
System Tab
SONET/SDH Application
373
Clock Synchronization
³
LBO
(Line Build Out): Allows the selection of the interface Line Build
Out that meets the interface requirements over the full range of cable
lengths. Available with DS1 interface only. Choices are:
+3.0 dBdsx
(533-655 ft)
,
+2.4 dBdsx (399-533 ft)
,
+1.8 dBdsx (266-399 ft)
,
+1.2 dBdsx (133-266 ft)
, and
+0.6 dBdsx (0-133 ft)
.
³
Line Coding
: Allows the selection of the interface line coding. Choices
are
AMI
and
B8ZS
for DS1;
AMI
and
HDB3
for E1.
Note:
Line Coding is not available with 2 MHz interface.
³
Framing
: Allows the selection of the interface framing. Choices are
SF
and
ESF
for DS1;
PCM 30
,
PCM 30 CRC-4
,
PCM 31
, and
PCM 31 CRC-4
for E1.
Note:
Framing is not available with 2 MHz interface.
³
Clock Mode
: Allows the selection of the source clock that will be used
to generate the clock on the selected interface type. Choices are:
Internal
: Internal clock of the unit (STRATUM 3).
Recovered
: Clock from the test optical/electrical port input signal.
Backplane
: 8 kHz clock from another module on the FTB-200. Note
that the other module must support the backplane clock feature and
must be enabled (refer to
Backplane
on page 378 for more
information).
Summary of Contents for FTB-8100 Series
Page 1: ...User Guide FTB 8100 Series for FTB 200 SONET SDH Application...
Page 18: ......
Page 22: ......
Page 24: ......
Page 94: ......
Page 108: ......
Page 178: ......
Page 224: ......
Page 260: ......
Page 312: ......
Page 352: ......
Page 382: ......
Page 412: ......
Page 490: ......
Page 500: ......