App. A - 10
Appendix A Technical Description
A
590SP Digital Product Manual
C7/Digital Input 2
This terminal is for the RAMP HOLD signal. If the input is held ON (+24V), the RAMP GENERATOR OUTPUT is
frozen at the last value regardless of the ramped setpoint input. When OFF (0V), the ramp output follows the RAMPED
SETPOINT INPUT at the rate or change determined by the acceleration, deceleration ramp time, and "S-ramp" parameters.
C8/Digital Input 3
This terminal is the CURRENT DEMAND ISOLATE, which changes the drive operation from speed control to current
control. When DIGITAL INPUT 3 is ON (+24V), ANALOG INPUT 2 provides the current demand and the speed
loop is disconnected; when OFF (0V), the speed loop is in control and ANALOG INPUT 2 is an auxiliary speed setpoint.
C9/+24 VDC Supply
This terminal is for current output, which can be used to activate the DIGITAL INPUT, PROGRAM STOP, and
COAST STOP terminals, and other +24 VDC devices. It has a maximum output of 700mA for a single board power
supply.
NOTE: The load on terminal C9 combined with the other +24V loads must not exceed 700mA. See the
Electrical Ratings information earlier in this appendix.
D1, D2/External AC Field Supply
The field bridge is normally supplied off the main input power. If the motor field requires a different AC supply
voltage, move jumpers JP1 and JP2 from position 2 and 3 to 1 and 2 and connect an external field supply to these
terminals.
Rating: 300 VAC maximum, 3 amps maximum.
D3,D4/Motor Field
These terminals provide the connection point for the motor field. When connected as a full wave rectifier circuit, the
DC output voltage is 0.90 X AC field supply input. If connected as a half wave rectifier, the DC output voltage is 0.45
X AC field supply input.
Rating: 250 VDC, 3 amp maximum.
D5, D6/Drive Start Relay Contact
These terminals provide access to the normally-opened contact of the drive's internal start relay. This contact allows
the drive to control an external main contactor. If the main contactor coil voltage matches the drive supply power, the
coil may be powered internally by setting jumpers JP3 and JP4 to positions 2 and 3 and connecting the coil between
terminals D5 (AC coil supply) and D6 (neutral). If the coil voltage differs from the main supply, set the jumpers to
positions 1 and 2 and connect the required supply voltage in series to the coil through D5 and D6.
Rating: 250 VAC, 3 amps maximum. Use a slave contactor if coil inrush exceeds maximum rating.
D7 and D8/Control Auxilary Supply
These terminals allow control power to be applied externally to the drive when the main supply exceeds 240 VAC.
Move jumpers JP5 and JP6 from positions 1 and 2 to 2 and 3 and connect the supply line terminal D7 and supply
neutral to D8.
Terminal rating: 250 VAC, 3 amps maximum.
A+, A-/Armature
These terminals and the associated ground terminal provide the connection point for the motor armature. The screw
terminals are rated to 40 amps maximum.
L1, L2/Single Phase Supply
Connection for the single-phase input supply. The nominal supply range: 110 or 440 VAC. The screw terminals are
rated to 40 amps maximum.
Summary of Contents for 590SP
Page 2: ......
Page 16: ...1 4 590SP Digital Product Manual 1 Chapter 1 Introduction ...
Page 18: ...2 2 2 590SP Digital Product Manual Chapter 2 Identification ...
Page 31: ...Figure 3 3 Wiring Circuit Diagram for 590SP Digital Drive ...
Page 41: ...4 10 4 590SP Digital Product Manual Chapter 4 Start up and Adjustment DIGTIAL ...
Page 67: ...6 590SP Digital Product Manual Chapter 6 Service and Maintenance 6 6 ...
Page 89: ...B Appendix B Using the Man Machine Interface App B 4 590SP Digitial Product Manual ...
Page 125: ...Appendix C Setup Parameters 590 DRV Digital DC Drive Product Manual App C 36 C ...
Page 149: ...Appendix D I O Configuration System Menu App D 24 D 590SP Digital DC Drive Product Manual ...
Page 150: ...t t t t Figure D 20 590SP Digital Software Block Diagram ...
Page 160: ...590SP Digital Product Manual App E 10 E Appendix E MMI Parameter List ...
Page 168: ...Appendix G RS232 System Port P3 590SP Digital Product Manual App G 6 G ...
Page 194: ...Appendix H RS422 Communications Ports P1 P2 590SP Digital Product Manual App H 26 H ...
Page 220: ...App L 6 590SP Digital Product Manual L Appendix L 590SP DRV Option ...
Page 221: ...Figure L 5 Wiring Circuit Diagram for 590SP Digital DRV Drive ...
Page 259: ...590SP Digital Product Manual App M 38 Appendix M Special Blocks and Application Notes M ...