Appendix C Setup Parameters
590 DRV Digital DC Drive Product Manual
App. C - 20
C
SETPOINT SUM 1
SETPOINT SUM 1 allows the summing and scaling of three analog inputs to produce
SPT. SUM OUTPUT.
Note: This block is ignored by the drive unless SYSTEM::
CONFIGURE I/O:: BLOCK DIAGRAM:: SPT SUM 1 DEST is
connected to a nonzero tag. The default connection is to tag 289.
Inputs and Outputs
ANALOG I/P 1, terminal A2, is the default input. The default output, SPT. SUM
OUTPUT, connects to SETPOINT 1 in the speed loop.
590SP DC DRIVE
MENU LEVEL
MENU LEVEL
DIAGNOSTICS
MENU LEVEL
SETUP PARAMETERS
SETUP PARAMETERS
RAMPS
SETUP PARAMETERS
SETPOINT SUM 1
M
M
Description
INPUT 0 and INPUT 1 have individual ratio and divider scalers, and signs. INPUT 1 has an additional deadband
function set by DEADBAND WIDTH. When the input is within the deadband, the output clamps to zero to ignore any
noise. This parameter is useful when digital setpoints are used (for example from a 5703, serial communications, or
the RAISE LOWER function block). The inputs have symmetrical limits set by LIMIT. INPUT 2 has no scaling or
limits.
The output after INPUT 0, INPUT 1, and INPUT 2 are summed is also clamped by LIMIT before producing SPT.
SUM OUTPUT.
Parameters
Tag Parameter
Description
Range
Default
6
RATIO 1
Multiplicative scaling for INPUT 1.
±3.0000
1.0000
208
RATIO 0
Multiplicative scaling for INPUT 0.
±3.0000
1.0000
8
SIGN 1
Polarity for INPUT 1.
POSITIVE/NEGATIVE
POSITIVE
292
SIGN 0
Polarity for INPUT 0.
POSITIVE/NEGATIVE
POSITIVE
419
DIVIDER 1
Divider scaling for INPUT 1.
±3.0000
1.0000
420 DIVIDER 0
Divider scaling for INPUT 0.
±3.0000
1.0000
131
DEADBAND WIDTH Range within which the output is clamped at zero.
0.0 to 100.0%
0.0%
375
LIMIT
Symmetrical limit for intermediate scaling and the total
0.00 to 200.00%
105.00%
output.
423
INPUT 2
INPUT 2 value.
±200.00%
0.00%
100
INPUT 1
INPUT 1 value.
±200.00%
0.00%
309
INPUT 0
INPUT 0 value.
±200.00%
0.00%
Summary of Contents for 590SP
Page 2: ......
Page 16: ...1 4 590SP Digital Product Manual 1 Chapter 1 Introduction ...
Page 18: ...2 2 2 590SP Digital Product Manual Chapter 2 Identification ...
Page 31: ...Figure 3 3 Wiring Circuit Diagram for 590SP Digital Drive ...
Page 41: ...4 10 4 590SP Digital Product Manual Chapter 4 Start up and Adjustment DIGTIAL ...
Page 67: ...6 590SP Digital Product Manual Chapter 6 Service and Maintenance 6 6 ...
Page 89: ...B Appendix B Using the Man Machine Interface App B 4 590SP Digitial Product Manual ...
Page 125: ...Appendix C Setup Parameters 590 DRV Digital DC Drive Product Manual App C 36 C ...
Page 149: ...Appendix D I O Configuration System Menu App D 24 D 590SP Digital DC Drive Product Manual ...
Page 150: ...t t t t Figure D 20 590SP Digital Software Block Diagram ...
Page 160: ...590SP Digital Product Manual App E 10 E Appendix E MMI Parameter List ...
Page 168: ...Appendix G RS232 System Port P3 590SP Digital Product Manual App G 6 G ...
Page 194: ...Appendix H RS422 Communications Ports P1 P2 590SP Digital Product Manual App H 26 H ...
Page 220: ...App L 6 590SP Digital Product Manual L Appendix L 590SP DRV Option ...
Page 221: ...Figure L 5 Wiring Circuit Diagram for 590SP Digital DRV Drive ...
Page 259: ...590SP Digital Product Manual App M 38 Appendix M Special Blocks and Application Notes M ...