background image

User Manual 

Dear Customer 

We thank you and we are honored that you have chosen one of our products. 

Please read this 

manual carefully

; in it you will find all the information and helpful tips for using the product with 

the maximum safety and efficiency. The manual supplied with the stove should be guarded and in 
case of loss or destruction of the same it is necessary to request a copy from your dealer or from 
the company, specifying the serial number of the stove, on the back wall. 

Summary 

1 Misconduct 
2 Safety 
3 Warnings 
4 Regulations and declaration of conformity 
5 Warranty 
6 Liability 
7 Installation 
8 Specifications 
9 First ignition 
10 Modes of Operation 
11 The menu 
12 Alarms 
13 Maintenance, cleaning, testing the stove 
14 Spare Parts 
15 Wiring Diagram 
16 Duct 
17 Notes 

Pag 2 
Pag 3 
Pag 3 
Pag 4 
Pag 4 
Pag 5 
Pag 5 
Pag 11 
Pag 14 
Pag 16 
Pag 21 
Pag 30 
Pag 35 
Pag 38 
Pag 40 
Pag 41 
Pag 43 

 

1 Misconduct

 

 

In this section we will draw up a list of some small rules to follow for the correct working of the 
stove and safety. 

All the operations not provided for in the manual and not authorized by a technician 
recommended  by  the  company,  must  be  considered  dangerous.  Otherwise  the  ZF 
company does not assume any responsibility both civil and criminal. 

 

Strictly prohibited 

-

 

Not observing the use and maintenance manual. 

-

 

Using the stove for any other use not provided for ( exclusively for heating). 

-

 

Touching the surfaces of the stove when it is hot.  

-

 

Use of the stove by children or disabled without assistance.  

-

 

Use of the stove by people who don’t know the safety regulations.  

-

 

Feeding pellets manually into the brazier. 

-

 

Working the stove with broken or not compliant parts (irregular flue, splintered glass, non-
original spare parts, etc.) 

-

 

In case of misfire, restarting the stove without first having emptied the brazier. 

-

 

In case of misfire, restarting the stove without first having waited 10-15 minutes. 

-

 

Throwing away unburnt pellets (still burning), after having cleaned the brazier. 

-

 

Feeding pellets recycled from the firebox or brazier. 

-

 

Neglecting stove cleaning ( glass and flue included). 

-

 

Cleaning  the  stove  with  water  (  water  could  filter  through  the  inside  of  the  stove  and 
damage its electric parts). 

Summary of Contents for PASUBIO

Page 1: ...Use and maintenance manual for pellet stove...

Page 2: ...working of the stove and safety All the operations not provided for in the manual and not authorized by a technician recommended by the company must be considered dangerous Otherwise the ZF company d...

Page 3: ...or criminal liability Before performing any operation the user must have read and understood all the contents of this manual Use and Maintenance Tampering and misuse of the stove can be dangerous for...

Page 4: ...62233 EN 14785 The installation and use of the stove must be met in all the local and national laws and all European standards 5 Warranty Warranty conditions ZF Ltd located in Dino Fochesato Street n...

Page 5: ...lid in the following cases The above warranty terms have not been observed The installation is not carried out in full obedience of the laws in force and the instructions contained in the provided man...

Page 6: ...ubject to wear and tear are excluded from the warranty Gaskets Ceramic tempered glass Linings and grills Varnished details Chromate gilded Satin Majolica Handles Power lines Vermiculite Refractory mat...

Page 7: ...iance with safety regulations Installation by unqualified and untrained personnel Installation not in accordance with the regulations in force in the country Use of non original spare parts Exceptiona...

Page 8: ...t where the stove is placed It is not compulsory to connect the air pipe of the stove directly outside see figure but it is necessary to guarantee at least 50m h of air Grill 800cm The electrical syst...

Page 9: ...h hermetically sealed gaskets It s important that the curvature of 90 provides for a T junction with inspection we advise you to use a curve of 45 Using nets or filters at the extremity of the flue or...

Page 10: ...the base can also be applied inside the house preferably external If there is a fireplace it must have a preferably circular internal section the square or rectangular sections must have rounded corn...

Page 11: ...products is assured windproof chimney pot The chimney pot must be positioned so as to ensure adequate dispersion and dilution of the combustion products and however outside the reflux area This area h...

Page 12: ...d consequently in the opposite situation increases the depression decreasing the draught To overcome these drawbacks the installer must act directly on the stove modifying the parameter to adjust the...

Page 13: ...ed power 104 6 C Flue gas temperature at reduced power 68 4 C Carbon dioxide at rated power 6 89 Carbon dioxide at reduced power 4 95 CO at 13 O2 at rated power 140 8 mg m CO at 13 O2 at reduced power...

Page 14: ...e to the stove or to the room of installation In case of problems the ZF company disclaims any liability both civil and criminal First steps Check that there are no objects on the stove manual include...

Page 15: ...the next submenu level PROGRAMMING It sets the selected menu and passes to the next entry 4 ON OFF WORK Pressed for 2 seconds it turns on and off the stove PROGRAMMING It passes to the next level of t...

Page 16: ...OF OPERATION Premise The installer must make the first start by taking precautions and must ensure that the safety devices are working properly Vacuum gauge hopper temperature protection etc Any anoma...

Page 17: ...1 minute the uploading phase begins the display scrolls the message LOAD PELLET In a first step the auger provides to load the pellets in the brazier for a time given by the parameter PR40 auger LED...

Page 18: ...tained in PR13 and maintained it for at least a time PR02 the stove goes into working mode which is the normal operating The display will show the word WORK The power is set by holding down the P5 and...

Page 19: ...Thus acting on the buttons P1 increase and P2 decrease it is possible to change the value After about 5 seconds the value is stored and the display returns to the normal mode or press P3 to exit Figu...

Page 20: ...this state the stove has turned off the auger auger LED off the heat exchanger switches off when it reaches the threshold given by the parameter PR15 and the LED ON OFF flashes Figure 10a Figure 10a...

Page 21: ...threshold given by the parameter PR10 the stove shuts off displaying the message OFF Figure 11a Figure 11a 11 THE MENU You can enter the menu by pressing the P3 button The menu is subdivided into diff...

Page 22: ...sday Prg 2 on off 15 Wednesday Prg 2 on off 16 Thursday Prg 2 on off 17 Friday Prg 2 on off 18 Saturday Prg 2 on off 19 Sunday Prg 2 on off 20 start Prg 3 OFF 0 23 50 21 stop Prg 3 OFF 0 23 50 22 Mond...

Page 23: ...info 04 Fumes state info 05 Fumes extraction revolutions state info Level 1 Level 2 Value M8 technician settings 01 access key set Level 1 Level 2 Value M9 exit 01 exit set 11 2 Menu M1 SET CLOCK Set...

Page 24: ...2c day figure 12d month figure 12e and year figure 12f by pressing the P1 button increment and P2 button decrement and confirming by pressing the P3 button Figure 12b Figure 12c Figure 12d Figure 12e...

Page 25: ...3a You can set two sections of functioning the first one with START1 Day and STOP1 Day and the second one with START2 Day and STOP2 Day delimitated by the times set according to the following table wh...

Page 26: ...2 3 05 TUESDAY PRG 1 on off M2 3 06 WEDNESDAY PRG 1 on off M2 3 07 THURSDAY PRG 1 on off M2 3 08 FRIDAY PRG 1 on off M2 3 09 SATURDAY PRG 1 on off M2 3 10 SUNDAY PRG 1 on off PROGRAM 2 Menu level Sele...

Page 27: ...ctioning of the stove for Sunday by setting Start2 weekend and Stop2 weekend WEEKEND PROGRAM Menu level Selection Meaning Possible values M2 4 01 WEEKEND TIME Enable weekend time ON OFF M2 4 02 STAR 1...

Page 28: ...e first ignition of the stove figura 17 when the pellet tank is empty After having selected the menu M6 the message P1 to load will pass on the display figure 17a Then press P1 increment The fumes fan...

Page 29: ...ed Meaning 3 1 Auger pellet load state 52 Time out Toff Thermostat state 106 Fumes temperature 1490 Fumes extraction speed Figure 18 11 9 Menu M8 Technician settings This menu entry is for the technic...

Page 30: ...nitiated for safety During the alarm phase the alarms LED will always be lit Alarm LED lit and when enabled the buzzer will sound intermittently If you fail to reset the alarm the stove will shut down...

Page 31: ...s expulsion is not detected by the board In this case reset the alarm by pressing the On Off button and contact an authorized service center Figure 23 12 5 Misfire Alarm It occurs when the ignition ph...

Page 32: ...p press the button put the cap back restart the stove and check if the environment fan is working correctly If the alarm persists call the Authorized Service Provider Figure 27 12 8 Alarm absence depr...

Page 33: ...an authorized service The flame did not send the fumes on right temperature within the prescribed time The pellet is finished refill the tank switch the stove on if the problem persists call the autho...

Page 34: ...hould be made when the ash reaches the edge of the same drawer it is strictly forbidden to light the stove if the ash goes beyond it Every day when you clean the brazier also check if the drawer is em...

Page 35: ...he inner walls of the stove with a brush Remove the brazier to proceed with the removal of interior walls Remove the internal bulkhead taking it by the two lower edges if this operation proves to be d...

Page 36: ...mber behind the support of the brazier there is another bulkhead to remove grab her by the edge and pull up Removed this piece the two rear bulkheads are released to remove them simply take them off E...

Page 37: ...eaning and physical state Do not reassemble broken or damaged parts may cause undesired operation of the stove Summary scheme of the cleaning and maintenance of the stove Daily Every 2 days Once every...

Page 38: ...r criminal arising from the use of non original spare parts also informs that the use of these voids the warranty on the stove You will find the complete list of spare parts and related code to commun...

Page 39: ...iore 1 35 R2600424 Ferma vetro laterale sx 1 36 R2600425 Tappo inferiore 1 37 R2600427 Staffa supporto serbatoio coclea 1 38 R2600428 Staffa supp motore coclea 1 39 R2600430 Braciere 6 9 kW EA 1 40 R2...

Page 40: ...Hereinafter the diagram for the connection between the different electric parts and the motherboard of the stove is represented TSP safety thermostat vain pellets 15 Wiring diagram...

Page 41: ...n The adjustment of the channeling can happen in two ways depending on the type of stove you have Manual Adjustment Automatic Adjustment Automatic Adjustment The adjustment of the air flow in this cas...

Page 42: ...Below is an example of installation of ducted heater in a home environment...

Page 43: ...17 Notes...

Page 44: ...Notes...

Page 45: ...xed municipal waste but it must be assigned to specialized collection structures as prescribed by local regulations or by the dealer The importer and the dealer are responsible for collection and disp...

Reviews: