16
WT.050.810.040.DE.IM.0519
Description
DEPOLOX
®
5 E flow cell
3.
3.2.3
Configuration options
Designation
DEPOLOX
®
5 E
Non-pressurized
version
DEPOLOX
®
5 E
pressurized
version
DEPOLOX
®
5 E
pressurized version with
cell body cover
W3T417351 (optional)
A 3-electrode measuring cell (free chlorine)
B Membrane sensor for total chlorine TC3 CAN
C Conductivity sensor
D Redox combined measuring and reference electrode
E LED glow stick
F pH combined measuring and reference electrode
3-electrode measuring cell
(free chlorine)
X
X
X
Membrane sensor for total
chlorine TC3 CAN
X
-
X
pH combined measuring and
reference electrode
X
X
X
Redox combined measuring
and reference electrode
X
X
X
Conductivity sensor
X
X
X
Sample water temperature
(multi-sensor)
X
X
X
Flow rate monitor (multi-sen
-
sor)
X
X
X
Sample water earthing
(multi-sensor)
X
X
X
Sample water fine filter (fine
filter)
(X)
Only when using
membrane sensors
-
(X)
Only when using
membrane sensors
LED glow stick
X
X
X
Shut-off ball valve at sample
water inlet
X
X
X
Shut-off ball valve at sample
water outlet
-
X
X
A
B
D
E
F
C
A C
F E D
A
B
D
E
F
C
Summary of Contents for WALLACE & TIERNAN DEPOLOX 5 E 700 P Series
Page 1: ...WALLACE TIERNAN DEPOLOX 5 E FLOW CELL INSTRUCTION MANUAL...
Page 56: ...56 WT 050 810 040 DE IM 0519 Maintenance DEPOLOX 5 E flow cell 5...
Page 72: ...72 WT 050 810 040 DE IM 0519 Declarations and certificates DEPOLOX 5 E flow cell 7...
Page 76: ...76 WT 050 810 040 DE IM 0519 Declarations and certificates DEPOLOX 5 E flow cell 7...
Page 80: ...80 WT 050 810 040 DE IM 0519 Index DEPOLOX 5 E flow cell 8...