JET 500  | JET 750 |  JET 1000L

SAFETY MEASURES

Read carefully the operating instructions 

before assembling and starting. The appli-

ance must not be used by operators who 

are not thoroughly acquainted with the 

instructions handbook (operating instruc-

tions). Moreover, the appliance must not be 

used by persons under the age of 16.

 

f

The user is liable towards third parties in the area 

where the appliance is in operation.

 

f

Before starting it is necessary to make sure that 

the necessary electrical protection measures, are 

provided by means of a test carried out by a spe-

cialist.

While the pump is operating no operators 

have to be in the liquid to be pumped.

The pump may be connected only by means 

of a safety switch for fault currents, with 

a rated opening current up to 30 mA and 

a socket with an earth contact installed in 

compliance with the regulations. Protec-

tion: at least 10 Amps.

Operation in swimming pools and garden ponds is 

not recommended.

For other operation, the provisions in conformity 

with the standard VDE 0100 part 702 must be re-

spected.

 

CAUTION: Before checking, unplug the 

pump from the mains!

 

f

Replacing the power supply cable requires using 

special  tools  and  therefore  you  must  address  to 

the authorized after-sales service. 

 

f

The  noise  (continuous  equivalent  in  dbA)  of  the 

motor-driven pumps is less or equal (≤) to 70 dbA. 

 

f

The voltage indicated on the pump’ s rating plate 

must correspond to the available mains voltage.

 

f

The temperature of the liquid conveyed must not 

exceed 35°C.

 

f

Never attempt to lift or move the pump by stretch-

ing the power-supply cable whilst it is plugged into 

the mains.

 

f

Make sure that the plugged electrical connections 

are in an area safe from flooding and are protect-

ed from humidity.

 

f

Before use it is necessary to check that the plug 

and the mains connection line are not damaged.

 

f

Unplug  from  the  mains  before  performing  any 

work on the pump.

 

f

Avoid directly exposing the pump to the jet of water.

 

f

The user is responsible for complying with the lo-

cal regulations concerning assembly and safety.

 

f

The user by taking appropriate measures (e.g. install-

ing an alarm, reserve pump and the like) will have to 

exclude the possibility of indirect damage caused by 

flooding premises due to failure of the pump.

 

f

In the event of the pump failing, repair work may 

only be carried out by the repair workshops of the 

technical service. Only genuine spare parts must 

ENGLISH

be used.

 

f

It  is  notified  that  in  conformity  with  the  law  on 

product  liability  we  cannot  be  held  responsible 

for the damage caused by our appliance:

1.  Because of improper repairs not carried out by 

the  personnel  of  the  assistance  points  autho-

rized by us; or

2. 

If genuine spare parts are not used to replace 

parts; or

3. 

If  the  indications  and  provisions  given  in  the 

instructions handbook are not complied with.

The same provisions hold for the accessories.

RESISTANCE

This  pump  should  not  be  used  to  convey  inflam-

mable, combustible or explosive liquids.

TECHNICAL DATA

Article Number

42924

42925 42926

Model

JET 

500

JET 

750

JET 

1000L

Voltage

V

220-

230

220-

230

220-

230

Hz

50

50

50

Output power

hp

0,50

0,75

1,00

W

370

550

750

Input power

W

500

750

1000

Sound power 

level

dB(A)

75

75

75

Max pressure

bar

4,20

4,60

5,00

Max head

m

42

46

50

Max flow

m

3

/h

2,4

2,7

3,3

DN

1

inch

1

1

1

2

inch

1

1

1

Stator length

mm

63#

71#

71#

L70

L62

L80

Weight

Kg

10,8

12,15

14,45

Motor

Speed of rota-

tion

rpm

2.850

2.850

2.850

Protection

IP44

IP44

IP44

Insulation Class

B

B

B

Continuous Duty

S1

S1

S1

Internal Thermal 

Protector

USE

 

f

For irrigation and watering of lawns, gardens, vege-

table patches, etc.

Summary of Contents for JET 500

Page 1: ...ORIGINAL INSTRUCTIONS EN NOTICE ORIGINALE FR ISTRUZIONI ORIGINALI IT EL ORIGINALNO UPUTSTVO ZA RAD SR INSTRUC IUNI DE FOLOSIRE ORIGINALE RO BG ORIGINALNE UPUTE ZA RAD HR JET 500 JET 750 JET 1000L...

Page 2: ...FR POMPE A JET A AUTO AMORCAGE 06 IT ELETTROPOMPA AUTOADESCANTE 08 EL 10 SR SAMOUSISNA JET PUMPA 12 HR MLAZNA CRPKA SA SAMOPUNJENJEM 14 RO POMP DE JET CU EVACUARE AUTOMAT 16 BG 18 TROUBLESHOOTING R SO...

Page 3: ...English 3 www ffgroup tools com JET 500 JET 750 JET 1000L...

Page 4: ...rom flooding and are protect ed from humidity f f Before use it is necessary to check that the plug and the mains connection line are not damaged f f Unplug from the mains before performing any work o...

Page 5: ...ng back on If there is a risk of frost the pump has to be emp tied completely When the pump is not going to be used for a long time for instance in the winter period it is recommended to rinse out the...

Page 6: ...idit f f Avant l utilisation v rifiez si la ligne de branche ment au r seau et la prise sont endommag es f f D branchez la prise lectrique avant toute inter vention sur la pompe f f Evitez d exposer l...

Page 7: ...partie hy draulique rincer tout l int rieur remonter soigneu sement remettre les filtres correctement et effec tuer la mise en service En cas de risque de gel la pompe doit tre com pl tement vid e Av...

Page 8: ...e siano protette dall umidit f f Prima dell uso occorre verificare che la linea di allacciamento alla rete e la spina non siano dan neggiate f f Disinserire la spina della rete prima di eseguire qual...

Page 9: ...ntare accuratamente ripristinare i filtri in modo corretto ed effettuare la messa in funzione In caso di pericolo di gelo la pompa deve essere svuotata completamente Prima di un lungo periodo di inuti...

Page 10: ...f f f f f f 1 2 3 42924 42925 42926 JET 500 JET 750 JET 1000L V 220 230 220 230 220 230 Hz 50 50 50 hp 0 50 0 75 1 00 W 370 550 750 W 500 750 1000 dB A 75 75 75 bar 4 20 4 60 5 00 m 42 46 50 m3 h 2 4...

Page 11: ...11 www ffgroup tools com JET 500 JET 750 JET 1000L B B B S1 S1 S1 f f f f f f 30 2002 96...

Page 12: ...da li su utika i mre ni priklju ni vod o te eni f f Isklju ite iz struje pre obavljanja bilo kakvih radova na pumpi f f Izbegavajte direktno izlaganje pumpe mlazu vode f f Korisnik je odgovoran za po...

Page 13: ...od mraza pumpu treba potpuno isprazniti Kada se pumpa ne koristi u du em preriodu na primer tokom zime preporu uje se da je isperete temeljno vodom potpuno ispraznite i dr ite na suvom mestu Pre pono...

Page 14: ...u o te eni f f Iskop ajte iz elektri ne mre e prije obavljanja radova na crpki f f Izbjegavajte neposredno izvrgavanje crpke mlazu vode f f Korisnik je odgovoran za kori tenje u skladu s lokal nim pro...

Page 15: ...klju ivanja Ako postoji rizik od zamrzavanja crpku je potreb no potpuno isprazniti Ako se crpka ne e koristiti dulje vrijeme primjeri cetijekomzime preporu ujemodadobroisperete crpku vodom potpuno je...

Page 16: ...iuni electrice din priz sunt ntr o zon ferit de riscul de inunda ii i sunt protejate de umiditate f f naintedeutilizareestenecesars verifica idac te cherul i circuitul de alimentare nu sunt deteriorat...

Page 17: ...i cl ti i bine interiorul reasambla i cu aten ie i remonta i filtrele n mod corect nainte s porni i din nou pompa Dac exist unriscde nghe pompatrebuiegolit integral C nd pompa nu va fi folosit o perio...

Page 18: ...f f f f f f f f f f f f f f f 1 2 3 42924 42925 42926 JET 500 JET 750 JET 1000L V 220 230 220 230 220 230 Hz 50 50 50 hp 0 50 0 75 1 00 W 370 550 750 W 500 750 1000 dB A 75 75 75 bar 4 20 4 60 5 00 m...

Page 19: ...19 www ffgroup tools com JET 500 JET 750 JET 1000L rpm 2 850 2 850 2 850 IP44 IP44 IP44 B B B S1 S1 S1 f f f f f f 30 2002 96 EO OEEO...

Page 20: ...and replace the worn parts FRAN AIS R SOLUTION DES PROBL MES PROBL ME CAUSES REMEDIES Le moteur ne d marre pas Absence alimentation lectrique Couronne pompe bloqu e Thermostat d branch V rifier l ali...

Page 21: ...nte Valv aspir non ermetica Filtro aspirazione sporco Superata la max altezza di aspi razione Mettere in acqua la valvola aspirante min 30cm Versare acqua nel raccordo aspir Verificare la tenuta del t...

Page 22: ...vi e velik Usisna ru ica je prljava Nivo vode brzo opada Brzinu protoka pumpe smanjuju strana tela Proverite pritisak usisne strane O istite usisnu ru icu Spustite jo ni e usisni ventil O istite pumpu...

Page 23: ...pirare nu este ermetic Filtrul de aspira ie este murdar Dep irea n l imii maxime de aspira ie A se pune n ap supapa de aspira ie min 30 cm A se turna ap n racordul de aspira ie Se verifica etanseitate...

Page 24: ...navedeni proizvo di odgovaraju svim doti nim odredbama naknadno navedenih smernica u uredaba i da su u skladu sa slede im standardima SAMOUSISNA JET PUMPA Broj predmeta HR EU IZJAVA O SUKLADNOSTI Pod...

Page 25: ...19300 Aspropyrgos Greece Loudovikos Tsirigiotis Operations Engineering FF GROUP TOOL INDUSTRIES S A 19300 Aspropyrgos Greece 3 12 2018 FR Dossier technique aupr s de IT Fascicolo tecnico presso EL SR...

Page 26: ...26 JET 500 JET 750 JET 1000L...

Page 27: ...27 www ffgroup tools com JET 500 JET 750 JET 1000L...

Page 28: ...www ffgroup tools com info ffgroup toolindustries com 30 210 55 98 400 19300 Athens Greece 9 5 Km Attiki Odos Aspropyrgos FF GROUP TOOL INDUSTRIES...

Reviews: