![background image](http://html2.mh-extra.com/html/faac/a1000/a1000_user-manual_3115220029.webp)
A1000
29
532210 04 - Rev.A
35
15
38
16
22
25
20
4
5
40
2
1
3
26
27
28
1
1
35
15
16
20
25
22
26
4
1
3
2
4
4
4
3
4
2
4
1
Tr
ansla
tion of the original instruc
tions
ENGLISH
9. INSTALLING THE LEAVES
RISKS
PERSONAL PROTECTIVE EQUIPMENT
REQUIRED TOOLS
8
6
For manual lifting, there should be 1 person for every 20 kg to be lifted.
9.1 MOUNTING THE LOWER SHOES
SHOE WITH TK50
BRACKET
For fastening to the wall or the fixed leaf
26
.
-
use suitable screws (not provided).
TK50
SWIVEL SHOE
For fastening to the floor
27
.
-
use suitable screws (not provided).
SHOE WITH TK20
BRACKET
For fastening to the fixed leaf
28
.
-
use suitable screws (not provided).
!
Check leaf verticality.
When the leaf is open or closed, the shoe must be fully inside the lower
leaf profile.
The distance between the shoe and the lower profile must be 4mm (
ref.
4
26
-
27
-
28
).
Summary of Contents for A1000