background image

EDMT331529A

RXYMQ4-6AVE

RXYMQ8/9AY1

Heat Pump  50 Hz

Summary of Contents for VRV IV-S Series

Page 1: ...EDMT331529A RXYMQ4 6AVE RXYMQ8 9AY1 Heat Pump 50 Hz...

Page 2: ......

Page 3: ...Ceiling Mounted Duct Type 131 Ceiling Mounted Duct Type 157 Ceiling Mounted Duct Type 197 Ceiling Suspended Type 211 Wall Mounted Type 227 Floor Standing Type Concealed Floor Standing Type 243 Floor S...

Page 4: ...other 50 Hz countries of Latin America New lineup of outdoor units Sep 2015 EDMT331529A H P 50 Hz RXYMQ4 6AVE RXYMQ8 9AY1 Argentina Chile Uruguay and other 50 Hz countries of Latin America Revision f...

Page 5: ...2 1 Indoor Units 6 2 2 Outdoor Units 8 2 3 Air Treatment Equipment 8 3 Nomenclature 9 4 Capacity Range 12 4 1 Capacity Range for VRV Indoor Units Only 12 4 2 Capacity Range for Mixed Combination of V...

Page 6: ...25S 32S 40S 50S 63S 80S 100S 125S VM Ceiling Mounted Cassette Round Flow Type FXFQ 25LU 32LU 40LU 50LU 63LU 80LU 100LU 125LU V1 Ceiling Mounted Cassette Compact Multi Flow Type FXZQ 20M 25M 32M 40M 5...

Page 7: ...ing Data ED71 613 VE 1 phase 220 240 220V 50 60Hz Capacity range 2 0kW 2 5kW 3 5kW 5 0kW 6 0kW 7 1kW Power supply Standard Capacity index 20 25 35 50 60 71 Slim Ceiling Mounted Duct Type CDXS 25EA 35E...

Page 8: ...type FXFQ LU Ceiling mounted duct type FXMQ MA Ceiling mounted cassette Compact multi flow type FXZQ M Ceiling suspended type FXHQ MA 4 way flow ceiling suspended type FXUQ A Wall mounted type FXAQ P...

Page 9: ...ts with Connection to BP Units BP Units Slim ceiling mounted duct type 700 mm width type CDXS EA Wall mounted type FTXS D FTXS E Slim ceiling mounted duct type 900 1 100 mm width type FDXS C Wall moun...

Page 10: ...External Appearance EDMT331529A 8 General Information 2 2 Outdoor Units 2 3 Air Treatment Equipment RXYMQ4 5AVE RXYMQ6AVE RXYMQ8 9AY1 Heat reclaim ventilator VAM series VAM GJ...

Page 11: ...25 14 0 kW 5 HP 250 28 0 kW 10 HP Refrigerant Q R410A Shape F Ceiling Mounted Cassette Round Flow with Sensing Round Flow Z Ceiling Mounted Cassette Compact Multi Flow U 4 Way Flow Ceiling Suspended C...

Page 12: ...cooling capacity kW at 50 Hz 10 Grade and refrigerant symbol S Inverter High grade model R410A G Inverter Extra high grade model R410A Type K Inverter cooling only X Inverter heat pump Shape T Wall mo...

Page 13: ...design category Capacity indication Conversion to kW Horsepower 4 11 2 kW 4 HP 6 16 0 kW 6 HP 9 24 0 kW 9 HP Refrigerant Q R410A Shape M Single outdoor unit Type Y Heat Pump Series category X Inverter...

Page 14: ...n with other indoor units is not permitted Combination ratio Total capacity index of the indoor units Capacity index of the outdoor units Type Min combination ratio Max combination ratio Types of conn...

Page 15: ...permitted Combination ratio Total capacity index of the indoor units Capacity index of the outdoor units Type Min combination ratio Max combination ratio Type of connected indoor units VRV and Reside...

Page 16: ...type and size based on limitation of combination ratio Correct for cooling heating capacity of the outdoor unit by the following items VRV system selection is complete Confirm that the number of indo...

Page 17: ...valent pipe length 30m Model Capacity indication Indoor air temp 14 0 CWB 16 0 CWB 18 0 CWB 19 0 CWB 20 0 CWB 22 0 CWB 24 0 CWB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB TC SHC TC SHC TC SHC TC...

Page 18: ...VRV Indoor Units Capacity range 2 2kW 2 8kW 3 6kW 4 5kW 5 6kW 7 1kW 8 0kW 9 0kW 11 2kW 14 0kW 16 0kW 22 4kW 28 0kW Power supply Standard 0 8HP 1HP 1 25HP 1 6HP 2HP 2 5HP 3HP 3 2HP 4HP 5HP 6HP 8HP 10H...

Page 19: ...ted capacity of RXYMQ8AY1 C by using K1 and K2 Corrected capacity of RXYMQ8AY1 C B K1 K2 add defrost correction factor for heating capacity 21 43 0 95 1 006 20 24 kW If the corrected capacity C is the...

Page 20: ...l indoor units correct the capacity of VRV indoor units for Indoor air temperature and Evaporating temperature Te 9 C In case design temperature of the indoor air falls between temperatures listed in...

Page 21: ...0 833 0 855 SHF 1 124 1 176 1 118 1 094 1 074 1 053 1 048 FXDQ32PBVE FXDQ32PBVET TC 0 688 0 703 0 754 0 770 0 788 0 818 0 840 SHF 1 130 1 171 1 122 1 101 1 083 1 065 1 055 FXDQ40NBVE FXDQ40NBVET TC 0...

Page 22: ...P 4HP 5HP 6HP 8HP 10HP Capacity index 20 25 31 25 40 50 62 5 71 80 100 125 140 200 250 Slim Ceiling Mounted Duct Type FXDQ PBVE 20PB 25PB 32PB VE Model RXYMQ4AVE RXYMQ5AVE RXYMQ6AVE RXYMQ8AY1 RXYMQ9AY...

Page 23: ...g capacity Capacity correction factor 0 95 Te 9 C RXYMQ8AY1 Cooling capacity Capacity correction factor 0 90 Te 9 C Calculate the capacity in case combination ratio 104 In case correction factor 0 95...

Page 24: ...ity of RXYMQ8AY1 C by using K1 and K2 Corrected capacity of RXYMQ8AY1 C B K1 K2 add defrost correction factor for heating capacity 17 7 0 95 1 006 16 7 kW If the corrected capacity C is the same or gr...

Page 25: ...Mounted Cassette Compact Multi Flow Type 61 FXUQ A 4 Way Flow Ceiling Suspended Type 81 FXCQ M Ceiling Mounted Cassette Double Flow Type 93 FXKQ MA Ceiling Mounted Cassette Corner Type 115 FXDQ PB FXD...

Page 26: ...EDMT331529A 24 Indoor Units FXLQ MA FXNQ MA Floor Standing Type Concealed Floor Standing Type 243 FXVQ N Floor Standing Duct Type 269...

Page 27: ...agrams 31 4 Wiring Diagrams 32 5 Electric Characteristics 33 6 Safety Devices Setting 34 7 Capacity Tables 35 7 1 Cooling Capacity 35 7 2 Heating Capacity 35 7 3 Correction Factor for Te 9 C 36 8 Soun...

Page 28: ...orbing thermal insulation material Polyurethane form Polyurethane form Polyurethane form Polyurethane form Piping connections Liquid pipes mm 6 4 Flare connection 6 4 Flare connection 6 4 Flare connec...

Page 29: ...bing thermal insulation material Polyurethane form Polyurethane form Polyurethane form Polyurethane form Piping connections Liquid pipes mm 9 5 Flare connection 9 5 Flare connection 9 5 Flare connecti...

Page 30: ...Dimensions EDMT331529A 28 FXFQ S 2 Dimensions FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM Unit mm 3D084388...

Page 31: ...EDMT331529A Dimensions FXFQ S 29 2 FXFQ63SVM FXFQ80SVM Unit mm 3D084389...

Page 32: ...Dimensions EDMT331529A 30 FXFQ S FXFQ100SVM FXFQ125SVM Unit mm 3D084390...

Page 33: ...s FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM Refrigerant pipe connection port diameters mm Model Gas Liquid FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM 12 7 6 4 FXFQ...

Page 34: ...Wiring Diagrams EDMT331529A 32 FXFQ S 4 Wiring Diagrams FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM 3D084349...

Page 35: ...EDMT331529A Electric Characteristics FXFQ S 33 2 5 Electric Characteristics FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM 4D084422...

Page 36: ...SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM Printed circuit board fuse 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A Drain pum...

Page 37: ...0 0 CWB 22 0 CWB 24 0 CWB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC FXFQ25SVM 25 1 9 2 0 2 3 2 3 2 6 2 5 2 8 2 5 2 8 2 5 2 9 2 4 3 0 2 4 FXFQ32S...

Page 38: ...898 SHF 1 101 1 136 1 099 1 085 1 072 1 052 1 038 FXFQ50SVM TC 0 662 0 733 0 788 0 807 0 825 0 855 0 878 SHF 1 201 1 143 1 100 1 084 1 068 1 045 1 030 FXFQ63SVM TC 0 667 0 736 0 790 0 808 0 827 0 856...

Page 39: ...EDMT331529A Sound Levels FXFQ S 37 2 8 Sound Levels FXFQ25SVM FXFQ32SVM FXFQ40SVM 4D084359 4D084360...

Page 40: ...Sound Levels EDMT331529A 38 FXFQ S FXFQ50SVM FXFQ63SVM 4D084361 4D084362...

Page 41: ...EDMT331529A Sound Levels FXFQ S 39 2 FXFQ80SVM FXFQ100SVM 4D084363 4D084364...

Page 42: ...Sound Levels EDMT331529A 40 FXFQ S FXFQ125SVM 4D084365...

Page 43: ...EDMT331529A Centre of Gravity FXFQ S 41 2 9 Centre of Gravity FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM Unit mm 4D052237Q...

Page 44: ...harge outlet KDBHQ55B140 Panel spacer KDBP55H160FA Filter related High efficiency filter unit 65 KAFP556B80 KAFP556B160 90 KAFP557B80 KAFP557B160 Replacement highefficiency filter 65 KAFP552B80 KAFP55...

Page 45: ...49 4 Wiring Diagrams 50 5 Electric Characteristics 51 6 Safety Devices Setting 52 7 Capacity Tables 53 7 1 Cooling Capacity 53 7 2 Heating Capacity 53 7 3 Correction Factor for Te 9 C 54 8 Sound Leve...

Page 46: ...g connections Liquid pipes mm 6 4 Flare connection 6 4 Flare connection 6 4 Flare connection 6 4 Flare connection Gas pipes mm 12 7 Flare connection 12 7 Flare connection 12 7 Flare connection 12 7 Fl...

Page 47: ...Piping connections Liquid pipes mm 9 5 Flare connection 9 5 Flare connection 9 5 Flare connection 9 5 Flare connection Gas pipes mm 15 9 Flare connection 15 9 Flare connection 15 9 Flare connection 1...

Page 48: ...Dimensions EDMT331529A 46 FXFQ LU 2 Dimensions FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 Unit mm 3D081556A...

Page 49: ...EDMT331529A Dimensions FXFQ LU 47 3 FXFQ63LUV1 FXFQ80LUV1 Unit mm 3D078813F...

Page 50: ...Dimensions EDMT331529A 48 FXFQ LU FXFQ100LUV1 FXFQ125LUV1 Unit mm 3D078815F...

Page 51: ...LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1 Refrigerant pipe connection port diameters mm Model Gas Liquid FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 12 7 6 4...

Page 52: ...Wiring Diagrams EDMT331529A 50 FXFQ LU 4 Wiring Diagrams FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1 3D080879...

Page 53: ...EDMT331529A Electric Characteristics FXFQ LU 51 3 5 Electric Characteristics FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1 4D060238H...

Page 54: ...Setting Model FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1 Printed circuit board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan...

Page 55: ...22 0 CWB 24 0 CWB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC FXFQ25LUV1 25 1 9 1 9 2 3 2 3 2 6 2 6 2 8 2 8 2 8 2 8 2 9 2 7 3 0 2 6 FXFQ32LUV1 32...

Page 56: ...875 SHF 1 165 1 152 1 106 1 090 1 077 1 053 1 036 FXFQ50LUV1 TC 0 662 0 692 0 755 0 779 0 800 0 834 0 858 SHF 1 173 1 183 1 121 1 096 1 079 1 054 1 035 FXFQ63LUV1 TC 0 664 0 693 0 756 0 781 0 803 0 8...

Page 57: ...EDMT331529A Sound Levels FXFQ LU 55 3 8 Sound Levels FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 4D060231D 4D060232D...

Page 58: ...Sound Levels EDMT331529A 56 FXFQ LU FXFQ50LUV1 FXFQ63LUV1 4D060233D 4D060234E...

Page 59: ...EDMT331529A Sound Levels FXFQ LU 57 3 FXFQ80LUV1 FXFQ100LUV1 4D060235D 4D060236C...

Page 60: ...Sound Levels EDMT331529A 58 FXFQ LU FXFQ125LUV1 4D060237D...

Page 61: ...EDMT331529A Centre of Gravity FXFQ LU 59 3 9 Centre of Gravity FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1 FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1 Unit mm C 4D052237Q...

Page 62: ...ilter unit 65 KAFP556B80 KAFP556B160 90 KAFP557B80 KAFP557B160 Replacement highefficiency filter 65 KAFP552B80 KAFP552B160 90 KAFP553B80 KAFP553B160 Filter chamber KDDFP55B160 Replacement long life fi...

Page 63: ...stics 67 6 Safety Devices Setting 68 7 Capacity Tables 69 7 1 Cooling Capacity 69 7 2 Heating Capacity 69 7 3 Correction Factor for Te 9 C 70 8 Air Velocity and Temperature Distributions Reference Dat...

Page 64: ...amed polystyrene Foamed polyethylene Piping connections Liquid pipes mm 6 4 Flare connection 6 4 Flare connection 6 4 Flare connection Gas pipes mm 12 7 Flare connection 12 7 Flare connection 12 7 Fla...

Page 65: ...cooling and heating Sound absorbing thermal insulation material Foamed polystyrene Foamed polyethylene Foamed polystyrene Foamed polyethylene Piping connections Liquid pipes mm 6 4 Flare connection 6...

Page 66: ...Dimensions EDMT331529A 64 FXZQ M 2 Dimensions FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE Unit mm C 3D039005E...

Page 67: ...iagrams FXZQ M 65 4 3 Piping Diagrams FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE 4D040157B Refrigerant pipe connection port diameters mm Model Gas Liquid FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE...

Page 68: ...Wiring Diagrams EDMT331529A 66 FXZQ M 4 Wiring Diagrams FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE C 3D064843...

Page 69: ...EDMT331529A Electric Characteristics FXZQ M 67 4 5 Electric Characteristics FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE C 4D040159B...

Page 70: ...XZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE Printed circuit board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protector C OFF 130 5 ON 83 20 OFF 130 5...

Page 71: ...the corrected capacity of the VRV system satisfies the required heat load 2 shows rated condition Model Capacity indication Indoor air temp 14 0 CWB 16 0 CWB 18 0 CWB 19 0 CWB 20 0 CWB 22 0 CWB 24 0 C...

Page 72: ...1 FXZQ25MVE TC 0 655 0 695 0 757 0 779 0 797 0 832 0 860 SHF 1 196 1 179 1 118 1 095 1 080 1 052 1 031 FXZQ32MVE TC 0 656 0 694 0 757 0 779 0 797 0 833 0 876 SHF 1 194 1 180 1 119 1 095 1 080 1 051 1...

Page 73: ...9A Air Velocity and Temperature Distributions Reference Data FXZQ M 71 4 8 Air Velocity and Temperature Distributions Reference Data FXZQ20MVE FXZQ25MVE Cooling FXZQ20MVE FXZQ25MVE Heating 4D039738D 4...

Page 74: ...Air Velocity and Temperature Distributions Reference Data EDMT331529A 72 FXZQ M FXZQ32MVE Cooling FXZQ32MVE Heating 4D040188A 4D040191A...

Page 75: ...EDMT331529A Air Velocity and Temperature Distributions Reference Data FXZQ M 73 4 FXZQ40MVE Cooling FXZQ40MVE Heating 4D040189A 4D040192A...

Page 76: ...Air Velocity and Temperature Distributions Reference Data EDMT331529A 74 FXZQ M FXZQ50MVE Cooling FXZQ50MVE Heating 4D040190A 4D040193A...

Page 77: ...EDMT331529A Sound Levels FXZQ M 75 4 9 Sound Levels 9 1 230V 50Hz FXZQ20MVE FXZQ25MVE FXZQ32MVE 4D040274A 4D040285A...

Page 78: ...Sound Levels EDMT331529A 76 FXZQ M FXZQ40MVE FXZQ50MVE 4D040286A 4D040287A...

Page 79: ...EDMT331529A Sound Levels FXZQ M 77 4 9 2 240V 50Hz FXZQ20MVE FXZQ25MVE FXZQ32MVE 4D040492A 4D040491A...

Page 80: ...Sound Levels EDMT331529A 78 FXZQ M FXZQ40MVE FXZQ50MVE 4D040490A 4D040293A...

Page 81: ...EDMT331529A Centre of Gravity FXZQ M 79 4 10 Centre of Gravity FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE 4D040158A Unit mm...

Page 82: ...l Accessories for Controls Refer to page 526 Item Model FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE Decoration panel BYFQ60B3W1 Sealing material of air discharge outlet KDBH44BA60 Panel spacer K...

Page 83: ...Diagrams 84 4 Wiring Diagrams 85 5 Electric Characteristics 86 6 Safety Devices Setting 87 7 Capacity Tables 88 7 1 Cooling Capacity 88 7 2 Heating Capacity 88 7 3 Correction Factor for Te 9 C 89 8 S...

Page 84: ...094 918 741 Drive Direct drive Direct drive Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Insulation Heat insulation Heat res...

Page 85: ...EDMT331529A Dimensions FXUQ A 83 5 2 Dimensions FXUQ71AVEB FXUQ100AVEB Unit mm 3D080135...

Page 86: ...Piping Diagrams EDMT331529A 84 FXUQ A 3 Piping Diagrams FXUQ71AVEB FXUQ100AVEB Refrigerant pipe connection port diameters C 4D034245L mm Model Gas Liquid FXUQ71AVEB FXUQ100AVEB 15 9 9 5...

Page 87: ...EDMT331529A Wiring Diagrams FXUQ A 85 5 4 Wiring Diagrams FXUQ71AVEB FXUQ100AVEB 3D079580...

Page 88: ...Electric Characteristics EDMT331529A 86 FXUQ A 5 Electric Characteristics FXUQ71AVEB FXUQ100AVEB 4D080216A...

Page 89: ...EDMT331529A Safety Devices Setting FXUQ A 87 5 6 Safety Devices Setting 4D013856M Model FXUQ71AVEB FXUQ100AVEB Fuse 250V 3 15A 250V 3 15A Fan motor thermal fuse C Fan motor thermal protector C...

Page 90: ...acity of the VRV system depends on factors such as the selected model of outdoor units outdoor air temperature and piping length Please confirm that the corrected capacity of the VRV system satisfies...

Page 91: ...WB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB FXUQ71AVEB TC 0 688 0 747 0 797 0 815 0 833 0 862 0 884 SHF 1 166 1 134 1 097 1 083 1 068 1 053 1 039 FXUQ100AVEB TC 0 722 0 756 0 806 0 824 0 840 0...

Page 92: ...Sound Levels EDMT331529A 90 FXUQ A 8 Sound Levels FXUQ71AVEB FXUQ100AVEB 4D080130 4D080131...

Page 93: ...Accessories for Unit C 3D080116A 9 2 Optional Accessories for Controls Refer to page 526 Item Model FXUQ71AVEB FXUQ100AVEB Sealing member of air discharge outlet KDBHP49B140 Decoration panel for air...

Page 94: ...Accessories EDMT331529A 92 FXUQ A...

Page 95: ...haracteristics 103 6 Safety Devices Setting 104 7 Capacity Tables 105 7 1 Cooling Capacity 105 7 2 Heating Capacity 105 7 3 Correction Factor for Te 9 C 106 8 Air Velocity and Temperature Distribution...

Page 96: ...nnection 6 4 Flare connection 6 4 Flare connection 6 4 Flare connection Gas pipes mm 12 7 Flare connection 12 7 Flare connection 12 7 Flare connection 12 7 Flare connection Drain pipe mm VP25 External...

Page 97: ...connection 9 5 Flare connection 9 5 Flare connection 9 5 Flare connection Gas pipes mm 12 7 Flare connection 15 9 Flare connection 15 9 Flare connection 15 9 Flare connection Drain pipe mm VP25 Exter...

Page 98: ...Dimensions EDMT331529A 96 FXCQ M 2 Dimensions FXCQ20MVE BYBC32G W1 Decoration panel FXCQ25MVE BYBC32G W1 Decoration panel FXCQ32MVE BYBC32G W1 Decoration panel Unit mm 3D039405C...

Page 99: ...EDMT331529A Dimensions FXCQ M 97 6 FXCQ40MVE BYBC50G W1 Decoration panel FXCQ50MVE BYBC50G W1 Decoration panel Unit mm 3D039406C...

Page 100: ...Dimensions EDMT331529A 98 FXCQ M FXCQ63MVE BYBC63G W1 Decoration panel Unit mm 3D039407C...

Page 101: ...EDMT331529A Dimensions FXCQ M 99 6 FXCQ80MVE BYBC125G W1 Decoration panel FXCQ125MVE BYBC125G W1 Decoration panel Unit mm 3D039409C...

Page 102: ...FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE Refrigerant pipe connection port diameters C 4D034245L mm Model Gas Liquid FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXC...

Page 103: ...EDMT331529A Wiring Diagrams FXCQ M 101 6 4 Wiring Diagrams FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ63MVE C 3D039558A...

Page 104: ...Wiring Diagrams EDMT331529A 102 FXCQ M FXCQ40MVE FXCQ50MVE FXCQ80MVE FXCQ125MVE C 3D039559A...

Page 105: ...EDMT331529A Electric Characteristics FXCQ M 103 6 5 Electric Characteristics FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE C 4D034243B...

Page 106: ...rinted circuit board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C 152 2 152 2 152 2 152 2 152 2 Fan motor thermal protector C OFF 130 5 ON 90 15 OFF 13...

Page 107: ...9 0 CWB 20 0 CWB 22 0 CWB 24 0 CWB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC FXCQ20MVE 20 1 5 1 4 1 8 1 5 2 1 1 7 2 2 1 7 2 2 1 6 2 3 1 5 2 3 1...

Page 108: ...0 842 SHF 1 147 1 192 1 135 1 108 1 086 1 061 1 041 FXCQ40MVE TC 0 671 0 687 0 748 0 772 0 792 0 821 0 854 SHF 1 167 1 191 1 128 1 101 1 082 1 059 1 035 FXCQ50MVE TC 0 663 0 690 0 753 0 777 0 795 0 83...

Page 109: ...perature Distributions Reference Data FXCQ63MVE Heating Air velocity distribution Discharge angle 60 FXCQ63MVE Heating Temperature distribution Discharge angle 60 Note The standard setup height of the...

Page 110: ...XCQ M FXCQ125MVE Heating Air velocity distribution Discharge angle 60 FXCQ125MVE Heating Temperature distribution Discharge angle 60 Note The standard setup height of the double flow type is 3 m maxim...

Page 111: ...EDMT331529A Sound Levels FXCQ M 109 6 9 Sound Levels FXCQ20MVE FXCQ25MVE FXCQ32MVE 4D034329 4D034330...

Page 112: ...Sound Levels EDMT331529A 110 FXCQ M FXCQ40MVE FXCQ50MVE FXCQ63MVE 4D034331 4D034332...

Page 113: ...EDMT331529A Sound Levels FXCQ M 111 6 FXCQ80MVE FXCQ125MVE 4D034333 4D034334...

Page 114: ...Centre of Gravity EDMT331529A 112 FXCQ M 10 Centre of Gravity FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE Unit mm 4D034788D...

Page 115: ...VE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE Decoration panel BYBC32G W1 BYBC50G W1 BYBC63G W1 BYBC125G W1 Filter related High efficiency filter 65 1 KAFJ532G36 KAFJ532G56...

Page 116: ...Accessories EDMT331529A 114 FXCQ M...

Page 117: ...haracteristics 121 6 Safety Devices Setting 122 7 Capacity Tables 123 7 1 Cooling Capacity 123 7 2 Heating Capacity 123 7 3 Correction Factor for Te 9 C 124 8 Air Velocity and Temperature Distribution...

Page 118: ...ction Gas pipes mm 12 7 Flare connection 12 7 Flare connection 12 7 Flare connection 15 9 Flare connection Drain pipe mm VP25 External dia 32 Internal dia 25 VP25 External dia 32 Internal dia 25 VP25...

Page 119: ...10 760 Ceiling opening 10 Discharge Gas pipe connection Grounding terminal Notes 1 Location of unit s Name plate For main body Bottom part of fan housing inside of Air suction grille For decoration pa...

Page 120: ...mm or more 20mm or more 1500mm or more Required installation space Discharge Gas pipe connection Grounding terminal Notes 1 Location of unit s Name plate For main body Bottom part of fan housing insid...

Page 121: ...iagrams FXKQ MA 119 7 3 Piping Diagrams FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE Refrigerant pipe connection port diameters C 4D034245L mm Model Gas Liquid FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE 12 7 6 4...

Page 122: ...ELAY M1P MOTOR INDOOR FAN MOTOR DRAIN PUMP MOTOR SWING FLAP THERMO SWITCH M1F EMBEDDED A1P A2P C1 F1U HAP K1R K3R KAR KPR M1F M1P M1S Q1M THERMISTOR AIR THERMISTOR COIL FLOAT SWITCH LIMIT SWITCH SWING...

Page 123: ...EDMT331529A Electric Characteristics FXKQ MA 121 7 5 Electric Characteristics FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE 4D037076C...

Page 124: ...l FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE Printed circuit board fuse 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C 146 3 146 3 Fan motor thermal protector C OFF 120 5 ON 105 or less OFF...

Page 125: ...temperature and piping length Please confirm that the corrected capacity of the VRV system satisfies the required heat load 2 shows rated condition Model Capacity indication Indoor air temp 14 0 CWB 1...

Page 126: ...0 851 SHF 1 118 1 176 1 119 1 095 1 076 1 055 1 041 FXKQ32MAVE TC 0 694 0 692 0 751 0 774 0 794 0 821 0 852 SHF 1 118 1 176 1 119 1 095 1 076 1 054 1 041 FXKQ40MAVE TC 0 696 0 691 0 751 0 774 0 794 0...

Page 127: ...ature Distributions Reference Data FXKQ63MAVE Heating Air velocity distribution Lower airflow FXKQ63MAVE Heating Temperature distribution Lower airflow Note The corner type is applicable on a high cei...

Page 128: ...Sound Levels EDMT331529A 126 FXKQ MA 9 Sound Levels FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE 4D037071 4D037072...

Page 129: ...EDMT331529A Sound Levels FXKQ MA 127 7 FXKQ63MAVE 4D037073...

Page 130: ...Centre of Gravity EDMT331529A 128 FXKQ MA 10 Centre of Gravity FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE C 4D037079A Unit mm...

Page 131: ...to page 526 Item Model FXKQ25MAVE FXKQ32MAVE FXKQ40MAVE FXKQ63MAVE Panel related Decoration panel BYK45FJW1 BYK71FJW1 Long life replacement filter KAFJ521F56 KAFJ521F80 Air inlet and air discharge ou...

Page 132: ...Accessories EDMT331529A 130 FXKQ MA...

Page 133: ...ectric Characteristics 143 6 Safety Devices Setting 144 7 Capacity Tables 145 7 1 Cooling Capacity 145 7 2 Heating Capacity 145 7 3 Correction Factor for Te 9 C 146 8 Fan Performances 147 8 1 FXDQ PB...

Page 134: ...62 1 Airflow rate HH H L m min 8 0 7 2 6 4 8 0 7 2 6 4 8 0 7 2 6 4 l s 133 120 106 133 120 106 133 120 106 cfm 282 254 226 282 254 226 282 254 226 4 External static pressure Pa 30 10 30 10 30 10 Driv...

Page 135: ...1 Airflow rate HH H L m min 10 5 9 5 8 5 12 5 11 0 10 0 16 5 14 5 13 0 l s 175 158 141 208 183 166 275 241 216 cfm 371 335 300 441 388 353 583 512 459 4 External static pressure Pa 44 15 44 15 44 15 D...

Page 136: ...Dimensions EDMT331529A 134 FXDQ PB FXDQ NB 2 Dimensions 2 1 FXDQ PB FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE with a drain pump Unit mm 3D049799C...

Page 137: ...EDMT331529A Dimensions FXDQ PB FXDQ NB 135 8 FXDQ20PBVET FXDQ25PBVET FXDQ32PBVET without a drain pump Unit mm 3D050732B...

Page 138: ...Dimensions EDMT331529A 136 FXDQ PB FXDQ NB 2 2 FXDQ NB FXDQ40NBVE FXDQ50NBVE with a drain pump Unit mm 3D045494D...

Page 139: ...EDMT331529A Dimensions FXDQ PB FXDQ NB 137 8 FXDQ63NBVE with a drain pump Unit mm 3D045496E...

Page 140: ...Dimensions EDMT331529A 138 FXDQ PB FXDQ NB FXDQ40NBVET FXDQ50NBVET without a drain pump Unit mm 3D049701B...

Page 141: ...EDMT331529A Dimensions FXDQ PB FXDQ NB 139 8 FXDQ63NBVET without a drain pump Unit mm 3D049702B...

Page 142: ...NBVE FXDQ63NBVE FXDQ20PBVET FXDQ25PBVET FXDQ32PBVET FXDQ40NBVET FXDQ50NBVET FXDQ63NBVET Refrigerant pipe connection port diameters mm Model Gas Liquid FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ5...

Page 143: ...EDMT331529A Wiring Diagrams FXDQ PB FXDQ NB 141 8 4 Wiring Diagrams FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE with a drain pump 3D060547B...

Page 144: ...THE COMBINATION SYSTEM CONFIRM ENGINEERING MATERIALS AND CATALOGS ETC BEFORE CONNECTING 5 WHEN CONNECTING THE INPUT WIRES FROM OUTSIDE FORCED OFF OR ON OFF CONTROL OPERATION CAN BE SELECTED BY REMOTE...

Page 145: ...tric Characteristics FXDQ PB FXDQ NB 143 8 5 Electric Characteristics FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE FXDQ20PBVET FXDQ25PBVET FXDQ32PBVET FXDQ40NBVET FXDQ50NBVET FXDQ...

Page 146: ...VE FXDQ32PBVET FXDQ40NBVE FXDQ40NBVET FXDQ50NBVE FXDQ50NBVET FXDQ63NBVE FXDQ63NBVET Printed circuit board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C Fan motor therma...

Page 147: ...door air temp 14 0 CWB 16 0 CWB 18 0 CWB 19 0 CWB 20 0 CWB 22 0 CWB 24 0 CWB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC FXDQ20PBVE FXDQ20PBVET 20...

Page 148: ...F 1 124 1 176 1 118 1 094 1 074 1 053 1 048 FXDQ32PBVE FXDQ32PBVET TC 0 688 0 703 0 754 0 770 0 788 0 818 0 840 SHF 1 130 1 171 1 122 1 101 1 083 1 065 1 055 FXDQ40NBVE FXDQ40NBVET TC 0 677 0 699 0 75...

Page 149: ...emote controller can be used to switch between HH H and L 2 The airflow is set to standard before leaving the factory It is possible to switch between standard ESP and high ESP by the remote controlle...

Page 150: ...can be used to switch between HH H and L 2 The airflow is set to standard before leaving the factory It is possible to switch between standard ESP and high ESP by the remote controller FXDQ40NBVE FXD...

Page 151: ...EDMT331529A Sound Levels FXDQ PB FXDQ NB 149 8 9 Sound Levels 9 1 FXDQ PB FXDQ20PBVE FXDQ20PBVET FXDQ25PBVE FXDQ25PBVET 4D090841 4D090842...

Page 152: ...Sound Levels EDMT331529A 150 FXDQ PB FXDQ NB FXDQ32PBVE FXDQ32PBVET 4D090844...

Page 153: ...EDMT331529A Sound Levels FXDQ PB FXDQ NB 151 8 9 2 FXDQ NB FXDQ40NBVE FXDQ40NBVET FXDQ50NBVE FXDQ50NBVET 4D090843 4D090845...

Page 154: ...Sound Levels EDMT331529A 152 FXDQ PB FXDQ NB FXDQ63NBVE FXDQ63NBVET 4D090846...

Page 155: ...EDMT331529A Centre of Gravity FXDQ PB FXDQ NB 153 8 10 Centre of Gravity 10 1 FXDQ PB FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ20PBVET FXDQ25PBVET FXDQ32PBVET 4D049300L Unit mm...

Page 156: ...Centre of Gravity EDMT331529A 154 FXDQ PB FXDQ NB 10 2 FXDQ NB FXDQ40NBVE FXDQ50NBVE FXDQ40NBVET FXDQ50NBVET FXDQ63NBVE FXDQ63NBVET 4D043886Q Unit mm 4D043887P Unit mm...

Page 157: ...for Unit C 4D060939C 11 2 Optional Accessories for Controls Refer to page 526 Item Model FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE FXDQ20PBVET FXDQ25PBVET FXDQ32PBVET FXDQ40NBVE FXDQ50NBVE FXDQ40NBVET FXDQ50NB...

Page 158: ...Accessories EDMT331529A 156 FXDQ PB FXDQ NB...

Page 159: ...tics 168 6 Safety Devices Setting 169 7 Capacity Tables 170 7 1 Cooling Capacity 170 7 2 Heating Capacity 170 7 3 Correction Factor for Te 9 C 171 8 Fan Performances 172 9 Airflow Auto Adjustment Char...

Page 160: ...vanized steel plate Galvanized steel plate Galvanized steel plate Dimensions H W D mm 300 550 700 300 550 700 300 550 700 Fan Model Type Sirocco fan Sirocco fan Sirocco fan Motor output Number of unit...

Page 161: ...occo fan Motor output Number of units W 140 1 350 1 350 1 350 1 Airflow rate HH H L m min 16 13 11 18 16 5 15 19 5 17 5 16 25 22 5 20 l s 267 216 183 300 275 250 325 292 267 417 375 333 cfm 565 459 38...

Page 162: ...plate Galvanized steel plate Galvanized steel plate Dimensions H W D mm 300 1 400 700 300 1 400 700 300 1 400 700 Fan Model Type Sirocco fan Sirocco fan Sirocco fan Motor output Number of units W 350...

Page 163: ...EDMT331529A Dimensions FXMQ P 161 9 2 Dimensions FXMQ20PVE FXMQ25PVE FXMQ32PVE Unit mm 3D062541C...

Page 164: ...Dimensions EDMT331529A 162 FXMQ P FXMQ40PVE Unit mm 3D060160H...

Page 165: ...EDMT331529A Dimensions FXMQ P 163 9 FXMQ50PVE Unit mm 3D060159G...

Page 166: ...Dimensions EDMT331529A 164 FXMQ P FXMQ63PVE FXMQ80PVE Unit mm 3D060161H...

Page 167: ...EDMT331529A Dimensions FXMQ P 165 9 FXMQ100PVE FXMQ125PVE FXMQ140PVE Unit mm 3D060162H...

Page 168: ...XMQ32PVE FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE Refrigerant pipe connection port diameters mm Model Gas Liquid FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE 12 7...

Page 169: ...EDMT331529A Wiring Diagrams FXMQ P 167 9 4 Wiring Diagrams FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE C 3D058783F...

Page 170: ...Electric Characteristics EDMT331529A 168 FXMQ P 5 Electric Characteristics FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE C 4D060439D...

Page 171: ...MQ100PVE FXMQ125PVE FXMQ140PVE Printed circuit board fuse 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A Printed circuit board fuse Fan d...

Page 172: ...SHC FXMQ20PVE 20 1 5 1 5 1 8 1 8 2 1 1 9 2 2 1 9 2 2 1 9 2 3 1 8 2 3 1 8 FXMQ25PVE 25 1 9 1 8 2 3 2 0 2 6 2 3 2 8 2 3 2 8 2 2 2 9 2 1 3 0 2 2 FXMQ32PVE 32 2 4 2 1 2 9 2 4 3 4 2 7 3 6 2 8 3 6 2 7 3 7...

Page 173: ...0 863 SHF 1 124 1 151 1 098 1 080 1 067 1 051 1 050 FXMQ50PVE TC 0 674 0 707 0 766 0 788 0 808 0 838 0 861 SHF 1 150 1 157 1 106 1 084 1 069 1 054 1 049 FXMQ63PVE TC 0 677 0 708 0 766 0 791 0 811 0 83...

Page 174: ...Fan Performances EDMT331529A 172 FXMQ P 8 Fan Performances FXMQ20PVE FXMQ25PVE 3D062537A...

Page 175: ...EDMT331529A Fan Performances FXMQ P 173 9 FXMQ32PVE 3D062538A...

Page 176: ...Fan Performances EDMT331529A 174 FXMQ P FXMQ40PVE 3D060456C...

Page 177: ...EDMT331529A Fan Performances FXMQ P 175 9 FXMQ50PVE 3D060457D...

Page 178: ...Fan Performances EDMT331529A 176 FXMQ P FXMQ63PVE 3D060458C...

Page 179: ...EDMT331529A Fan Performances FXMQ P 177 9 FXMQ80PVE 3D060459C...

Page 180: ...Fan Performances EDMT331529A 178 FXMQ P FXMQ100PVE 3D060460C...

Page 181: ...EDMT331529A Fan Performances FXMQ P 179 9 FXMQ125PVE 3D060461C...

Page 182: ...Fan Performances EDMT331529A 180 FXMQ P FXMQ140PVE 3D063787...

Page 183: ...EDMT331529A Airflow Auto Adjustment Characteristics FXMQ P 181 9 9 Airflow Auto Adjustment Characteristics FXMQ20PVE FXMQ25PVE 3D062539A...

Page 184: ...Airflow Auto Adjustment Characteristics EDMT331529A 182 FXMQ P FXMQ32PVE 3D062540A...

Page 185: ...EDMT331529A Airflow Auto Adjustment Characteristics FXMQ P 183 9 FXMQ40PVE 3D060577D...

Page 186: ...Airflow Auto Adjustment Characteristics EDMT331529A 184 FXMQ P FXMQ50PVE 3D060578D...

Page 187: ...EDMT331529A Airflow Auto Adjustment Characteristics FXMQ P 185 9 FXMQ63PVE 3D060579D...

Page 188: ...Airflow Auto Adjustment Characteristics EDMT331529A 186 FXMQ P FXMQ80PVE 3D060580D...

Page 189: ...EDMT331529A Airflow Auto Adjustment Characteristics FXMQ P 187 9 FXMQ100PVE 3D060581D...

Page 190: ...Airflow Auto Adjustment Characteristics EDMT331529A 188 FXMQ P FXMQ125PVE 3D060582D...

Page 191: ...EDMT331529A Sound Levels FXMQ P 189 9 10 Sound Levels FXMQ20PVE FXMQ25PVE FXMQ32PVE 4D062535 4D062536...

Page 192: ...Sound Levels EDMT331529A 190 FXMQ P FXMQ40PVE FXMQ50PVE 4D060446B 4D060428B...

Page 193: ...EDMT331529A Sound Levels FXMQ P 191 9 FXMQ63PVE FXMQ80PVE 4D060447B 4D060429B...

Page 194: ...Sound Levels EDMT331529A 192 FXMQ P FXMQ100PVE FXMQ125PVE 4D060448B 4D060449B...

Page 195: ...EDMT331529A Sound Levels FXMQ P 193 9 FXMQ140PVE 4D063786...

Page 196: ...Centre of Gravity EDMT331529A 194 FXMQ P 11 Centre of Gravity FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE Unit mm C 4D060438C...

Page 197: ...AF372AA160 90 KAF373AA36 KAF373AA56 KAF373AA80 KAF373AA160 Filter chamber KDDF37AA36 KDDF37AA56 KDDF37AA80 KDDF37AA160 Long life replacement filter KAF371AA36 KAF371AA56 KAF371AA80 KAF371AA160 Long li...

Page 198: ...Accessories EDMT331529A 196 FXMQ P...

Page 199: ...01 5 Electric Characteristics 202 6 Safety Devices Setting 203 7 Capacity Tables 204 7 1 Cooling Capacity 204 7 2 Heating Capacity 204 7 3 Correction Factor for Te 9 C 205 8 Fan Performances 206 9 Sou...

Page 200: ...00 kW 25 0 31 5 Casing Colour Galvanized steel plate Galvanized steel plate Dimensions H W D mm 470 1 380 1 100 470 1 380 1 100 Fan Model D13 4G2DA1 2 D13 4G2DA1 2 Type Sirocco fan Sirocco fan Motor o...

Page 201: ...EDMT331529A Dimensions FXMQ MA 199 10 2 Dimensions FXMQ200MAVE FXMQ250MAVE Unit mm C 3D038851A...

Page 202: ...Piping Diagrams EDMT331529A 200 FXMQ MA 3 Piping Diagrams FXMQ200MAVE FXMQ250MAVE Refrigerant pipe connection port diameters C 4D034245L mm Model Gas Liquid FXMQ200MAVE 19 1 9 5 FXMQ250MAVE 22 2...

Page 203: ...EDMT331529A Wiring Diagrams FXMQ MA 201 10 4 Wiring Diagrams FXMQ200MAVE FXMQ250MAVE C 3D039621E...

Page 204: ...Electric Characteristics EDMT331529A 202 FXMQ MA 5 Electric Characteristics FXMQ200MAVE FXMQ250MAVE 4D040330B...

Page 205: ...Setting FXMQ MA 203 10 6 Safety Devices Setting C 3D034597L Model FXMQ200MAVE FXMQ250MAVE Printed circuit board fuse 250V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protector C OFF 135 8 O...

Page 206: ...system depends on factors such as the selected model of outdoor units outdoor air temperature and piping length Please confirm that the corrected capacity of the VRV system satisfies the required hea...

Page 207: ...CWB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB FXMQ200MAVE TC 0 679 0 701 0 762 0 788 0 810 0 836 0 859 SHF 1 136 1 164 1 109 1 085 1 070 1 060 1 051 FXMQ250MAVE TC 0 687 0 717 0 781 0 800 0 815...

Page 208: ...Fan Performances EDMT331529A 206 FXMQ MA 8 Fan Performances FXMQ200MAVE 3D035172...

Page 209: ...EDMT331529A Fan Performances FXMQ MA 207 10 FXMQ250MAVE 3D035173A...

Page 210: ...Sound Levels EDMT331529A 208 FXMQ MA 9 Sound Levels FXMQ200MAVE FXMQ250MAVE 4D035168 4D035169...

Page 211: ...EDMT331529A Centre of Gravity FXMQ MA 209 10 10 Centre of Gravity FXMQ200MAVE FXMQ250MAVE Unit mm 4D035171...

Page 212: ...ssories for Unit C 3D040334D 11 2 Optional Accessories for Controls Refer to page 526 Item Model FXMQ200MAVE FXMQ250MAVE Drain pump kit KDU30L250VE High efficiency filter 65 KAFJ372L280 90 KAFJ373L280...

Page 213: ...tric Characteristics 218 6 Safety Devices Setting 219 7 Capacity Tables 220 7 1 Cooling Capacity 220 7 2 Heating Capacity 220 7 3 Correction Factor for Te 9 C 221 8 Air Velocity and Temperature Distri...

Page 214: ...drive Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Sound absorbing thermal...

Page 215: ...EDMT331529A Dimensions FXHQ MA 213 11 2 Dimensions FXHQ32MAVE Unit mm 3D038855A...

Page 216: ...Dimensions EDMT331529A 214 FXHQ MA FXHQ63MAVE Unit mm 3D038856A...

Page 217: ...EDMT331529A Dimensions FXHQ MA 215 11 FXHQ100MAVE Unit mm 3D038857C...

Page 218: ...agrams EDMT331529A 216 FXHQ MA 3 Piping Diagrams FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE Refrigerant pipe connection port diameters C 4D034245L mm Model Gas Liquid FXHQ32MAVE 12 7 6 4 FXHQ63MAVE FXHQ100MAVE...

Page 219: ...1 C1R PRINTED CIRCUIT BOARD X13A P1 t P1 X25A X4A TO WIRELESS REMOTE CONTROLLER MAGNETIC RELAY M1S H4P T1R SELECTOR SWITCH MAIN SUB X18A T1R H2P R1T WIRELESS REMOTE CONTROLLER RECEIVER DISPLAY UNIT WI...

Page 220: ...Electric Characteristics EDMT331529A 218 FXHQ MA 5 Electric Characteristics FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE C 4D035304C...

Page 221: ...9 11 6 Safety Devices Setting C 3D034597L Model FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE Printed circuit board fuse 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protector C OFF 130 5 ON...

Page 222: ...e selected model of outdoor units outdoor air temperature and piping length Please confirm that the corrected capacity of the VRV system satisfies the required heat load 2 shows rated condition Model...

Page 223: ...B FXHQ32MAVE TC 0 707 0 692 0 745 0 768 0 788 0 819 0 844 SHF 1 098 1 181 1 127 1 102 1 082 1 055 1 042 FXHQ63MAVE TC 0 695 0 702 0 749 0 772 0 791 0 821 0 844 SHF 1 120 1 169 1 122 1 098 1 079 1 058...

Page 224: ...stributions Reference Data EDMT331529A 222 FXHQ MA 8 Air Velocity and Temperature Distributions Reference Data FXHQ100MAVE Heating Air velocity distribution Centre airflow FXHQ100MAVE Heating Temperat...

Page 225: ...EDMT331529A Sound Levels FXHQ MA 223 11 9 Sound Levels FXHQ32MAVE FXHQ63MAVE 4D035301 4D035302...

Page 226: ...Sound Levels EDMT331529A 224 FXHQ MA FXHQ100MAVE 4D035303A...

Page 227: ...it 4D040446C 10 2 Optional Accessories for Controls Refer to page 526 Item Model FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE Drain pump kit KDU50N60VE KDU50N125VE Replacement long life filter Resin net KAF501DA...

Page 228: ...Accessories EDMT331529A 226 FXHQ MA...

Page 229: ...3 4 Wiring Diagrams 234 5 Electric Characteristics 235 6 Safety Devices Setting 236 7 Capacity Tables 237 7 1 Cooling Capacity 237 7 2 Heating Capacity 237 7 3 Correction Factor for Te 9 C 238 8 Sound...

Page 230: ...ive Direct drive Direct drive Direct drive Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling...

Page 231: ...Direct drive Direct drive Direct drive Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling an...

Page 232: ...Dimensions EDMT331529A 230 FXAQ P 2 Dimensions FXAQ20PVE FXAQ25PVE FXAQ32PVE Unit mm 3D065064A...

Page 233: ...EDMT331529A Dimensions FXAQ P 231 12 FXAQ40PVE FXAQ50PVE Unit mm 3D065065A...

Page 234: ...Dimensions EDMT331529A 232 FXAQ P FXAQ63PVE Unit mm 3D065066A...

Page 235: ...33 12 3 Piping Diagrams FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE Refrigerant pipe connection port diameters mm Model Gas Liquid FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE 12...

Page 236: ...Wiring Diagrams EDMT331529A 234 FXAQ P 4 Wiring Diagrams FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE 3D076498...

Page 237: ...EDMT331529A Electric Characteristics FXAQ P 235 12 5 Electric Characteristics FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE 4D077066...

Page 238: ...Safety Devices Setting C 4D034906P Model FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE Printed circuit board fuse 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A 250V 3 15A Fan mo...

Page 239: ...he required heat load 2 shows rated condition Model Capacity indication Indoor air temp 14 0 CWB 16 0 CWB 18 0 CWB 19 0 CWB 20 0 CWB 22 0 CWB 24 0 CWB 20 CDB 23 CDB 26 CDB 27 CDB 28 CDB 30 CDB 32 CDB...

Page 240: ...0 836 SHF 1 122 1 195 1 143 1 115 1 092 1 061 1 046 FXAQ32PVE TC 0 701 0 688 0 736 0 760 0 781 0 815 0 836 SHF 1 106 1 194 1 141 1 113 1 091 1 059 1 049 FXAQ40PVE TC 0 678 0 685 0 748 0 772 0 793 0 8...

Page 241: ...EDMT331529A Sound Levels FXAQ P 239 12 8 Sound Levels FXAQ20PVE FXAQ25PVE 4D077090 4D077091...

Page 242: ...Sound Levels EDMT331529A 240 FXAQ P FXAQ32PVE FXAQ40PVE 4D077092 4D077093...

Page 243: ...EDMT331529A Sound Levels FXAQ P 241 12 FXAQ50PVE FXAQ63PVE 4D077094 4D077095...

Page 244: ...1529A 242 FXAQ P 9 Accessories 9 1 Optional Accessories for Unit 9 2 Optional Accessories for Controls Refer to page 526 Item Model FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE Drain pu...

Page 245: ...MA 251 3 Piping Diagrams 254 4 Wiring Diagrams 255 5 Electric Characteristics 256 6 Safety Devices Setting 257 7 Capacity Tables 258 7 1 Cooling Capacity 258 7 2 Heating Capacity 258 7 3 Correction Fa...

Page 246: ...drive Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Sound absorbing thermal...

Page 247: ...Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Sound absorbing thermal insula...

Page 248: ...drive Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Sound absorbing thermal...

Page 249: ...ct drive Temperature control Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating Sound absorbing therm...

Page 250: ...SORY 1750 OR MORE 156 65 42 10 2 209 219 70 575 219 172 10 590 149 192 4 181 102 194 600 596 222 3 4 12 30 SLOT HOLE 301 233 184 1 PERFORATED HOLE FOR PIPING 13 10 88 143 15 2 12 18 SLOT HOLE 5 165 15...

Page 251: ...BOTTOM 1 2 12 18 SLOT HOLE 15 184 192 15 736 165 730 219 42 575 194 PERFORATED HOLE FOR PIPING 172 4 12 30 SLOT HOLE 102 WIRING HOLE 219 233 149 10 222 181 5 301 143 70 2 391 209 88 13 156 10 65 600 1...

Page 252: ...LEVEL ADJUSTING SCREW AS STANDARD ACCESSORY 4 M6 15 192 42 4 2 12 18 SLOT HOLE 65 219 233 575 3 156 143 10 209 1420 301 1016 2 219 149 10 222 PERFORATED HOLE FOR PIPING 600 WIRING HOLE 88 13 1010 5 PE...

Page 253: ...CHARGE FLANGE DISCHARGE FLANGE 150 OR MORE 4 M6 REQUIRED INSTALLATION SPACE FRONT FACE LEVEL ADJUSTING SCREW AS STANDARD ACCESSORY HOLE FOR FIXING TO THE FLOOR NOTE 2 12 18 SLOT HOLE TOTAL ON RIGHT LE...

Page 254: ...S STANDARD ACCESSORY TOTAL ON RIGHT LEFT DISCHARGE FLANGE TOTAL ON FRONT REAR 730 389 609 199 130 35 42 65 11 218 7 2 4 7 HOLE 74 181 6 100 600 192 103 702 65 2 25 3 163 206 152 TOP PLATE 4 391 42 129...

Page 255: ...EDMT331529A Dimensions FXLQ MA FXNQ MA 253 13 FXNQ50MAVE FXNQ63MAVE Unit mm 3D038865C...

Page 256: ...XLQ50MAVE FXLQ63MAVE FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE Refrigerant pipe connection port diameters C 4D034245L mm Model Gas Liquid FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ4...

Page 257: ...1529A Wiring Diagrams FXLQ MA FXNQ MA 255 13 4 Wiring Diagrams FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE C 3D0...

Page 258: ...cteristics EDMT331529A 256 FXLQ MA FXNQ MA 5 Electric Characteristics FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAV...

Page 259: ...Q32MAVE FXLQ40MAVE FXNQ40MAVE FXLQ50MAVE FXNQ50MAVE FXLQ63MAVE FXNQ63MAVE Printed circuit board fuse 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A 250V 5A Fan motor thermal fuse C Fan motor thermal protecto...

Page 260: ...VE 25 1 9 1 6 2 3 1 8 2 6 2 0 2 8 2 1 2 8 2 0 2 9 1 9 3 0 1 8 FXLQ32MAVE 32 2 4 1 9 2 9 2 2 3 4 2 5 3 6 2 5 3 6 2 3 3 7 2 3 3 8 2 2 FXLQ40MAVE 40 3 0 2 5 3 6 2 7 4 2 3 1 4 5 3 1 4 6 3 1 4 7 3 0 4 8 2...

Page 261: ...0 842 0 865 SHF 1 194 1 160 1 107 1 088 1 073 1 046 1 029 FXLQ63MAVE TC 0 662 0 713 0 773 0 795 0 813 0 843 0 866 SHF 1 179 1 155 1 103 1 084 1 071 1 049 1 039 FXNQ20MAVE TC 0 650 0 709 0 767 0 788 0...

Page 262: ...Sound Levels EDMT331529A 260 FXLQ MA FXNQ MA 8 Sound Levels 8 1 FXLQ MA FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE 4D034528A 4D034564A...

Page 263: ...EDMT331529A Sound Levels FXLQ MA FXNQ MA 261 13 FXLQ40MAVE FXLQ50MAVE 4D034565A 4D034566A...

Page 264: ...Sound Levels EDMT331529A 262 FXLQ MA FXNQ MA FXLQ63MAVE 4D034567A...

Page 265: ...EDMT331529A Sound Levels FXLQ MA FXNQ MA 263 13 8 2 FXNQ MA FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE 4D034534B 4D034535A...

Page 266: ...Sound Levels EDMT331529A 264 FXLQ MA FXNQ MA FXNQ40MAVE FXNQ50MAVE 4D034536B 4D034537B...

Page 267: ...EDMT331529A Sound Levels FXLQ MA FXNQ MA 265 13 FXNQ63MAVE 4D034538B...

Page 268: ...AVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE C 4D034527C 500 570 710 Unit mm FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE FXLQ20MAVE FXLQ25MAVE...

Page 269: ...es for Unit C 4D034574B 10 2 Optional Accessories for Controls Refer to page 526 Item Model FXLQ20MAVE FXNQ20MAVE FXLQ25MAVE FXNQ25MAVE FXLQ32MAVE FXNQ32MAVE FXLQ40MAVE FXNQ40MAVE FXLQ50MAVE FXNQ50MAV...

Page 270: ...Accessories EDMT331529A 268 FXLQ MA FXNQ MA...

Page 271: ...or Te 9 C 279 8 Fan Characteristics 280 9 Fan Characteristics For Pulley Selection 283 9 1 Pulley Selection 283 9 2 Fan Motor Specifications 286 9 3 How to Select Motor Pulley 286 9 4 Pulley and Fan B...

Page 272: ...n Sirocco fan Sirocco fan Motor output Number of units W 750 1 1 500 1 1 500 1 Airflow rate m min 43 69 86 cfm 1 518 2 436 3 036 4 External static pressure Pa 152 217 281 Drive Belt drive Belt drive B...

Page 273: ...EDMT331529A Dimensions FXVQ N 271 14 2 Dimensions FXVQ125NY1 Unit mm 3D081764B...

Page 274: ...Dimensions EDMT331529A 272 FXVQ N FXVQ200NY1 Unit mm 3D081765B...

Page 275: ...EDMT331529A Dimensions FXVQ N 273 14 FXVQ250NY1 Unit mm 3D081766B...

Page 276: ...Diagrams EDMT331529A 274 FXVQ N 3 Piping Diagrams FXVQ125NY1 FXVQ200NY1 FXVQ250NY1 Refrigerant pipe connection port diameters mm Model Gas Liquid FXVQ125NY1 15 9 9 5 FXVQ200NY1 19 1 FXVQ250NY1 22 2 4D...

Page 277: ...EDMT331529A Wiring Diagrams FXVQ N 275 14 4 Wiring Diagrams FXVQ125NY1 FXVQ200NY1 FXVQ250NY1 3D093434...

Page 278: ...Electric Characteristics EDMT331529A 276 FXVQ N 5 Electric Characteristics FXVQ125NY1 FXVQ200NY1 FXVQ250NY1 4D095121C...

Page 279: ...9A Safety Devices Setting FXVQ N 277 14 6 Safety Devices Setting C 4D095114 Model FXVQ125NY1 FXVQ200NY1 FXVQ250NY1 Printed circuit board fuse 250V 5A 250V 5A 250V 5A Over current relay Fan motor 2 0A...

Page 280: ...its outdoor air temperature and piping length Please confirm that the corrected capacity of the VRV system satisfies the required heat load 2 shows rated condition C CA13A279A Model Capacity indicatio...

Page 281: ...B FXVQ125NY1 TC 0 685 0 719 0 782 0 801 0 816 0 842 0 865 SHF 1 133 1 150 1 099 1 081 1 070 1 055 1 056 FXVQ200NY1 TC 0 691 0 697 0 762 0 790 0 810 0 834 0 856 SHF 1 109 1 169 1 111 1 087 1 069 1 056...

Page 282: ...Fan Characteristics EDMT331529A 280 FXVQ N 8 Fan Characteristics FXVQ125NY1 4D095108...

Page 283: ...EDMT331529A Fan Characteristics FXVQ N 281 14 FXVQ200NY1 4D095109...

Page 284: ...Fan Characteristics EDMT331529A 282 FXVQ N FXVQ250NY1 4D095111...

Page 285: ...EDMT331529A Fan Characteristics For Pulley Selection FXVQ N 283 14 9 Fan Characteristics For Pulley Selection 9 1 Pulley Selection FXVQ125NY1 4D095089...

Page 286: ...Fan Characteristics For Pulley Selection EDMT331529A 284 FXVQ N FXVQ200NY1 4D095090...

Page 287: ...EDMT331529A Fan Characteristics For Pulley Selection FXVQ N 285 14 FXVQ250NY1 4D095091...

Page 288: ...t of V belt length Nominal number is usually shown in inch Distance between the shafts of the pulleys C Refer to each Fan Characteristics drawing for the latest value Items Rated motor output 0 75 1 5...

Page 289: ...125 200 250N Operating procedures Following the installation manual remove the front panel and others Parallelism criteria K Less than 10 arc minutes discrepancies of 3mm per 1m 3B 291 42 Boss inner d...

Page 290: ...After replacing belt or pulley conduct the test operation and check if there is no abnormal noise or vibration Refer to the JIS B 1854 Pulley and JIS K 6323 V belt for details JIS Japanese Industrial...

Page 291: ...58 1473 1473 87 2210 2210 140 3556 3556 30 762 762 59 1499 1499 88 2235 2235 142 31 787 787 60 1524 1524 89 2261 2261 145 3683 3683 32 813 813 61 1549 1549 90 2286 2286 148 33 838 838 62 1575 1575 91...

Page 292: ...Sound Levels EDMT331529A 290 FXVQ N 10 Sound Levels FXVQ125NY1 FXVQ200NY1 4D095080 4D095081...

Page 293: ...EDMT331529A Sound Levels FXVQ N 291 14 FXVQ250NY1 4D095082...

Page 294: ...Centre of Gravity EDMT331529A 292 FXVQ N 11 Centre of Gravity FXVQ125NY1 FXVQ200NY1 FXVQ250NY1 Unit mm 4D095078...

Page 295: ...61L140 KAFJ261L224 KAFJ261L280 Ultra long life filter Front suction filter chamber for high efficiency filter Front suction base flange KD 9A140 KD 9A200 KD 9A280 Suction grille KDGF 9A140 KDGF 9A200...

Page 296: ...Dimensions of Optional Accessories EDMT331529A 294 FXVQ N 13 Dimensions of Optional Accessories FXVQ125NY1 FXVQ200NY1 3D083638B Unit mm 3D083639B Unit mm...

Page 297: ...EDMT331529A Dimensions of Optional Accessories FXVQ N 295 14 FXVQ250NY1 3D083640B Unit mm...

Page 298: ...eliability may decrease For details please see the Airflow range section When the outdoor air processing mode is selected the machine controls the operation so that the temperature of the discharge ai...

Page 299: ...ngs as shown below after completing test run Please also see the installation manual of the indoor unit for the setting method Operation mode Mode No Setting switch No Setting position No Standard ope...

Page 300: ...l static pressure 4 Pa 120 150 110 Motor pulley A109 A127 A115 Gas pipe diameter Model name 15 9 19 1 22 2 125 Type 200 Type 250 Type Capacity characteristics outdoor air processing mode Cooling Heati...

Page 301: ...cs 324 7 Capacity Tables 325 7 1 Cooling Capacity 325 7 2 Heating Capacity 326 8 Fan Characteristics 327 8 1 Slim Ceiling Mounted Duct Type 327 9 Sound Levels 330 9 1 Indoor Units 330 10 Accessories 3...

Page 302: ...EDMT331529A 300 Residential Indoor Units with Connection to BP Units 11 1 CDXS FDXS 344 11 2 FTXJ 345 11 3 FTXS 346...

Page 303: ...Indoor unit BP unit Power supply Slim ceiling mounted duct type CDXS25EAVMA BPMKS967A3 BPMKS967A2 1 phase 220 240 220 230V 50 60Hz CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA Wall mounted...

Page 304: ...2 8 7 8 0 7 3 6 2 l s 145 133 122 103 145 133 122 103 cfm 307 282 258 219 307 282 258 219 Fan Type Sirocco fan Sirocco fan Motor output W 62 62 Speed Steps 5 Steps Quiet Auto 5 Steps Quiet Auto Air fi...

Page 305: ...31 31 Sound pressure level H M L SL dB A 35 33 31 29 35 33 31 29 External static pressure Pa 40 40 Heat insulation Both liquid and gas pipes Both liquid and gas pipes Piping connection Liquid mm 6 4 6...

Page 306: ...gas pipes Both liquid and gas pipes Piping connection Liquid mm 6 4 6 4 Gas mm 9 5 9 5 Drain mm 18 0 18 0 Drawing No C 3D092101 C 3D092104 Model FTXJ35NVMVW FTXJ35NVMVS Cooling Heating Cooling Heatin...

Page 307: ...uiet Auto Air direction control Right Left Horizontal Downwards Right Left Horizontal Downwards Air filter Removable Washable Mildew proof Removable Washable Mildew proof Temperature control Microcomp...

Page 308: ...ating Cooling Heating Front panel colour White White Airflow rate H M L SL m min 8 7 6 7 4 7 3 9 9 4 7 6 5 8 5 0 8 9 6 9 4 8 4 0 9 7 7 9 6 0 5 2 l s 145 112 78 65 157 127 97 83 148 115 80 67 162 132 1...

Page 309: ...mm 337 1 147 366 337 1 147 366 Weight kg 12 12 Gross weight kg 17 17 Sound pressure level H M L SL dB A 44 40 35 32 42 38 33 30 45 41 36 33 44 40 35 32 Heat insulation Both liquid and gas pipes Both...

Page 310: ...Dimensions EDMT331529A 308 Residential Indoor Units with Connection to BP Units 3 Dimensions 3 1 Indoor Units 3 1 1 Slim Ceiling Mounted Duct Type CDXS25EAVMA CDXS35EAVMA Unit mm 3D050379E...

Page 311: ...EDMT331529A Dimensions Residential Indoor Units with Connection to BP Units 309 15 FDXS25CVMA FDXS35CVMA FDXS50CVMA Unit mm 3D054289B...

Page 312: ...Dimensions EDMT331529A 310 Residential Indoor Units with Connection to BP Units FDXS60CVMA Unit mm 3D054290B...

Page 313: ...EDMT331529A Dimensions Residential Indoor Units with Connection to BP Units 311 15 3 1 2 Wall Mounted Type FTXJ25NVMVW FTXJ25NVMVS FTXJ35NVMVW FTXJ35NVMVS Unit mm 3D095610...

Page 314: ...Dimensions EDMT331529A 312 Residential Indoor Units with Connection to BP Units FTXJ50NVMVW FTXJ50NVMVS 3D095611 Unit mm...

Page 315: ...EDMT331529A Dimensions Residential Indoor Units with Connection to BP Units 313 15 FTXS20DVMA FTXS25EVMA FTXS35EVMA Unit mm 3D047956H...

Page 316: ...Dimensions EDMT331529A 314 Residential Indoor Units with Connection to BP Units FTXS50FVMA FTXS60FVMA Unit mm 3D054935E...

Page 317: ...EDMT331529A Dimensions Residential Indoor Units with Connection to BP Units 315 15 FTXS71FVMA Unit mm 3D054936E...

Page 318: ...DMT331529A 316 Residential Indoor Units with Connection to BP Units 4 Piping Diagrams 4 1 Indoor Units 4 1 1 Slim Ceiling Mounted Duct Type CDXS25EAVMA CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDX...

Page 319: ...DMT331529A Piping Diagrams Residential Indoor Units with Connection to BP Units 317 15 4 1 2 Wall Mounted Type FTXJ25NVMVW FTXJ25NVMVS FTXJ35NVMVW FTXJ35NVMVS 4D091640 FTXJ50NVMVW FTXJ50NVMVS 4D091641...

Page 320: ...Piping Diagrams EDMT331529A 318 Residential Indoor Units with Connection to BP Units FTXS20DVMA FTXS25EVMA FTXS35EVMA FTXS50FVMA FTXS60FVMA 4D047912S 4D040081Y...

Page 321: ...EDMT331529A Piping Diagrams Residential Indoor Units with Connection to BP Units 319 15 FTXS71FVMA 4D040082W...

Page 322: ...MT331529A 320 Residential Indoor Units with Connection to BP Units 5 Wiring Diagrams 5 1 Indoor Units 5 1 1 Slim Ceiling Mounted Duct Type CDXS25EAVMA CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS...

Page 323: ...EDMT331529A Wiring Diagrams Residential Indoor Units with Connection to BP Units 321 15 5 1 2 Wall Mounted Type FTXJ25NVMVW FTXJ25NVMVS FTXJ35NVMVW FTXJ35NVMVS FTXJ50NVMVW FTXJ50NVMVS...

Page 324: ...Wiring Diagrams EDMT331529A 322 Residential Indoor Units with Connection to BP Units FTXS20DVMA FTXS25EVMA FTXS35EVMA C 3D046453H...

Page 325: ...EDMT331529A Wiring Diagrams Residential Indoor Units with Connection to BP Units 323 15 FTXS50FVMA FTXS60FVMA FTXS71FVMA C 3D038530U...

Page 326: ...0 8 15 0 062 0 6 100 100 FDXS35CVMA 0 8 15 0 062 0 6 100 100 FDXS50CVMA 0 9 15 0 130 0 7 140 140 FDXS60CVMA 1 0 15 0 130 0 8 160 160 FTXJ25NVMVW 50Hz 220 240V Max 264V Min 198V 0 2 15 0 029 0 15 22 33...

Page 327: ...5 2 7 3 8 2 8 4 0 2 6 4 3 2 7 FDXS25CVMA 25 9 5 1 5 1 4 1 8 1 7 2 3 1 9 2 5 2 0 2 7 2 1 2 9 1 9 3 1 1 9 FDXS35CVMA 35 10 0 2 0 2 0 2 5 2 4 3 2 2 7 3 5 2 8 3 8 2 9 4 0 2 6 4 3 2 7 FDXS50CVMA 50 12 0 2...

Page 328: ...l difference 0 m 3 shows rated condition Model Capacity indication Indoorairtemp CDB 16 0 18 0 20 0 21 0 22 0 24 0 kW kW kW kW kW kW CDXS25EAVMA 25 3 3 3 3 3 2 3 1 2 9 2 7 CDXS35EAVMA 35 4 6 4 6 4 4 4...

Page 329: ...331529A Fan Characteristics Residential Indoor Units with Connection to BP Units 327 15 8 Fan Characteristics 8 1 Slim Ceiling Mounted Duct Type CDXS25EAVMA CDXS35EAVMA FDXS25CVMA C 3D051853D C 3D0457...

Page 330: ...Fan Characteristics EDMT331529A 328 Residential Indoor Units with Connection to BP Units FDXS35CVMA FDXS50CVMA C 3D045761G C 3D045762H...

Page 331: ...EDMT331529A Fan Characteristics Residential Indoor Units with Connection to BP Units 329 15 FDXS60CVMA C 3D045763G...

Page 332: ...Sound Levels EDMT331529A 330 Residential Indoor Units with Connection to BP Units 9 Sound Levels 9 1 Indoor Units 9 1 1 Slim Ceiling Mounted Duct Type CDXS25EAVMA CDXS35EAVMA 3D051866C...

Page 333: ...EDMT331529A Sound Levels Residential Indoor Units with Connection to BP Units 331 15 FDXS25CVMA 3D046243E...

Page 334: ...Sound Levels EDMT331529A 332 Residential Indoor Units with Connection to BP Units FDXS35CVMA 3D046244E...

Page 335: ...EDMT331529A Sound Levels Residential Indoor Units with Connection to BP Units 333 15 FDXS50CVMA 3D046245G...

Page 336: ...Sound Levels EDMT331529A 334 Residential Indoor Units with Connection to BP Units FDXS60CVMA 3D046246F...

Page 337: ...EDMT331529A Sound Levels Residential Indoor Units with Connection to BP Units 335 15 9 1 2 Wall Mounted Type FTXJ25NVMVW FTXJ25NVMVS 3D090551B...

Page 338: ...Sound Levels EDMT331529A 336 Residential Indoor Units with Connection to BP Units FTXJ35NVMVW FTXJ35NVMVS 3D090552B...

Page 339: ...EDMT331529A Sound Levels Residential Indoor Units with Connection to BP Units 337 15 FTXJ50NVMVW FTXJ50NVMVS 3D090553B...

Page 340: ...Sound Levels EDMT331529A 338 Residential Indoor Units with Connection to BP Units FTXS20DVMA FTXS25EVMA 3D048277E...

Page 341: ...EDMT331529A Sound Levels Residential Indoor Units with Connection to BP Units 339 15 FTXS35EVMA 3D048278E...

Page 342: ...Sound Levels EDMT331529A 340 Residential Indoor Units with Connection to BP Units FTXS50FVMA 3D054979F...

Page 343: ...EDMT331529A Sound Levels Residential Indoor Units with Connection to BP Units 341 15 FTXS60FVMA 3D040300L...

Page 344: ...Sound Levels EDMT331529A 342 Residential Indoor Units with Connection to BP Units FTXS71FVMA 3D040301J...

Page 345: ...be replaced approximately 3 years 10 2 Optional Accessories for Controls Refer to page 526 No Option name CDXS25EAVMA CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA 1 Insulation kit for high...

Page 346: ...f Gravity EDMT331529A 344 Residential Indoor Units with Connection to BP Units 11 Centre of Gravity 11 1 CDXS FDXS CDXS25EAVMA CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA 4D049301H Unit mm 4D046081M...

Page 347: ...9A Centre of Gravity Residential Indoor Units with Connection to BP Units 345 15 FDXS60CVMA 11 2 FTXJ FTXJ25NVMVW FTXJ25NVMVS FTXJ35NVMVW FTXJ35NVMVS FTXJ50NVMVW FTXJ50NVMVS Unit mm 4D090742B 4D046082...

Page 348: ...Centre of Gravity EDMT331529A 346 Residential Indoor Units with Connection to BP Units 11 3 FTXS FTXS20DVMA FTXS25EVMA FTXS35EVMA FTXS50FVMA FTXS60FVMA FTXS71FVMA 4D048210Y Unit mm 4D065095 Unit mm...

Page 349: ...nits 348 2 Dimensions 349 2 1 BP Units 349 3 Piping Diagrams 351 3 1 BP Units 351 4 Wiring Diagrams 352 4 1 BP Units 352 5 Electric Characteristics 353 6 Accessories 353 6 1 Optional Accessories 353 7...

Page 350: ...e weight kg 8 7 5 Gross weight kg 12 11 Number of wiring connections 3 for power supply including earth wiring 2 for interunit wiring outdoor unit BP BP BP 4 for interunit wiring BP indoor unit Piping...

Page 351: ...ing of 650mm square for service and maintenance 125 For outdoor unit side Liquid O D 9 5 For outdoor side Gas 100 I D 19 1 Dimple I D 6 4 165 90 For indoor side Liquid Cut line for O D 6 4 45 65 110 I...

Page 352: ...4 165 90 For indoor side Liquid Cut line for O D 6 4 servicing space Min390 45 65 110 I D 9 5 Cut line for I D 15 9 150 O D 19 1 110 304 The opening for Inspection Servicing is needed opening of 650mm...

Page 353: ...INDOOR UNIT 15 9CuT 15 9CuT 15 9CuT 6 4CuT 6 4CuT 6 4CuT ROOM B ROOM C ROOM A ROOM A ROOM B ROOM C GAS LIQUID LOCAL PIPING LOCAL PIPING LOCAL PIPING LOCAL PIPING LOCAL PIPING LOCAL PIPING LOCAL PIPING...

Page 354: ...Wiring Diagrams EDMT331529A 352 BP Units 4 Wiring Diagrams 4 1 BP Units BPMKS967A3 BPMKS967A2 3D048288 3D048438...

Page 355: ...andard fuse rating Min 15A 4 Select wire size based on the MCA 5 Instead of fuse use circuit breaker 6 Regarding the power supply refer to the power supply of BP units Power supply intake is from BP u...

Page 356: ...Centre of Gravity EDMT331529A 354 BP Units 7 Centre of Gravity BPMKS967A3 BPMKS967A2 3D048409A Unit mm 3D048410A Unit mm...

Page 357: ...ation with little or no vibration That the refrigerant pipes for the indoor and outdoor units can be repaired with ease and that the units are placed well within the distance from each other allowed b...

Page 358: ...space Min 390 Servicing space Min 390 Servicing space Min 300 Installation restrictions Installation and service space Standard accessories 25 113 Wall mounted I D 9 5 O D 15 9 163 68 Cut line for I...

Page 359: ...or unit side Liquid For outdoor unit side Gas For indoor unit side Liquid Servicing is needed opening of 650mm square for service and maintenance The opening for Inspection 45 57 57 95 95 304 2 3 Braz...

Page 360: ...m the following Caution Before doing any wiring on site replace the electric box 1 Remove the screws and pull off the electrical equipment cover 2 Remove 4 screws shown in the figure on the below remo...

Page 361: ...tions in total 2 Create a gap with the wall and screw in the temporary screws and hang the BP unit 3 After checking with a level that the unit is level fix the unit with screws M5 field supply The til...

Page 362: ...erformance 2 Insulation of pipes 1 Attach heat insulation to each pipe 2 When attaching insulation to the pipes use one sided adhesive tape or similar materials to thoroughly prevent air from entering...

Page 363: ...any gaps from forming between the two and wrap with masking tape as shown in the figure Clasp field supply Clasp field supply Room B Gas Room C Gas Room C Liquid Room A Gas Room A Liquid Room B Liquid...

Page 364: ...Installation EDMT331529A 362 BP Units C 3P155399 1E...

Page 365: ...2 1 3 2 1 3 Room A Room B Room C Ground Fix each wire separately Safety breaker 15A Earth leakage circuit breaker Power supply 1 50Hz 220 240V 1 60Hz 220 230V Do not use tapped wires stand wires exten...

Page 366: ...ical equipment cover Malfunction code Nonconformity during installation Remedial action A9 Electric expansion valve connector not connected BP unit Please contact your dealer E2 Printed circuit board...

Page 367: ...Field Wiring 387 7 Electric Characteristics 390 8 Safety Devices Setting 391 9 Capacity Tables 392 9 1 Cooling Capacity for VRV Indoor Units Only Te 6 C 392 9 2 Cooling Capacity for Mixed Combination...

Page 368: ...Casing Color Ivory White Dimensions H W D mm 990 940 320 Heat Exchanger Cross Fin Coil Compressor Type Hermetically Sealed Swing Type Motor Output kW 1 92 Starting Method Soft Start Fan Type Propeller...

Page 369: ...Output kW 3 0 3 5 Starting Method Soft Start Soft Start Fan Type Propeller Fan Propeller Fan Motor Output W 200 70 2 Airflow Rate m min 76 106 Drive Direct Drive Direct Drive Connecting Pipes Liquid...

Page 370: ...Output kW 3 8 4 8 Starting Method Soft Start Soft Start Fan Type Propeller Fan Propeller Fan Motor Output W 200 2 200 2 Airflow Rate m min 140 140 Drive Direct Drive Direct Drive Connecting Pipes Liq...

Page 371: ...EDMT331529A Dimensions RXYMQ A 369 17 2 Dimensions RXYMQ4AVE Unit mm 3D075986H...

Page 372: ...Dimensions EDMT331529A 370 RXYMQ A RXYMQ5AVE Unit mm 3D091415A...

Page 373: ...EDMT331529A Dimensions RXYMQ A 371 17 RXYMQ6AVE Unit mm 3D091424A...

Page 374: ...Dimensions EDMT331529A 372 RXYMQ A RXYMQ8AY1 RXYMQ9AY1 Unit mm 3D084696D...

Page 375: ...EDMT331529A Service Space RXYMQ A 373 17 3 Service Space RXYMQ4AVE RXYMQ5AVE 3D091427A...

Page 376: ...Service Space EDMT331529A 374 RXYMQ A 3D091427A...

Page 377: ...EDMT331529A Service Space RXYMQ A 375 17 RXYMQ6AVE 3D091429A...

Page 378: ...Service Space EDMT331529A 376 RXYMQ A 3D091429A...

Page 379: ...EDMT331529A Service Space RXYMQ A 377 17 RXYMQ8AY1 RXYMQ9AY1 3D086314C...

Page 380: ...Service Space EDMT331529A 378 RXYMQ A 3D086314C...

Page 381: ...EDMT331529A Piping Diagrams RXYMQ A 379 17 4 Piping Diagrams RXYMQ4AVE 3D090890A...

Page 382: ...Piping Diagrams EDMT331529A 380 RXYMQ A RXYMQ5AVE 3D090815...

Page 383: ...EDMT331529A Piping Diagrams RXYMQ A 381 17 RXYMQ6AVE 3D091109...

Page 384: ...Piping Diagrams EDMT331529A 382 RXYMQ A RXYMQ8AY1 RXYMQ9AY1 3D084504B...

Page 385: ...EDMT331529A Wiring Diagrams RXYMQ A 383 17 5 Wiring Diagrams RXYMQ4AVE 3D089410...

Page 386: ...Wiring Diagrams EDMT331529A 384 RXYMQ A RXYMQ5AVE 3D089115A...

Page 387: ...EDMT331529A Wiring Diagrams RXYMQ A 385 17 RXYMQ6AVE 3D089116B...

Page 388: ...Wiring Diagrams EDMT331529A 386 RXYMQ A RXYMQ8AY1 RXYMQ9AY1 3D090907A...

Page 389: ...EDMT331529A Field Wiring RXYMQ A 387 17 6 Field Wiring RXYMQ4AVE RXYMQ5AVE 3D091881A...

Page 390: ...Field Wiring EDMT331529A 388 RXYMQ A RXYMQ6AVE 3D092117A...

Page 391: ...EDMT331529A Field Wiring RXYMQ A 389 17 RXYMQ8AY1 RXYMQ9AY1 3D086171C...

Page 392: ...Electric Characteristics EDMT331529A 390 RXYMQ A 7 Electric Characteristics RXYMQ4AVE RXYMQ5AVE RXYMQ6AVE RXYMQ8AY1 RXYMQ9AY1 3D092041...

Page 393: ...MQ8AY1 RXYMQ9AY1 Printed circuit board fuse A1P 250V 6 3A 250V 3 15A 250V 6 3A 250V 5A 250V 3 15A A2P 250V 6 3A A3P 250V 6 3A A4P DC650V 5A A5P DC650V 5A High pressure switch SPH OFF 4 0 MPa ON 3 0 0...

Page 394: ...5 2 25 14 0 4 54 0 54 5 41 0 63 6 28 0 73 6 72 0 79 7 16 0 84 8 03 0 95 8 90 1 07 16 0 8 31 1 16 9 92 1 42 11 5 1 68 12 3 1 82 13 1 1 96 14 7 2 28 15 3 2 37 16 0 4 54 0 55 5 41 0 64 6 28 0 75 6 72 0 8...

Page 395: ...85 0 95 8 40 1 02 8 95 1 09 10 0 1 24 11 1 1 39 16 0 10 4 1 59 12 4 1 93 14 4 2 30 15 4 2 48 16 4 2 67 18 4 3 11 19 0 3 20 16 0 5 67 0 71 6 76 0 84 7 85 0 97 8 40 1 04 8 95 1 11 10 0 1 26 11 1 1 41 18...

Page 396: ...1 05 9 60 1 12 10 2 1 20 11 5 1 36 12 7 1 52 16 0 11 9 1 67 14 2 2 04 16 5 2 42 17 6 2 62 18 7 2 82 20 8 3 21 21 2 3 23 16 0 6 48 0 78 7 73 0 92 8 98 1 07 9 60 1 14 10 2 1 22 11 5 1 38 12 7 1 55 18 0...

Page 397: ...6 1 72 13 4 1 84 14 3 1 97 16 1 2 23 17 8 2 50 16 0 16 6 2 40 19 8 2 92 23 0 3 47 24 6 3 76 26 2 4 04 29 4 4 70 30 2 4 77 16 0 9 07 1 28 10 8 1 50 12 6 1 75 13 4 1 87 14 3 2 00 16 1 2 27 17 8 2 54 18...

Page 398: ...1 89 14 4 2 03 15 3 2 16 17 2 2 45 19 1 2 75 16 0 17 8 2 78 21 3 3 39 24 7 4 02 26 4 4 35 28 1 4 68 30 3 5 05 30 9 5 09 16 0 9 72 1 41 11 6 1 66 13 5 1 92 14 4 2 06 15 3 2 20 17 2 2 50 19 1 2 80 18 0...

Page 399: ...13 1 2 89 13 8 3 02 14 2 3 05 31 0 6 88 1 23 8 58 1 65 10 9 2 32 12 0 2 69 13 1 3 09 13 6 3 14 14 0 3 17 33 0 6 88 1 31 8 58 1 76 10 9 2 47 12 0 2 87 12 9 3 22 13 4 3 26 13 8 3 29 35 0 6 88 1 39 8 58...

Page 400: ...0 3 04 31 0 6 53 1 15 8 15 1 54 10 3 2 15 11 4 2 49 12 5 2 85 13 4 3 13 13 8 3 16 33 0 6 53 1 22 8 15 1 64 10 3 2 29 11 4 2 66 12 5 3 05 13 2 3 24 13 6 3 28 35 0 6 53 1 30 8 15 1 74 10 3 2 44 11 4 2...

Page 401: ...3 9 3 03 31 0 6 19 1 08 7 72 1 43 9 78 1 99 10 8 2 30 11 8 2 63 13 3 3 12 13 6 3 14 33 0 6 19 1 14 7 72 1 52 9 78 2 12 10 8 2 45 11 8 2 80 13 1 3 23 13 4 3 26 35 0 6 19 1 21 7 72 1 62 9 78 2 26 10 8 2...

Page 402: ...7 3 01 31 0 5 85 1 00 7 29 1 32 9 24 1 83 10 2 2 11 11 2 2 41 13 1 3 07 13 5 3 13 33 0 5 85 1 07 7 29 1 41 9 24 1 95 10 2 2 25 11 2 2 57 12 9 3 22 13 3 3 25 35 0 5 85 1 13 7 29 1 50 9 24 2 08 10 2 2...

Page 403: ...1 63 10 7 2 18 13 6 3 07 15 0 3 56 16 3 4 05 16 8 4 10 17 4 4 14 33 0 8 60 1 73 10 7 2 32 13 6 3 27 15 0 3 80 16 1 4 20 16 6 4 25 17 1 4 30 35 0 8 60 1 83 10 7 2 47 13 6 3 49 15 0 4 05 15 8 4 36 16 3...

Page 404: ...4 3 97 31 0 8 17 1 52 10 2 2 03 12 9 2 84 14 2 3 29 15 6 3 78 16 7 4 08 17 1 4 12 33 0 8 17 1 62 10 2 2 16 12 9 3 03 14 2 3 51 15 6 4 03 16 4 4 24 16 9 4 28 35 0 8 17 1 72 10 2 2 30 12 9 3 23 14 2 3 7...

Page 405: ...2 3 95 31 0 7 74 1 42 9 65 1 89 12 2 2 63 13 5 3 04 14 8 3 48 16 5 4 07 16 9 4 11 33 0 7 74 1 51 9 65 2 01 12 2 2 80 13 5 3 24 14 8 3 71 16 2 4 22 16 7 4 26 35 0 7 74 1 60 9 65 2 14 12 2 2 98 13 5 3...

Page 406: ...0 3 93 31 0 7 31 1 33 9 11 1 75 11 5 2 42 12 7 2 79 13 9 3 19 16 3 4 05 16 7 4 09 33 0 7 31 1 41 9 11 1 86 11 5 2 58 12 7 2 98 13 9 3 40 16 1 4 20 16 5 4 24 35 0 7 31 1 49 9 11 1 98 11 5 2 75 12 7 3 1...

Page 407: ...3 1 68 12 3 2 26 15 5 3 17 17 1 3 68 18 3 4 03 18 8 4 07 19 4 4 12 33 0 9 83 1 79 12 3 2 40 15 5 3 38 17 1 3 93 18 0 4 18 18 6 4 23 19 1 4 27 35 0 9 83 1 90 12 3 2 56 15 5 3 61 17 1 4 19 17 7 4 33 18...

Page 408: ...5 3 94 31 0 9 33 1 58 11 6 2 10 14 7 2 94 16 3 3 41 17 8 3 91 18 6 4 06 19 2 4 10 33 0 9 33 1 67 11 6 2 24 14 7 3 14 16 3 3 63 17 8 4 16 18 4 4 21 18 9 4 25 35 0 9 33 1 78 11 6 2 38 14 7 3 34 16 3 3...

Page 409: ...9 2 3 93 31 0 8 84 1 47 11 0 1 96 14 0 2 72 15 4 3 14 16 9 3 60 18 4 4 04 19 0 4 08 33 0 8 84 1 56 11 0 2 08 14 0 2 90 15 4 3 35 16 9 3 84 18 2 4 19 18 7 4 24 35 0 8 84 1 66 11 0 2 21 14 0 3 09 15 4 3...

Page 410: ...0 3 91 31 0 8 35 1 37 10 4 1 81 13 2 2 51 14 6 2 89 15 9 3 30 18 2 4 03 18 7 4 06 33 0 8 35 1 46 10 4 1 93 13 2 2 67 14 6 3 08 15 9 3 52 17 9 4 18 18 4 4 22 35 0 8 35 1 55 10 4 2 05 13 2 2 84 14 6 3...

Page 411: ...8 2 41 17 2 3 24 21 7 4 55 24 0 5 28 25 9 5 94 26 8 6 00 27 6 6 06 33 0 13 8 2 56 17 2 3 45 21 7 4 86 24 0 5 64 25 5 6 16 26 4 6 23 27 2 6 29 35 0 13 8 2 72 17 2 3 67 21 7 5 18 24 0 6 02 25 1 6 38 26...

Page 412: ...7 5 81 31 0 13 1 2 26 16 3 3 02 20 6 4 22 22 8 4 89 24 9 5 60 26 5 5 98 27 2 6 04 33 0 13 1 2 40 16 3 3 21 20 6 4 50 22 8 5 21 24 9 5 98 26 1 6 20 26 8 6 27 35 0 13 1 2 55 16 3 3 42 20 6 4 80 22 8 5...

Page 413: ...7 3 5 79 31 0 12 4 2 11 15 4 2 81 19 6 3 90 21 6 4 51 23 6 5 16 26 2 5 96 26 9 6 01 33 0 12 4 2 24 15 4 2 98 19 6 4 16 21 6 4 81 23 6 5 51 25 8 6 18 26 5 6 24 35 0 12 4 2 38 15 4 3 17 19 6 4 43 21 6 5...

Page 414: ...0 5 76 31 0 11 7 1 97 14 6 2 60 18 5 3 59 20 4 4 14 22 3 4 73 25 9 5 93 26 6 5 99 33 0 11 7 2 09 14 6 2 76 18 5 3 83 20 4 4 42 22 3 5 05 25 5 6 16 26 2 6 21 35 0 11 7 2 22 14 6 2 94 18 5 4 08 20 4 4...

Page 415: ...2 79 18 4 3 75 23 3 5 27 25 7 6 12 26 6 6 33 27 5 6 41 28 3 6 48 33 0 14 7 2 97 18 4 3 99 23 3 5 62 25 7 6 53 26 2 6 57 27 1 6 65 27 9 6 73 35 0 14 7 3 15 18 4 4 25 23 3 6 00 25 3 6 77 25 7 6 81 26 6...

Page 416: ...6 21 31 0 14 0 2 62 17 5 3 50 22 1 4 89 24 4 5 66 26 3 6 31 27 2 6 38 28 0 6 45 33 0 14 0 2 78 17 5 3 72 22 1 5 21 24 4 6 04 25 9 6 55 26 7 6 62 27 6 6 70 35 0 14 0 2 95 17 5 3 96 22 1 5 55 24 4 6 44...

Page 417: ...0 6 18 31 0 13 3 2 45 16 5 3 25 21 0 4 52 23 1 5 22 25 3 5 98 26 8 6 36 27 6 6 42 33 0 13 3 2 60 16 5 3 46 21 0 4 82 23 1 5 57 25 3 6 38 26 4 6 60 27 2 6 67 35 0 13 3 2 76 16 5 3 67 21 0 5 13 23 1 5 9...

Page 418: ...6 15 31 0 12 5 2 28 15 6 3 01 19 8 4 16 21 8 4 80 23 9 5 48 26 5 6 33 27 3 6 39 33 0 12 5 2 42 15 6 3 20 19 8 4 43 21 8 5 12 23 9 5 85 26 1 6 57 26 9 6 64 35 0 12 5 2 57 15 6 3 40 19 8 4 72 21 8 5 45...

Page 419: ...4 7 15 0 8 19 2 64 7 98 2 59 7 50 2 41 7 26 2 32 7 02 2 23 6 54 2 05 12 6 13 0 8 82 2 00 8 80 2 08 8 77 2 17 8 76 2 21 8 75 2 26 8 73 2 34 12 6 13 0 8 46 2 61 7 98 2 43 7 50 2 26 7 26 2 18 7 02 2 10 6...

Page 420: ...48 3 25 8 94 3 03 8 40 2 81 8 13 2 71 7 86 2 60 7 32 2 40 12 6 13 0 10 4 2 61 10 4 2 72 10 4 2 82 10 4 2 87 10 3 2 92 10 3 3 02 12 6 13 0 9 48 3 05 8 94 2 85 8 40 2 65 8 13 2 55 7 86 2 45 7 32 2 26 10...

Page 421: ...1 8 4 14 11 5 4 06 10 8 3 77 10 5 3 63 10 1 3 49 9 41 3 21 12 6 13 0 12 7 3 13 12 7 3 26 12 6 3 40 12 6 3 47 12 6 3 53 12 6 3 67 12 6 13 0 12 2 4 09 11 5 3 81 10 8 3 54 10 5 3 41 10 1 3 28 9 41 3 03 1...

Page 422: ...5 6 45 16 0 6 23 15 0 5 79 14 5 5 57 14 0 5 35 13 1 4 93 12 6 13 0 17 8 4 90 17 8 5 10 17 7 5 31 17 7 5 42 17 7 5 52 17 6 5 73 12 6 13 0 16 9 6 28 16 0 5 85 15 0 5 44 14 5 5 24 14 0 5 04 13 1 4 65 10...

Page 423: ...6 6 6 62 16 5 6 75 15 6 6 31 15 1 6 08 14 6 5 84 13 6 5 38 12 6 13 0 17 8 4 93 17 8 5 16 17 7 5 38 17 7 5 50 17 7 5 61 17 6 5 84 12 6 13 0 17 4 6 75 16 6 6 39 15 6 5 94 15 1 5 72 14 6 5 50 13 6 5 07 1...

Page 424: ...Capacity Tables EDMT331529A 422 RXYMQ A 9 4 Capacity Correction Factor RXYMQ4AVE 3D092042A...

Page 425: ...EDMT331529A Capacity Tables RXYMQ A 423 17 RXYMQ5AVE 3D092043A...

Page 426: ...Capacity Tables EDMT331529A 424 RXYMQ A RXYMQ6AVE 3D092044A...

Page 427: ...EDMT331529A Capacity Tables RXYMQ A 425 17 RXYMQ8AY1 RXYMQ9AY1 3D086420B...

Page 428: ...g integrated heating capacity Note It will be seen from the figure above that the integrated heating capacity expresses the integrated heating capacity for a single cycle from defrosting operation to...

Page 429: ...EDMT331529A Operation Limits RXYMQ A 427 17 10 Operation Limits RXYMQ4AVE RXYMQ5AVE RXYMQ6AVE RXYMQ8AY1 RXYMQ9AY1 3D045713F...

Page 430: ...Sound Levels EDMT331529A 428 RXYMQ A 11 Sound Levels RXYMQ4AVE Cooling RXYMQ4AVE Heating 4D091258A 4D091259...

Page 431: ...EDMT331529A Sound Levels RXYMQ A 429 17 RXYMQ5AVE Cooling RXYMQ5AVE Heating 4D091260A 4D091261...

Page 432: ...Sound Levels EDMT331529A 430 RXYMQ A RXYMQ6AVE Cooling RXYMQ6AVE Heating 4D091262A 4D091278...

Page 433: ...EDMT331529A Sound Levels RXYMQ A 431 17 RXYMQ8AY1 Cooling RXYMQ8AY1 Heating 4D086122B 4D086168A...

Page 434: ...Sound Levels EDMT331529A 432 RXYMQ A RXYMQ9AY1 Cooling RXYMQ9AY1 Heating 4D086123B 4D086166A...

Page 435: ...RXYMQ8AY1 RXYMQ9AY1 Cool Heat Selector KRC19 26A Fixing box KJB111A REFNET header KHRP26M22H Max 4 branch KHRP26M33H Max 8 branch REFNET joint KHRP26A22T KHRP26A22T KHRP26A33T Central drain plug KKPJ5...

Page 436: ...Accessories EDMT331529A 434 RXYMQ A...

Page 437: ...Q4AVE 438 2 2 RXYMQ5AVE 454 2 3 RXYMQ6AVE 470 2 4 RXYMQ8AY1 RXYMQ9AY1 486 3 REFNET Pipe System 502 3 1 Layout Example 502 3 2 REFNET Joints and Headers 504 4 REFNET Joint and Header 506 4 1 REFNET Joi...

Page 438: ...Centre of Gravity EDMT331529A 436 Installation of Outdoor Units 1 Centre of Gravity RXYMQ4AVE RXYMQ5AVE Unit mm 4D091860B RXYMQ6AVE Unit mm 4D091861A...

Page 439: ...EDMT331529A Centre of Gravity Installation of Outdoor Units 437 18 RXYMQ8AY1 RXYMQ9AY1 Unit mm 4D086172C...

Page 440: ...U LQGRRU XQLWV WKH DLU FRQGLWLRQLQJ V VWHP ZLOO QRW RSHUDWH QRUPDOO 3RZHU YROWDJH RI WKLV VHULHV SURGXFW LV VLQJOH SKDVH a 9 9 a 9 9 5HIULJHUDQW SLSLQJ FRQQHFWLRQ 5HIULJHUDQW SLSLQJ FRQQHFWLRQ 3OHDVH...

Page 441: ...d accessories and parts for installation Failure to use the specified parts may result in water leakage electric shocks fire hazards or the unit failing to operate normally Note RU KRZ WR LQVWDOO WKH...

Page 442: ...Installation Manual EDMT331529A 440 Installation of Outdoor Units 1P388325 1...

Page 443: ...EDMT331529A Installation Manual Installation of Outdoor Units 441 18 1P388325 1...

Page 444: ...Installation Manual EDMT331529A 442 Installation of Outdoor Units 1P388325 1...

Page 445: ...EDMT331529A Installation Manual Installation of Outdoor Units 443 18 1P388325 1...

Page 446: ...Installation Manual EDMT331529A 444 Installation of Outdoor Units 1P388325 1...

Page 447: ...EDMT331529A Installation Manual Installation of Outdoor Units 445 18 1P388325 1...

Page 448: ...Installation Manual EDMT331529A 446 Installation of Outdoor Units 1P388318 1...

Page 449: ...EDMT331529A Installation Manual Installation of Outdoor Units 447 18 C 1P388318 1...

Page 450: ...Installation Manual EDMT331529A 448 Installation of Outdoor Units...

Page 451: ...EDMT331529A Installation Manual Installation of Outdoor Units 449 18 C 1P388318 1...

Page 452: ...WKH 6HUYLFH 3UHFDXWLRQV ODEHO DWWDFKHG XQGHU WKH IURQW SDQHO RI WKH HOHFWURQLF FRPSRQHQW ER Procedure QVWDOO WKH IURQW SDQHO ZHOO DQG WXUQ RQ WKH SRZHU VXSSO RI DOO LQGRRU DQG RXWGRRU XQLWV RI WKH V V...

Page 453: ...EDMT331529A Installation Manual Installation of Outdoor Units 451 18 1P388318 1...

Page 454: ...Installation Manual EDMT331529A 452 Installation of Outdoor Units 1P388318 1...

Page 455: ...EDMT331529A Installation Manual Installation of Outdoor Units 453 18 2P388309 1...

Page 456: ...units the air conditioning system will not operate normally 5 Power voltage of this series product is single phase 230 240V 50Hz AV4A 220 230 220V 50 60Hz AVE Refrigerant piping connection Refrigerant...

Page 457: ...ed accessories and parts for installation Failure to use the specified parts may result in water leakage electric shocks fire hazards or the unit failing to operate normally Note RU KRZ WR LQVWDOO WKH...

Page 458: ...Installation Manual EDMT331529A 456 Installation of Outdoor Units 1P388323 1...

Page 459: ...EDMT331529A Installation Manual Installation of Outdoor Units 457 18 1P388323 1...

Page 460: ...Installation Manual EDMT331529A 458 Installation of Outdoor Units 1P388323 1...

Page 461: ...EDMT331529A Installation Manual Installation of Outdoor Units 459 18 1P388323 1...

Page 462: ...Installation Manual EDMT331529A 460 Installation of Outdoor Units 1P388323 1...

Page 463: ...EDMT331529A Installation Manual Installation of Outdoor Units 461 18 1P388323 1...

Page 464: ...Installation Manual EDMT331529A 462 Installation of Outdoor Units 1P388317 1...

Page 465: ...EDMT331529A Installation Manual Installation of Outdoor Units 463 18 C 1P388317 1...

Page 466: ...Installation Manual EDMT331529A 464 Installation of Outdoor Units...

Page 467: ...EDMT331529A Installation Manual Installation of Outdoor Units 465 18 C 1P388317 1...

Page 468: ...Installation Manual EDMT331529A 466 Installation of Outdoor Units 1P388317 1...

Page 469: ...EDMT331529A Installation Manual Installation of Outdoor Units 467 18 1P388317 1...

Page 470: ...Installation Manual EDMT331529A 468 Installation of Outdoor Units 1P388317 1...

Page 471: ...EDMT331529A Installation Manual Installation of Outdoor Units 469 18 2P388309 1...

Page 472: ...the air conditioning system will not operate normally 5 Power voltage of this series product is single phase 230 240V 50Hz AV4A 220 230 220V 50Hz AVE Refrigerant piping connection Refrigerant piping...

Page 473: ...ay result in oxygen deficiency Be sure to use the specified accessories and parts for installation Failure to use the specified parts may result in water leakage electric shocks fire hazards or the un...

Page 474: ...Installation Manual EDMT331529A 472 Installation of Outdoor Units C 1P388321 1 75 195...

Page 475: ...ar to the wind direction Strong wind Strong wind Air outlet Intake grille Keep adequate space and installation Exhaust grille Inlet holes Conner Outdoor unit Handles Hold the 2 handles at both sides a...

Page 476: ...Installation Manual EDMT331529A 474 Installation of Outdoor Units 1P388321 1...

Page 477: ...EDMT331529A Installation Manual Installation of Outdoor Units 475 18 1P388321 1...

Page 478: ...Installation Manual EDMT331529A 476 Installation of Outdoor Units 1P388321 1...

Page 479: ...EDMT331529A Installation Manual Installation of Outdoor Units 477 18 1P388321 1...

Page 480: ...Installation Manual EDMT331529A 478 Installation of Outdoor Units 1P388312 1...

Page 481: ...EDMT331529A Installation Manual Installation of Outdoor Units 479 18 C 1P388312 1...

Page 482: ...Installation Manual EDMT331529A 480 Installation of Outdoor Units...

Page 483: ...EDMT331529A Installation Manual Installation of Outdoor Units 481 18 C 1P388312 1...

Page 484: ...Installation Manual EDMT331529A 482 Installation of Outdoor Units 1P388312 1...

Page 485: ...EDMT331529A Installation Manual Installation of Outdoor Units 483 18 1P388312 1...

Page 486: ...Installation Manual EDMT331529A 484 Installation of Outdoor Units 1P388312 1...

Page 487: ...EDMT331529A Installation Manual Installation of Outdoor Units 485 18 2P388306 1...

Page 488: ...XQLWV WKH DLU FRQGLWLRQLQJ V VWHP ZLOO QRW RSHUDWH QRUPDOO 3RZHU YROWDJH RI WKLV VHULHV SURGXFW LV VLQJOH SKDVH a 9 5HIULJHUDQW SLSLQJ FRQQHFWLRQ 5HIULJHUDQW SLSLQJ FRQQHFWLRQ 3OHDVH UHDG WKH WKHVH 6...

Page 489: ...ied accessories and parts for installation Failure to use the specified parts may result in water leakage electric shocks fire hazards or the unit failing to operate normally Make sure to provide for...

Page 490: ...Installation Manual EDMT331529A 488 Installation of Outdoor Units C 1P388320 1 107 5 280...

Page 491: ...EDMT331529A Installation Manual Installation of Outdoor Units 489 18 1P388320 1...

Page 492: ...Installation Manual EDMT331529A 490 Installation of Outdoor Units 1P388320 1...

Page 493: ...EDMT331529A Installation Manual Installation of Outdoor Units 491 18 1P388320 1...

Page 494: ...Installation Manual EDMT331529A 492 Installation of Outdoor Units 1P388320 1...

Page 495: ...EDMT331529A Installation Manual Installation of Outdoor Units 493 18 1P388320 1...

Page 496: ...Installation Manual EDMT331529A 494 Installation of Outdoor Units 1P388311 1...

Page 497: ...EDMT331529A Installation Manual Installation of Outdoor Units 495 18 C 1P388311 1...

Page 498: ...Installation Manual EDMT331529A 496 Installation of Outdoor Units...

Page 499: ...EDMT331529A Installation Manual Installation of Outdoor Units 497 18 C 1P388311 1...

Page 500: ...and valve A R410A tank with siphon pipe Gauge Liquid side stop valve Valve A Outdoor unit Indoor unit Gas side stop valve Stop valve service port ON OFF state of the valve A and stop valves Before sta...

Page 501: ...EDMT331529A Installation Manual Installation of Outdoor Units 499 18 1P388311 1...

Page 502: ...Installation Manual EDMT331529A 500 Installation of Outdoor Units 1P388311 1...

Page 503: ...EDMT331529A Installation Manual Installation of Outdoor Units 501 18 2P388305 1...

Page 504: ...n the capacity ratio of the indoor system to the outdoor unit is more than 100 and when all the indoor units are in operation at the same time then the rated capacity of each unit will be somewhat red...

Page 505: ...nce When the equivalent piping length in cooling operation is calculated the gas pipe size is selected When the equivalent piping length in heating operation is calculated the liquid pipe size is sele...

Page 506: ...y or vertically When the size of the selected field piping is different from that of branch pipe then the connecting section should be cut with a pipe cutter as shown in the figure below When you are...

Page 507: ...the outdoor unit side of the liquid pipe header Cut the B section with a pipe cutter as shown below and connect it to the A section Connect the flared section of the field pipe to the B section Fit t...

Page 508: ...REFNET Joint and Header EDMT331529A 506 Installation of Outdoor Units 4 REFNET Joint and Header 4 1 REFNET Joint Branch Kit KHRP26A22T Unit mm KHRP26A33T Unit mm D3K05234A D3K05235B...

Page 509: ...EDMT331529A REFNET Joint and Header Installation of Outdoor Units 507 18 KHRP26A22T KHRP26A33T 2P182411 1...

Page 510: ...REFNET Joint and Header EDMT331529A 508 Installation of Outdoor Units 2P182411 1...

Page 511: ...ATION LIQUID SIDE JOINT GAS SIDE JOINT ACCESSORY REDUCER GAS SIDE 3 pcs LIQUID SIDE 2 pcs PLUGGING TUBE 1 SET INSULATION 1 SET INSTALLATION MANUAL INSULATION J D3K03629C GAS SIDE JOINT LIQUID SIDE JOI...

Page 512: ...REFNET Joint and Header EDMT331529A 510 Installation of Outdoor Units KHRP26M22H KHRP26M33H 3P113151 1C...

Page 513: ...EDMT331529A REFNET Joint and Header Installation of Outdoor Units 511 18 3P113151 1C...

Page 514: ...Caution Label EDMT331529A 512 Installation of Outdoor Units 5 Caution Label 5 1 RXYMQ4AVE 2P387669 1A...

Page 515: ...EDMT331529A Caution Label Installation of Outdoor Units 513 18 2P387669 1A...

Page 516: ...Caution Label EDMT331529A 514 Installation of Outdoor Units 2P387669 1A...

Page 517: ...EDMT331529A Caution Label Installation of Outdoor Units 515 18 2P387669 1A...

Page 518: ...Caution Label EDMT331529A 516 Installation of Outdoor Units 5 2 RXYMQ5AVE RXYMQ6AVE 2P388276 1A...

Page 519: ...EDMT331529A Caution Label Installation of Outdoor Units 517 18 2P388276 1A...

Page 520: ...Caution Label EDMT331529A 518 Installation of Outdoor Units 2P388276 1A...

Page 521: ...EDMT331529A Caution Label Installation of Outdoor Units 519 18 2P388276 1A...

Page 522: ...Caution Label EDMT331529A 520 Installation of Outdoor Units 5 3 RXYMQ8AY1 RXYMQ9AY1 2P387668 1...

Page 523: ...EDMT331529A Caution Label Installation of Outdoor Units 521 18 2P387668 1...

Page 524: ...Caution Label EDMT331529A 522 Installation of Outdoor Units 2P387668 1...

Page 525: ...EDMT331529A Caution Label Installation of Outdoor Units 523 18 2P387668 1...

Page 526: ...Caution Label EDMT331529A 524 Installation of Outdoor Units...

Page 527: ...1529A Option of Control 525 19 Part 7 Option of Control 1 Option List of Controllers 526 1 1 Operation Control System Optional Accessories 526 1 2 System Configuration 527 1 3 Building Management Syst...

Page 528: ...B61 KRP1B56 7 1 Wiring adaptor for electrical appendices 1 KRP2A62 KRP2A62 KRP2A61 KRP2A61 KRP2A53 7 2 Wiring adaptor for electrical appendices 2 KRP4AA53 KRP4AA53 KRP4AA53 KRP4AA51 KRP4AA51 KRP4A54 8...

Page 529: ...al box with earth terminal 3 blocks KJB311AA 3 Unified ON OFF controller DCS301BA61 Up to 16 groups of indoor units 128 units can be turned ON OFF individually or simultaneously and operation and malf...

Page 530: ...metre 2 3 iTM energy navigator DCM008A51 Building energy consumption is visualized Wasted air conditioning energy can be found out 2 4 BACnet client DCM009A51 BACnet equipment can be managed by intel...

Page 531: ...EDMT331529A Guide Specifications 529 20 Part 8 Guide Specifications 1 Guide Specifications 530 1 1 Indoor Unit 530 1 2 Outdoor Unit 530 1 3 Control 530...

Page 532: ...take over emergency operation Possible only with single outdoor unit systems that are equipped with two or more compressors Local setting of the outdoor unit is necessary If one of the unit in a mult...

Page 533: ......

Page 534: ......

Page 535: ......

Page 536: ...leakage electrical shock fire or explosion Use only those parts and accessories supplied or specified by Daikin Ask a qualified installer or contractor to install those parts and accessories Use of un...

Reviews: