MODEL 346 INSTALLATION AND OPERATION MANUAL
Annex A
Page A - 29/30
HA243821
Issue 5 Mar 98
Notes:
1.
Not applicable to thermocouple inputs
2.
For thermocouple linearisations only,
enter actual external temperature in
Instrument configuration.
These menus appear
only if the relevant
options are fitted
Set softkey on
or off
Background
display
Select totaliser
to be displayed
Reset selected
totaliser
Set primary
chart speed
Set chart
advance
on or off
Set chart hold
on or off
Set pen park
on or off
Set alarm
setpoints
Enter batch
number
Initiate log
printing
Select timer for
display
Select range
mag on or off
Print replay
history?
Set alternative
chart speed
on or off
Inhibit alarm
message
printing?
Select derived
variable for
viewing
Reset selected
derived
variable
Print custom
message
Set time and
date
View
instrument
alarms?
If option is fitted
If access
enabled in
instrument menu
If option is fitted
If access
enabled in
instrument menu
If option is fitted
If option is fitted
If option is fitted
If option is fitted
If option is fitted
If any instrument
alarm active
Enter
password
Select channel
for
configuration
Select DV1 to
DV9, or Off as
source
Note 1
Note 2
Channels
1 to 6
CHANNEL
Channels
7 to 9
Select
Instrument
configuration
Select alarm
configuration
Select relay to
be configured
Select totaliser
for
configuration
Select logging
functions for
configuration
Select
message to be
configured
Select timer to
be configured
Select trace
history for
configuration
Select range
magnify for
configuration
Select derived
variable for
configuration
Select comms
for
configuration
Select retrans-
mission output
for configuration
View
instrument
alarms
Select
calibration
change
Enter
alternative
chart speed
Enter action
equation for
above
Enter action
equation for
chart hold
Select print
mode
Enter ID
number
Select time
format
(12/24 hr)
Select chart
speed units
Enable/disable
softkey access
Enter softkey
descriptor (if
enabled above)
Enter new
password
Enable/disable
alarm access
Enter custom
curve
Enter external
cold junction
temperature
INSTRUMENT
Select alarm
channel
Select alarm
number
Select alarm
type
Enter setpoint
Enter
hysteresis
Enter
deadband if
applicable
Set alarm print
on or off
Enter rate
base if
applicable
Select relay
type
Enter source or
action equation
Select totaliser
type
Select totaliser
source
Enter factor
Enter totaliser
units
Enter preset or
cut-off values
Enable/disable
resetability
Enter reset
equation
Set counter
output on or off
Set output
factor
Enter
descriptor
Select
channels for
logging
Select
totalisers for
logging
Enter logging
action equation
Enter message
Select
message
colour
Select timer
type
Select period
or time-of-day
Enter period
or time as
appropriate
Enter reset
eqn. if period
timer selected
Select history
chart speed
Select
magnification
factor
Enter channels
for
magnification
Enter action
equation
Select
magnification
factor
Select
channels for
magnification
Enter action
equation
Select maths
function
Define
equation
inputs
Enter reset
equation if
applicable
Enter
descriptor
Enter units for
variable
Define decimal
point position
Select Baud
rate
Select parity
Select
XON/ XOFF
Select
read/write or
read only
Enter group ID
(GID)
Enter unit ID
(UID)
Select output
source
Select 0 to 20
or 4 to 20 mA
for output
Select low and
high o/p limits
Battery low
Bad ROM
Detail lost
Select
printhead
for cal.
Select channel
for cal.
Select CJC
sensor
calibration
Restore factory
calibration
Select servo
pen for
calibration
View options
Select
retransmission
o/p for cal.
ALARM
Enter alarm
mesage
RELAY
TOTALISER
LOGGING
CUSTOM
MESSAGES
TIMER
TRACE
HISTORY
RANGE
MAGNIFY
DERIVED
VARIABLES
COMMUNI-
CATIONS
RETRANS-
MISSION
INSTRUMENT
ALARMS
Note 3
CALIBRATION
If option is fitted
If option is fitted
Set function
type
Set function
units
Set decimal
point position
Enter
programmable
units string
Select input
type
Set function
low/high range
Set input
low/high range
Set chart
low/ high
Enter mag.
centre value
Set filter time
period
Set CJ type
internal or
external
Set trace on,
off or adaptive
Set
interpolation
on or off
Select trace
colour
Enter channel
descriptor
Enter channel
adjustment
Enter
programmable
units string
Select chart
low/high range
Enter channel
descriptor
Enter mag.
centre value
Set decimal
point position
Select units
Set
interpolation
on or off
Select trace
colour
Select DV
source
Enter message
action equation
A16.0 ACCESS TO CONFIGURATION DIAGRAM