SDH Tabs
SONET/SDH Application
279
HOP OH TX/RX (SDH)
HOP OH TX/RX (SDH)
The
HOP OH TX
allows changing the high order path transport overhead
information to be transmitted while the
HOP OH RX
allows verification of
the high order path transport overhead information received.
Press
Main
,
Test
,
SDH
,
HOP
, and
OH TX/RX
.
Path Overhead
³
Binary
: Allows either displaying all overhead values in binary (when
the Binary check box is selected) or hexadecimal (when the Binary
check box is cleared). This Binary check box is cleared by default.
³
J1
: Trace. J1 is only available when
Enable Trace
from the
HOP TX
(SDH)
on page 272 is disabled.
³
B3
: BIP-8. This byte is not programmable from the HOP OH TX tab.
³
C2
: Path Signal Label. Entering a C2 byte will automatically update the
Path Signal Label (C2) selection and vice versa.
³
G1
: Path Status
³
F2
: User Channel