A1000
91
532210 04 - Rev.A
Tr
ansla
tion of the original instruc
tions
ENGLISH
Default CF1 CF2 CF2 CF4 CF5
LOCK TYPE
XB LOCK
FUNCTION
DISABLED
MONITORING KIT
DISABLED
BATTERY OPERATION
STANDARD
■
7 INSTALLATION
OK
OK
INSTALLATION
2
PROGRAMMING
1 Motor Rotation
The default motor rotation is standard Available options are:
-
STANDARD
-
NON-STANDARD
2 Double Motor Kit
Specifies if the double motor kit is enabled or not.
-
ENABLED
-
DISABLED
3 Start SETUP
This command requires confirmation to perform SETUP.
!
Follow the procedure indicated in
53
.
4 INPUT status
The display shows active inputs. In the example safety sensor S2 is on:
INPUT STATUS
IN4
O2
FSW
OK
IN1
S1
MR
IN2
S2
E1
IN3
O1
E2
5 DOOR status
The display shows what status the door is in:
-
CLOSED ( 00)
- OPENING
(01)
- OPEN
(02)
- PAUSED
(03)
-
NIGHT PAUSE (04)
- CLOSING
(05)
- EMERGENCY
(06)
- MANUAL
(07)
- NIGHT
(08)
-
AUX OPENING (09)
- BOARD
TEST
(10)
- STOPPED
(11)
- SAFETIES
TEST
(12)
- ERROR
(13)
-
SERIOUS ERROR (15)
-
SETUP IN PROGRESS (L0, L1.....)
6 Other board data
The display shows:
-
V_MAIN (input voltage to the board in Volts)
-
V_BATT (battery voltage in Volts)
-
V_ACC (accessories voltage in Volts)
-
I_MOT (current absorbed by the motor in Amperes)
-
POS (leaf position in cm)
Default CF1 CF2 CF2 CF4 CF5
MOTOR ROTATION
STANDARD
DOUBLE MOTOR KIT
DISABLED
START SETUP DIS. ENA. DIS. DIS. DIS.
INPUTS STATUS see DISPLAY
DOOR STATUS see DISPLAY
OTHER BOARD DATA see DISPLAY
■
8 INTERCOM
OK
OK
INTERCOM
2
PROGRAMMING
Intercom menu list:
1. FUNCTION
2. MASTER / SLAVE
3. REGISTRATION
4. NODE LIST
1 FUNCTION
Defines the type of intercom function:
-
Disabled
-
INTERMODE
-
INTERLOCK
with the opportunity of selecting the following functions:
1. With no memory
2. With memory
2 MASTER / SLAVE
Defines the board function:
-
Master (1)
-
Slave (from 2 to 15)
3 REGISTRATION
On the board configured as the Master it activates the procedure to
recognise any connected boards configured as Slave.
4 NODE LIST
On the board configured as the Master, from this menu all boards
connected and configured as Slave and the relative information can
be displayed.
1. ID
2. Errors
3. Warnings
4. Cycles
Default CF1 CF2 CF2 CF4 CF5
FUNCTION
Disabled
MASTER / SLAVE
1 MASTER
REGISTRATION
see DISPLAY
NODE LIST see DISPLAY
■
9 MISCELLANEOUS
OK
OK
MISCELLANEOUS
2
PROGRAMMING
1 Default Configuration
-
ACTIVE (default configuration active)
-
NO (the configuration has been modified)
To reset all parameters to default settings press the OK button and
confirm.
Summary of Contents for A1000
Page 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Page 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Page 110: ...A1000 110 53221004 Rev A...
Page 114: ...A1000 114 53221004 Rev A...
Page 115: ...Translation of the original instructions ENGLISH...