Appendix J Parameter List by Menu
590SP Digital Product Manual
App. J - 3
J
TAG PARAMETER NAME
MENU
DEFAULT
MIN
MAX
16
PROP. GAIN
SETUP PARAMETERS::CURRENT LOOP
45
0 20000 RW
201
REGEN MODE
SETUP PARAMETERS::CURRENT LOOP
ENABLED
0
1 RW
93
IMAX BRK1(SPD1)
SETUP PARAMETERS::CURRENT PROFILE
200.00%
0 20000 RW
33
IMAX BRK2(SPD2)
SETUP PARAMETERS::CURRENT PROFILE
200.00%
0 20000 RW
32
SPD BRK1 (LOW)
SETUP PARAMETERS::CURRENT PROFILE
100.00%
0
10000 RW
31
SPD BRK2 (HIGH)
SETUP PARAMETERS::CURRENT PROFILE
100.00%
0
10000 RW
111
5703 RCV ERROR
SETUP PARAMETERS::INHIBIT ALARMS
ENABLED
0
1 RW
92
ENCODER ALARM
SETUP PARAMETERS::INHIBIT ALARMS
ENABLED
0
1 RW
81
SPEED FBK ALARM
SETUP PARAMETERS::INHIBIT ALARMS
ENABLED
0
1 RW
28
STALL TRIP
SETUP PARAMETERS::INHIBIT ALARMS
INHIBITED
0
1 RW
305
TRIP RESET
SETUP PARAMETERS::INHIBIT ALARMS
TRUE
0
1 RW
225
CRAWL SPEED
SETUP PARAMETERS::JOG/SLACK
10.00%
-10000
10000 RW
218
JOG SPEED 1
SETUP PARAMETERS::JOG/SLACK
5.00%
-10000
10000 RW
219
JOG SPEED 2
SETUP PARAMETERS::JOG/SLACK
-5.00%
-10000
10000 RW
228
MODE
SETUP PARAMETERS::JOG/SLACK
FALSE
0
1 RW
355
RAMP RATE
SETUP PARAMETERS::JOG/SLACK
1.0 SECS
1
6000 RW
253
TAKE UP 1
SETUP PARAMETERS::JOG/SLACK
5.00%
-10000
10000 RW
254
TAKE UP 2
SETUP PARAMETERS::JOG/SLACK
-5.00%
-10000
10000 RW
257
DECREASE RATE
SETUP PARAMETERS::RAISE/LOWER
10.0 SECS
1
6000 RW
307
EXTERNAL RESET
SETUP PARAMETERS::RAISE/LOWER
FALSE
0
1 RW
256
INCREASE RATE
SETUP PARAMETERS::RAISE/LOWER
10.0 SECS
1
6000 RW
262
LOWER INPUT
SETUP PARAMETERS::RAISE/LOWER
FALSE
0
1 RW
259
MAX VALUE
SETUP PARAMETERS::RAISE/LOWER
100.00%
-30000 30000 RW
258
MIN VALUE
SETUP PARAMETERS::RAISE/LOWER
-100.00%
-30000 30000 RW
261
RAISE INPUT
SETUP PARAMETERS::RAISE/LOWER
FALSE
0
1 RW
255
RESET VALUE
SETUP PARAMETERS::RAISE/LOWER
0.00%
-30000 30000 RW
266
% S-RAMP
SETUP PARAMETERS::RAMPS
2.50%
0
10000 RW
287
AUTO RESET
SETUP PARAMETERS::RAMPS
ENABLED
0
1 RW
288
EXTERNAL RESET
SETUP PARAMETERS::RAMPS
DISABLED
0
1 RW
126
MIN SPEED
SETUP PARAMETERS::RAMPS
0.00%
0
10000 RW
2
RAMP ACCEL TIME
SETUP PARAMETERS::RAMPS
10.0 SECS
1
6000 RW
3
RAMP DECEL TIME
SETUP PARAMETERS::RAMPS
10.0 SECS
1
6000 RW
118
RAMP HOLD
SETUP PARAMETERS::RAMPS
OFF
0
1 RW
5
RAMP INPUT
SETUP PARAMETERS::RAMPS
0.00%
-10000
10000 RW
286
RAMPING THRESH.
SETUP PARAMETERS::RAMPS
0.50%
0
10000 RW
422
RESET VALUE
SETUP PARAMETERS::RAMPS
0.00%
-30000 30000 RW
131
DEADBAND WIDTH
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
0
10000 RW
420
DIVIDER 0
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
419
DIVIDER 1
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
309
INPUT 0
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
-20000 20000 RW
100
INPUT 1
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
-20000 20000 RW
423
INPUT 2
SETUP PARAMETERS::SETPOINT SUM 1
0.00%
-20000 20000 RW
375
LIMIT
SETUP PARAMETERS::SETPOINT SUM 1
105.00%
0 20000 RW
208
RATIO 0
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
6
RATIO 1
SETUP PARAMETERS::SETPOINT SUM 1
1
-30000 30000 RW
292
SIGN 0
SETUP PARAMETERS::SETPOINT SUM 1
POSITIVE
0
1 RW
8
SIGN 1
SETUP PARAMETERS::SETPOINT SUM 1
POSITIVE
0
1 RW
427
DIAMETER
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
0.00%
0
10000 RO
463
EXTERNAL RESET
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
DISABLED
0
1 RW
424
LINE SPEED
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
0.00%
-10500
10500 RW
425
MIN DIAMETER
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
10.00%
0
10000 RW
426
MIN SPEED
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
5.00%
0
10000 RW
453
RAMP RATE
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
5.0 SECS
1
6000 RW
437
REEL SPEED
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
0.00%
-10500
10500 RW
462
RESET VALUE
SETUP PARAMETERS::SPECIAL BLOCKS::DIAMETER CALC.
10.00%
0
10000 RW
401
DERIVATIVE TC
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.000 SECS
0
10000 RW
418
DIVIDER 1
SETUP PARAMETERS::SPECIAL BLOCKS::PID
1
-30000 30000 RW
414
DIVIDER 2
SETUP PARAMETERS::SPECIAL BLOCKS::PID
1
-30000 30000 RW
408
ENABLE
SETUP PARAMETERS::SPECIAL BLOCKS::PID
ENABLED
0
1 RW
403
FILTER T.C.
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.100 SECS
0
10000 RW
410
INPUT 1
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.00%
-30000 30000 RW
411
INPUT 2
SETUP PARAMETERS::SPECIAL BLOCKS::PID
0.00%
-30000 30000 RW
409
INT. DEFEAT
SETUP PARAMETERS::SPECIAL BLOCKS::PID
OFF
0
1 RW
402
INT. TIME CONST.
SETUP PARAMETERS::SPECIAL BLOCKS::PID
5.00 SECS
1
10000 RW
474
MIN PROFILE GAIN
SETUP PARAMETERS::SPECIAL BLOCKS::PID
20.00%
0
10000 RW
Summary of Contents for 590SP
Page 2: ......
Page 16: ...1 4 590SP Digital Product Manual 1 Chapter 1 Introduction ...
Page 18: ...2 2 2 590SP Digital Product Manual Chapter 2 Identification ...
Page 31: ...Figure 3 3 Wiring Circuit Diagram for 590SP Digital Drive ...
Page 41: ...4 10 4 590SP Digital Product Manual Chapter 4 Start up and Adjustment DIGTIAL ...
Page 67: ...6 590SP Digital Product Manual Chapter 6 Service and Maintenance 6 6 ...
Page 89: ...B Appendix B Using the Man Machine Interface App B 4 590SP Digitial Product Manual ...
Page 125: ...Appendix C Setup Parameters 590 DRV Digital DC Drive Product Manual App C 36 C ...
Page 149: ...Appendix D I O Configuration System Menu App D 24 D 590SP Digital DC Drive Product Manual ...
Page 150: ...t t t t Figure D 20 590SP Digital Software Block Diagram ...
Page 160: ...590SP Digital Product Manual App E 10 E Appendix E MMI Parameter List ...
Page 168: ...Appendix G RS232 System Port P3 590SP Digital Product Manual App G 6 G ...
Page 194: ...Appendix H RS422 Communications Ports P1 P2 590SP Digital Product Manual App H 26 H ...
Page 220: ...App L 6 590SP Digital Product Manual L Appendix L 590SP DRV Option ...
Page 221: ...Figure L 5 Wiring Circuit Diagram for 590SP Digital DRV Drive ...
Page 259: ...590SP Digital Product Manual App M 38 Appendix M Special Blocks and Application Notes M ...