10.8 Stand by
If enabled in the menu, standby function allows you to turn off the stove once the conditions
explained below are met. It is enabled if, at a given time by the parameter PR44, the room
temperature is higher than the set temperature (Set environment) plus the parameter PR43. The
display shows "
STANDBY
" and the remaining minutes. (
Figure 10
).
Figure 10
At the end of the time given by the parameter PR44, the display shows the message
"
WAIT COOLING
" In this state, the stove has turned off the auger (auger LED off), the heat
exchanger switches off when it reaches the threshold given by the parameter PR15 and the LED ON \
OFF flashes. (
Figure 10a
).
Figure 10a
When the fumes temperature reaches the threshold given by the parameter PR13, the stove goes
into stand-by mode and runs "
WAIT COOLING-
" on the display. The auger is off (auger LED off), the
exchanger is off (exchanger LED off), as well as the fumes fan. (
Figure 10b)
.
Figure 10b
If the room temperature drops below the set temperature (Set environment) minus the threshold
given by the parameter PR43, the stove will switch on again.
Standby
WAIT
COOLING
WAIT
COOLING -