DEPOLOX
®
5 E flow cell
Maintenance
5.
55
5.9
Cleaning flow rate monitor and check valve
Proceed as follows:
1
Switch off the power supply.
2
Drain the sample water inlet and outlet line.
3
Remove the housing cover of the DEPOLOX
®
5 E flow cell.
4
Dismantle the filter unit.
5
Carefully pull the complete non-return ball valve housing (A) down
and out.
6
Turn the non-return ball valve housing upside down and catch the
flow ball (B) or if the ball is jammed, release it with a slight knock.
7
Use a suitable blunt tool to push out the ball seat (D) and glass ball
(C) against the direction of flow.
8
Clean the empty check valve housing, flow ball, ball seat and glass
ball with distilled water.
9
During reassembly, make sure that the ball seat and ball are cor
-
rectly positioned.
10
To help push the assembled check valve housing back into the con
-
trol valve, slightly lubricate the gaskets with the supplied Unisilikon
grease.
11
Check that the non-return ball valve housing is correctly positioned
through the guide lugs on the housing.
12
Fit the filter unit again.
13
Refit and engage the housing cover of the DEPOLOX
®
5 E flow cell.
14
Reconnect the sample water inlet and outlet lines.
15
Re-establish the power supply.
Image 3 Detail: installation location of check valve housing
Image 4 Cross-section of check valve-housing
A Check valve housing (overall)
B Flow cone
C Spherical seat
D Glass ball
5.10
Cleaning
Do not use aggressive cleaning agents (e.g., alcohol, abrasive cleaners)!
We recommend a damp cloth moistened with a commercially available
neutral detergent.
A
top
bottom
B
C
D
Summary of Contents for WALLACE & TIERNAN DEPOLOX 5 E 700 P Series
Page 1: ...WALLACE TIERNAN DEPOLOX 5 E FLOW CELL INSTRUCTION MANUAL...
Page 56: ...56 WT 050 810 040 DE IM 0519 Maintenance DEPOLOX 5 E flow cell 5...
Page 72: ...72 WT 050 810 040 DE IM 0519 Declarations and certificates DEPOLOX 5 E flow cell 7...
Page 76: ...76 WT 050 810 040 DE IM 0519 Declarations and certificates DEPOLOX 5 E flow cell 7...
Page 80: ...80 WT 050 810 040 DE IM 0519 Index DEPOLOX 5 E flow cell 8...