SONET Tabs
174
FTB-8100 Series Transport Blazer
Section OH TX/RX (SONET)
Section OH TX/RX (SONET)
The
Section OH TX
allows changing the transport overhead information to
be transmitted while the
Section OH RX
allows verification of the transport
overhead information received. Refer to
Glossary
on page 413 for detailed
overhead information.
Press
Main
,
Test
,
SONET
,
Section
, and
OH TX/RX
.
Section Overhead
³
Timeslot
: Select the timeslot number that will be used for verification.
Choices are
1
to
3
,
12
,
48
, or
192
depending on the OC-N interface
selected. The default setting is
1
.
³
Binary
: Allows either displaying all overhead values in binary (when
the Binary check box is selected) or hexadecimal (when the Binary
check box is cleared). This Binary check box is cleared by default.
³
A1
and
A2
: Framing. The value should be hexadecimal
F6
for A1 and
28
for A2.