Metadata_Preset
Here you select which Metadata preset you want to activate. Editing the preset
will be live.
#MD_Preset_Name
To help remember which preset is used for what cases, you can name your
active preset with this setting (maximum of 16 characters).
#ProgramConfig
This item sets the program configuration. Can be one of the following values:
•
7.1
•
4x2
•
5.1+2
•
3x2
•
5.1
•
2+2
•
Ext_Meta (use value as set in metadata source).
#Frame_Rate
With this you can set the metadata ‘framerate’ value. Can be 23.98, 24, 25,
29.97, 30, auto or set to use the setting in the external metadata input (Ext_
meta).
#MD_Prog_1
Since a bitstream can contain up to 4 separate audio streams (e.g. when the
program config is 4x2), you can have 4 separate metadata sets. With MD_Prog_1
you select which metadata set should be used for the first audio program. Can
be any set from A to H. You can also choose to use the program as set in the
metadata source (Ext_Meta), in which case the entire program is kept and no
preset is used. Default is set A.
#MD_Prog_2
With MD_Prog_2 you select which metadata set should be used for the second
audio program (if there is any). Can be any set from A to H. You can also choose
to use the program as set in the metadata source (Ext_Meta), in which case the
entire program is kept and no preset is used. Default is set B.
#MD_Prog_3
With MD_Prog_3 you select which metadata set should be used for the third
audio program (if there is any). Can be any set from A to H. You can also choose
to use the program as set in the metadata source (Ext_Meta), in which case the
entire program is kept and no preset is used. Default is set C.
#MD_Prog_4
With MD_Prog_4 you select which metadata set should be used for the fourth
audio program (if there is any). Can be any set from A to H. You can also choose
to use the program as set in the metadata source (Ext_Meta), in which case the
entire program is kept and no preset is used. Default is set D.
5.13.
Metadata Prog
Setting
Description
MD_Prog_Set
With this item you can select the metadata set whose parameters you want to
adjust. Options are
A
through
H
. Default is parameter set
A
. All following items
preceded by ‘#’ are workers of this set. Unless this parameter is set to a metadata
set that is currently in use, changing the metadata settings will have no direct
effect on the output.
30
| November 2021 | Issue 1.00.B
Summary of Contents for Synapse GED100
Page 2: ......
Page 8: ......
Page 26: ...18 November 2021 Issue 1 00 B ...
Page 27: ...INSTALLATION AND OPERATION MANUAL Synapse GED100 5 Settings Menu 19 ...
Page 28: ...20 November 2021 Issue 1 00 B ...
Page 29: ...INSTALLATION AND OPERATION MANUAL Synapse GED100 5 Settings Menu 21 ...
Page 57: ...9 Block Schematic INSTALLATION AND OPERATION MANUAL Synapse GED100 9 Block Schematic 49 ...
Page 70: ...62 November 2021 Issue 1 00 B ...
Page 72: ......
Page 73: ......
Page 74: ......