SIS
™
Programming and Control, cont’d
MPX 866 A Media Presentation Matrix Switcher • SIS Programming and Control
4-12
PRELIMINAR
Y
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Save, directly write, name, and recall global presets
N
• If the user tries to recall a preset that is not saved, the matrix switcher responds with the error code E11.
• The following characters are invalid in preset names: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
Save current the current
confi guration as a global
preset
X1)
,
Spr
X1)]
Command character is a
comma.
Example:
9,
Spr09
]
Save current ties as preset 9.
Direct write process —
N
The
direct write of a global preset
command should always be preceded by a
clear global preset
command of that
same preset number, as shown below. In a directly-written preset, each output position’s tied input (or no tied output)
remains unchanged unless overwritten or cleared.
If you do not
clear
a global preset number before you
directly write
a global preset to that number, ties that are part of
the previous version of the specifi ed preset can unexpectedly become part of the newly-created preset.
Clear a global preset
E
+
X1)
P0*!
}
Spr
X1)]
Clear all ties in preset
X1)
.
Directly write a global
preset
E
+
X1)
P
X@
*
X#
!
X@
*
X#
%
X@
*
X#
$ ...
X@
*
X#
&
}
Enter as many ties as are
valid for this model.
The tie all (
!
), tie RGBHV (
&
),
tie video (
%
), and tie audio
(
$
) commands are all valid.
Spr
X1)]
Example:
E
+27P0*!
}
Spr27
]
E
+27P2*5!10*2$13*11%3*6&
Brackets are shown to
separate ties for clarity only.
Create global preset 27,
which ties video and audio
input 2 to output 5,
audio input 10 to output 2,
video input 13 to output 11,
and video input 3 to output 6.
Spr27
]
Recall a global preset
X1)
.
Rpr
X1)]
Command character is a
period.
Example:
5.
Rpr
X1)]
Recall preset 5, which
becomes the current
confi guration.
Write global preset name
EX1)
,
X1%
NG
}
Nmg
X1)
,
X1%]
Example:
E
1,Security 1NG
}
Nmg01,Security 1
]
Name global preset 1
“Security 1”.
Read global preset name
EX1)
NG
}
X1%]
Example:
E
2NG
}
Security 2
]
Front panel security lockout (
Executive
mode
)
Lock front panel
1X
Exe1
]
Enable
Executive
mode.
Unlock front panel
0X
Exe0
]
Disable
Executive
mode.
View front panel lock
X
X(]