Port RX (Optical Interfaces)
Frequency Analysis
The FTB-8100 Series allows the following frequency monitoring range.
Actual Frequency (bps)
indicates the frequency of the input signal in bps.
Frequency Offset
indicates the offset between the standard rate
specification and the rate of the input signal.
Max. Negative Offset
indicates the offset between the standard rate
specification and the smallest rate recorded from the received signal.
Max. Positive Offset
indicates the offset between the standard rate
specification and the largest rate recorded from the received signal.
Offset Unit
allows the selection of the frequency offset unit. Choices are
bps
and
ppm
. The default setting is
ppm
.
Interface
Measurement range
OC-3/STM-1
155520000 ±100 ppm
OC-12/STM-4
622080000 ±100 ppm
OC-48/STM-16
2488320000 ±100 ppm
OTU1
2666057143 ±100 ppm
OC-192/STM-64
9953280000 ± 100 ppm
OTU2
10709225316 ±100 ppm
OTU1e
11049107143 ±120 ppm
OTU2e
11095727848 ±120 ppm
OTU1f
11270089286 ± 120 ppm
OTU2f
11317642405 ± 120 ppm