Common Tabs
368
FTB-8100 Series Transport Blazer
Performance Monitoring (PM)
For M.2100 ISM: Gives the count of the seconds within which
anomalies (frame bit errors, CRC block errors, etc.) are
≥
Y or at least
one defect occurred. Y depends on the type of DSn/PDH signal as
described in the following table.
³
BBE
(Background Block Error) (G.828 and G.829 Line): Gives the count
of Errored Blocks not occurring as part of an SES.
Signal
SES Threshold
DS1 (SF)
8 frame bit errors (Near-End)
DS1 (ESF)
320 CRC-6 block errors (Near-End) 320 CRC-6 block errors
(Far-End, if FDL enabled)
E1 (Framed without CRC-4) 28 frame bit errors (Near-End)
E1 (Framed with CRC-4)
805 CRC-4 block errors (Near-End) 805 E-bit errors
(Far-End)
DS3 (M13)
2444 P-bit errors (Near-End) or 5 F-bit errors (Near-End)
DS3 (C-bit Parity)
2444 P-bit errors (Near-End) or 5 F-bit errors
(Near-End) 2444 FEBE errors (Far-End)
E2 (Framed)
41 frame bit errors (Near-End)
E3 (Framed)
52 frame bit errors (Near-End)
E4 (Framed)
69 frame bit errors (Near-End)
Summary of Contents for FTB-8100 Series