Expondo Uniprodo UNI COOLER 01 User Manual Download Page 6

UNI_COOLER_03

UNI_COOLER_04

1. 

Control panel

2. 

On / Off button of the heating function

3. Wheels

4. 

Water level indicator

5. 

Horizontal jalousies

6. 

Vertical jalousies

7. 

Inlet of water and ice

8. 

Power cord

9. 

Internal filter with Honey comb structure

10.  Water tank

11.  External filter

12. Handle

13.  Water outlet

14.  Ice tank

15.  Top cover

4.2 PREPARING FOR USE

It is necessary to install the attached wheels in the device. 

Place the device in a vertical position on a flat and stable 

surface. The device is equipped with filters. Before using the 

device it is necessary to always make sure whether the filters 

are  installed  in  the  device.  The  lack  of  the  external  filter 

may cause damage to the device by getting contaminants 

into its inside. The internal filter enables functioning of the 

cooling process and additionally it also filters the air and 

moisturizes it (during the cooling process).

4.3 DEVICE USE 

Description of control panels and wireless remote controls

6

5

1

3

11

8

9

10

6
5

1

7

3

4

14

8

13

10

11

9

12

15

UNI_COOLER_01

• 

In the UNI_COOLER_01 model, the function is 

activated manually using the button (2), however, it 

will work only when the device is switched on (the 

On / Off button (1) is on – the diode A1 lights up). 

There is only one stage of heating setpoint. If heating 

was started manually, it can be operated using the (H) 

button on the remote control or on the control panel. 

Note:  Always  set  the  switch  (2)  to  the  Off  position, 

if  we  turn  off  the  whole  device  (despite  turning 

off  the  device  with  the  remote  control,  the  user 

must  approach  it  and  turn  off  the  heating  function 

manually). 

• 

The UNI_COOLER_03 model has an automatic 

activation of the heating function from the level of 

the control panel or the wireless remote control. The 

heating function has the option of the two-stage 

selection of the heating power (change of the stage 

by pressing the button (H)). You can disable the 

option by pressing the (H) button on the panel or on 

the wireless remote control.

Cooling function

• 

All models of the devices have the air cooling function.

• 

The max. cooling temperature is about 3-5 °C (only 

with air humidity <40%). Attention: If the device is 

being used in conditions with high temperatures and 

humidity of >40%, the device will not be able to lower 

the air temperature.

• 

In order to activate the function, the tank of the device 

must be filled with water and previously frozen cooling 

cartridges or ice cubes. It is forbidden to activate the 

function without the tank filled with water.

• 

Topping up the water tank:

In the UNI_COOLER_03, UNI_COOLER_01 and UNI_

COOLER_02 models, it is necessary to pull out the water 

tank and fill it with water and frozen cooling cartridges 

or ice cubes – this is shown in the picture below:

• 

In the UNI_COOLER_04 model, the water tank is 

topped up by pouring clean water and dropping ice 

cubes through the inlet hole (7). Note: It is forbidden 

to use cooling cartridges in this model! Observe 

the level of water being poured on the water level 

indicator (4).

• 

Regularly observe the water level in the tank in the 

course of the device operation. If necessary, fill up the 

water shortages.

9

11

EN 11

10

EN

A. 

On / off switch

 

A1. – information on switching the device on / off

B. 

Ventilation speed adjustment button

 

B1. – low ventilation force

 

B2. – average ventilation force

 

B3. – strong ventilation force

C. 

Button for switching on the automatic movement of 

the jalousie

 

C1. –information on activation of the jalousie 

movement function

D. 

Ventilation mode selection button

 

D1. – normal mode

 

D2. – natural mode

 

D3. – night mode

E. Timer

 

E1. – time of automatic device shutdown

F. 

Button for switching on the cooling function

 

F1. – information on activation of the cooling 

function

G. 

Button for switching on the air ionization function

 

G1. – information on activation of the ionization 

function

UNI_COOLER_04

UNI_COOLER_03

G1

G

E
F

H

C

B

A1

A

E1

C1

F1 H1 H2 D1 D3

B3

B2

B1

E1 C1

B2

E

C

B/D

F

A

D2

D3

B3

F1

B1

A1

E1

D1

D2

D3 C1 F1

B1

B2

B3

F

E

D

C

B

A

A1

A

F
C
E

B

D

UNI_

COOLER_04

A

F

B/D

E

C

F

E

D

G

H

UNI_

COOLER_03

B/D

H

B/D

E

C

F

A

UNI_

COOLER_01

UNI_

COOLER_02

F

E

H

C

B/D

A

H3

D2

D3 C1 F1

B1

B2

B3

A1

E1

UNI_COOLER_02

H. 

Button for switching on the heating function

 

H1. – low heating power (UNI_COOLER_03 model)

 

H2. – high heating power (UNI_COOLER_03 model)

 

H3. – heating enabled (Model UNI_COOLER_01)

The elements marked with the numbering A1 – H3 are 

diodes informing about the activation of a given device 

function. If the function is active, the diode lights up, 

otherwise it is off.

Heating function

• 

The UNI_COOLER_01 AND UNI_COOLER_03 models 

have the air heating function.

Setting the operation time

The operating time of the device is set by single pressing the 

button (E). Each pressing causes to add 1h starting from 1 to 

12h (in the case of the UNI_COOLER_04 model, addition of 

0.5h starting from 0.5 to 7.5h). 

Operation

• 

Connect the device to the power supply source.

• 

Switch on the device with the On / Off button (A).

• 

Set the device operation manner according to own 

preferences. The number of available options from 

among the operating modes depends on the device 

model.

• 

Single pressings of the option data buttons cause their 

activation, the next pressings in case of the buttons 

with the single selection causes deactivation of the 

given option. In the case of buttons with possibilities 

of selection of the functioning option, single pressings 

will cause jumping between subsequent options, after   

reviewing all options, the next pressing will cause 

deactivation of the option. 

Depending on the device model, the following options are 

available:

1. 

COOL/ COOL AIR– cooling option

2. 

TIMER – minute timer

3. 

MODE – selection of the ventilation mode

4. 

SWING – switching on / off the jalousie movement

5. 

SPEED – ventilation speed regulation

6. 

WARM – heating option

7. 

IONIZER – switching on / off the ionization function

• 

The user has the possibility to manually set the 

ventilation angle (manually setting horizontal 

jalousies).

• 

In case of operating the device with a remote control, 

it is necessary to direct the remote control transmitter 

towards the device.

• 

Always turn off the device after the end of its use. 

It is best to disconnect the device from the power 

supply source.

• 

In case of moving the device to another location, it 

is necessary to use the handles if they are installed 

in the device and the wheels. The water tank must 

be emptied for the period of transport. Transport the 

device only and exclusively in the vertical position.

4.4 CLEANING AND MAINTENANCE

• 

Before cleaning, maintenance and when not in use, 

make sure the power cable is disconnected and the 

device has cooled down.

• 

Use cleaners without corrosive substances to clean 

each surface.

• 

Clean the device with a soft cloth. It is forbidden to 

pour water on the device. 

• 

Regularly clean the filters installed in the device. 

Cleaning the external and internal filter: 

Dismantle the external filter by unscrewing it from the back 

part  of  the  device  housing.  Dismantling  the  external  filter 

(11)  will  enable  access  to  the  internal  filter  with  a  honey 

comb structure (9).

03.12.2018

Summary of Contents for Uniprodo UNI COOLER 01

Page 1: ...RATIVE AIR COOLER UNI_COOLER_01 UNI_COOLER_02 UNI_COOLER_03 UNI_COOLER_04 USER MANUAL BEDIENUNGSANLEITUNG MANUEL D UTILISATION ISTRUZIONI PER L USO MANUAL DE INSTRUCCIONES INSTRUKCJA OBS UGI N VOD K P...

Page 2: ...e der Ger uschemission entstehende Risiko auf dem niedrigsten Niveau gehalten wird ERL UTERUNG DER SYMBOLE HINWEIS In der vorliegenden Anleitung sind Beispielbilder vorhanden die von dem tats chlichen...

Page 3: ...ngsgem funktioniert Ger te die per Schalter nicht gesteuert werden k nnen sind gef hrlich und m ssen repariert werden c Nicht verwendete Werkzeuge sind au erhalb der Reichweite von Kindern sowie von P...

Page 4: ...er Der Wassertank muss w hrend des Transports entleert werden Transportieren Sie das Ger t nur in vertikaler Position Reinigen Sie die Filter mit Wasser und einem milden Reinigungsmittel Der Au enfilt...

Page 5: ...ce must not be used in locations with high humidity such as close to pools in bathrooms etc e It is forbidden to set the device in the immediate vicinity of the electrical socket 3 2 SAFETY AT THE WOR...

Page 6: ...of the jalousie movement function D Ventilation mode selection button D1 normal mode D2 natural mode D3 night mode E Timer E1 time of automatic device shutdown F Button for switching on the cooling fu...

Page 7: ...ga sobie prawo dokonywania zmian zwi zanych z podwy szeniem jako ci Uwzgl dniaj c post p techniczny i mo liwo ograniczenia ha asu urz dzenie zaprojektowano i zbudowano tak aby ryzyko jakie wynika z em...

Page 8: ...iadczonych u ytkownik w d Utrzymuj urz dzenie w dobrym stanie technicznym Sprawdzaj przed ka d prac czy nie posiada uszkodze og lnych lub zwi zanych z elementami ruchomymi p kni cia cz ci i element w...

Page 9: ...cja pr dko ci nawiewu 6 WARM opcja grzania 7 IONIZER w czanie wy czanie funkcji jonizacji U ytkownik ma mo liwo manualnego ustawienia k ta nawiewu r czne ustawianie aluzji poziomych W przypadku obs ug...

Page 10: ...n vyhnout se pr ci se za zen m ve vlhk m prost ed pou vejte p itom proudov chr ni RCD Pou v n RCD sni uje nebezpe razu elektrick m proudem d Za zen nepou vejte na m stech s velmi vysokou vlhkost jako...

Page 11: ...sknut nab dku vypne V z vislosti na modelu za zen jsou dostupn nab dky 1 COOL COOL AIR nab dka chlazen 2 TIMER asova 3 MODE v b r re imu proud n vzduchu 4 SWING zapnut vypnut zata en otev en aluzi 5 S...

Page 12: ...l appareil proximit imm diate d une prise lectrique 3 1 S CURIT SUR LE LIEU DE TRAVAIL a N utilisez pas l appareil dans des zones risque d explosion par exemple en pr sence de liquides inflammables de...

Page 13: ...i rement le niveau d eau dans le r servoir pendant le fonctionnement Si besoin ajoutez l eau manquante R glage de la dur e de fonctionnement La dur e de fonctionnement de l appareil est r gl e en appu...

Page 14: ...x350 260x32x310 Dimensioni filtri esterni mm 300x425 320x330 Dimensioni mm 380x310x750 393x298x640 Peso kg 7 93 6 9 1 DESCRIZIONE GENERALE Questo manuale stato pensato per consentire di utilizzare il...

Page 15: ...zo e La riparazione e la manutenzione del dispositivo devono essere eseguite esclusivamente da personale qualificato e impiegando soltanto parti di ricambio originali Ci rende questo refrigeratore ad...

Page 16: ...ne staccare la spina dal dispositivo e lasciar raffreddare il dispositivo Nel modello UNI_COOLER_04 riempire il serbatoio con acqua pulita e aggiungere i cubetti di ghiaccio attraverso il punto d ingr...

Page 17: ...dad por ejemplo en proximidad a piscinas cuartos de ba o etc e Se proh be colocar este aparato en las inmediaciones de una toma de corriente 3 2 SEGURIDAD EN EL PUESTO DE TRABAJO a No utilice el apara...

Page 18: ...ci n sobre la activaci n de la funci n de movimiento de la celos a D Mando de selecci n para el modo de suministro de aire D1 modo sencillo D2 modo natural D3 modo noche E Temporizador E1 tiempo autom...

Page 19: ...ovecharlos contribuyen de forma importante a proteger el medio ambiente Los puntos de reciclaje y las administraciones locales le proveer n de informaci n al respecto 9 11 NAMEPLATE TRANSLATIONS 1 2 3...

Page 20: ...E CZ T mto potvrzujeme e v echy produkty uveden v t to u ivatelsk p ru ce disponuj CE prohl n m o shod FR Par la pr sente nous confirmons que les appareils pr sent s dans ce mode d emploi sont conform...

Page 21: ...Verf gung stehenden M glichkeiten der R ckgabe oder Sammlung von Altger ten 1 RICHTLINIE 2002 96 EG DES EUROP ISCHEN PARLAMENTS UND DES RATES BER ELEKTRO UND ELEKTRONIK ALTGER TE 2 Gesetz ber das Inve...

Reviews: