
-
regular operation of motor block on Motor_1 (if present)
-
working efficiency of emergency battery: disconnect the mains
power supply and ensure that the door opens and remains open
(safety condition)
-
efficiency of safety detectors (the radar field must be free and
adequately sized with respect to passage flow)
-
operation of EMERGENCY button (if present) and any other ac-
cessories installed.
22. WASTE DISPOSAL
After taking down the automation, dispose of it in compliance with
the material disposal regulations in force.
Li
WARNING
The batteries and electronic components must not be disposed of with
household waste but delivered to authorised disposal and recycling
centres.
Summary of Contents for A1000
Page 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Page 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Page 110: ...A1000 110 53221004 Rev A...
Page 114: ...A1000 114 53221004 Rev A...
Page 115: ...Translation of the original instructions ENGLISH...