Before switching on the stove, the display appears as shown in
Figure 2.
Figure 2
To turn on the stove, press on P4 for a few seconds. The successful ignition is indicated in the display
with the message "
START
" as (
Figure 3
). This phase lasts for a time given by the parameter
PR01.Under these conditions, the stove will go in the state of preheating, the glow plug turns on
(shown by the glow plug LED) and so does the fan fume extraction. Malfunctions during the ignition
phase are shown on the display and the heater goes into an alarm state.
(refer to chapter 9).
Figure 3
10.2 Pellet uploading
After about 1 minute the uploading phase begins, the display scrolls the message "
LOAD PELLET
".
In a first step the auger provides to load the pellets in the brazier for a time given by the parameter
PR40 (auger LED lit), the speed of the fumes is defined by parameter PR42 and the glow plug is
always lit (glow plug LED lit). In the second phase, after the time of the parameter PR40 has passed,
the auger turns off (auger LED off) for a time given by the parameter PR41, while the speed of the
fumes and the glow plug remain in the previous state. If the stove does not power up after this
phase, the auger turns on for a period given by the parameter PR04, the fumes speed is given by the
parameter PR16 and the glow plug is lit. (
Figure 4
).
Figure 4
14:15
22.5°
c
p-2
off
14:15
22.5°
c
p-2
start
14:15
22.5°
c
p-2
Load
pellet