background image

SAEY Home & Garden plc.   

 

 Documentation addressed to

 

Industrielaan 4   

 

 

 

  

the user and installer

 

8501 Kortrijk-Heule (Belgium) 

 

 

 

 

tel. (056) 36.14.55 - fax (056) 36.15.10   

 

            

 

 

 

 

 

 

OPERATING INSTRUCTIONS 

 

 

 

 

 

 

477.0220.000 

SAEY 200 & 200 + Anthracite 

477.0220.280 

SAEY 200 + Glossy dark blue 

 

 

e-mail 

477.2520.000 

SAEY 200 + CUCINA  Anthracite 

477.2520.280 

SAEY 200 + CUCINA  Glossy dark blue 

e-mail

 

 

 

 

 

 

 

 

  

 
 
 
 
 
 
 

 

Summary of Contents for 200+ series

Page 1: ...nd installer 8501 Kortrijk Heule Belgium tel 056 36 14 55 fax 056 36 15 10 OPERATING INSTRUCTIONS 477 0220 000 SAEY 200 200 Anthracite 477 0220 280 SAEY 200 Glossy dark blue e mail 477 2520 000 SAEY 2...

Page 2: ...d The danger then arises that the stove will become too hot and overheated so that slag formation takes place and the parts exposed to the flames are damaged The glass panel will become warped and glo...

Page 3: ...oors furniture woodwork etc must be at a distance of at least 60 cm Place your appliance at least 30 cm away from the wall The wall must consist of non flammable material 3 CONNECTING THE STOVE TO THE...

Page 4: ...ng precautionary measures before the smoke duct is installed The diameter of the smoke duct may not be reduced and it may not be positioned horizontally but should still rise towards the chimney at a...

Page 5: ...me the stove must be dried out first For this purpose use a little fuel to keep the fire burning for one hour When the top air sliders are open the glass is washed by an air current that glides over t...

Page 6: ...g them outwards Open the door with the glass panel and put crumpled newspapers over the floor with a handful of splintered wood thin wood on top of it After the stove has been lit the door with the gl...

Page 7: ...anger of asphyxiation danger of explosion Wood provides intense combustion of short duration Sustained combustion is only achieved through regular top ups This means only when the wood has almost been...

Page 8: ...the rear wall must be cleaned after every heating season at least 1 x a year By removing the control damper you will be able to reach the smoke discharge duct This makes it easy to remove the fly ash...

Page 9: ...aw materials or in the workmanship No further claims may be made THE MANUFACTURER DOES NOT GUARANTEE Parts that are subject to wear and tear and damage to and defects in the appliances or their parts...

Page 10: ...10 Secondary air conditioning inside closed outside open Maximum stacking height of logs Detail cucina upper plate Saey 200 cucina 040123...

Reviews: