Page 1: ...HSP 6 Pelletto IV 419 08 434 08 Equipment sheet Pellet stove GB 0541908171403b Equipment sheet HSP 6 Pelletto IV 419 08 434 08 ...

Page 2: ...the heating device or of an injury The note entitled Notice advises you on possible damage to your heating device The note entitled Important calls your attention to the information important for the operation of your heating device The note itself calls your attention to the information important for the operation of your heating device in general ...

Page 3: ...er function instruction Error F040 3 3 4 Cleaning the combustion pot weekly 3 4 Maintenance work 5 4 1 Cleaning the flue gas passes 5 4 2 Cleaning the pellet container annual maintenance 8 5 Replacement parts list 9 5 1 Replacement parts list HSP 6 Pelletto IV 419 08 434 08 without trim parts 9 5 2 Detail A1 11 5 3 Replacement parts list HSP 6 Pelletto IV 419 08 12 5 4 Replacement parts list HSP 6...

Page 4: ......

Page 5: ...ents of storage container pellet tank about 17 kg about 32 kg Duration of burn with one charge min max about 10 h 30 h about 20 h 60 h Permitted fuel Low dust wood pellets diameter 6 mm diameter 6 mm to Ö Norm M 7135 DIN plus EN plus A1 length max 30 mm length max 30 mm Room heating capacity to Ö Norm M 7521 max 230 m max 230 m Room heating capacity to DIN 18893 constant heating 250m 145m 98m 250m...

Page 6: ...Dimensions GB 2 2 Dimensions 2 1 Dimensions HSP 6 Pelletto IV 419 08 2 2 Dimensions HSP 6 Pelletto IV 434 08 ...

Page 7: ...ustion chamber function instruction Error F040 The whole combustion space must be cleaned after 30 hours operation at the latest or once a week The requirement to clean the fire box flickering of the display appears during heating in case that the cleaning interval has elapsed After the fire box has been cleaned the error message Clean the fire box will be confirmed automatically The condition for...

Page 8: ...ering in the pellet tank might possibly result This will destroy your device and is not covered in your guarantee WARNING Cleaning the combustion pot may only be done with a cooled down stove in OFF operating mode Otherwise there is a risk of burns Take out the burner bowl from the stove Remove the remains of ashes and slag After the cleaning mount the burner bowl back to its proper position on th...

Page 9: ...h content is higher 0 5 and over the interval from maintenance to maintenance is reduced and the accumulation of ash increases by 2 or 3 times WARNING Devices that are not maintained in accordance with our specifications must not be operated Failure to observe this point will invalidate all guarantee claims 4 1 Cleaning the flue gas passes CAUTION Check and clean the flue gas ways exhaust flue gas...

Page 10: ...Maintenance work GB 6 Figure 1 Removing the flue baffle ...

Page 11: ...work GB 7 Figure 2 Removing the side wall CAUTION After completion of the cleaning make sure that when putting back the covers the seals are seated in the right positions It is essential to replace defective seals ...

Page 12: ... 1 in the pellet tank may be removed Then clean the tank and the intake of the screw conveyor housing with a vacuum cleaner After cleaning it is essential to put back the protective grille When doing this make sure that no screws fall into the pellet tank so as to avoid consequential damage to the screw conveyor Figure 3 Pellet tank 1 Protective grille 2 Tank cover ...

Page 13: ...Replacement parts list GB 9 5 Replacement parts list 5 1 Replacement parts list HSP 6 Pelletto IV 419 08 434 08 without trim parts ...

Page 14: ... control unit 1 piece 0541908005569 12 Backup battery CR 2032 1 piece 13a Stand front 2 piece 0089501090005 13b Stand back 2 piece 0551908505005 14a Ignition 1 piece 0541908005202 14b Capsula porta accenditore 1 piece 0553808005215 15 Room temperature sensor 1 piece 0089500390005 16 Flue gas thermosensor 1 piece 0561008005540 17 OC 1 piece 0089500080005 18 Cover hinge pins DIN 427 M5x18 1 piece 05...

Page 15: ...1 Pos Description Piece No PR Detail A1 A1 1 Screwing door 1 piece 0541908305001 A1 2 Door hinge anthracite Set 1 piece 0541908005340 A1 2 Door hinge grey Set 1 piece 0541908006340 A1 3 Glass holder anthracite Set 1 piece 0551908005308 A1 3 Glass holder grey Set 1 piece 0551908025308 35 Combustion chamber door anthracite 1 piece 0541908005220 35 Combustion chamber door grey 1 piece 0541908006220 ...

Page 16: ...st HSP 6 Pelletto IV 419 08 Pos Description Piece No PR Replacement parts list HSP 6 Pelletto IV 419 08 39 Side wall left right anthracite 2 piece 0541908176140 39 Side wall left right grey 2 piece 0541908177140 39 Side wall left right white 2 piece 0541908178140 40 Front plate grey 1 piece 0541908177130 40 Front plate anthracite 1 piece 0541908178130 41 Cover plate anthracite 1 piece 054190817716...

Page 17: ... 4 Replacement parts list HSP 6 Pelletto IV 434 08 Pos Description Piece No PR Replacement parts list HSP 6 Pelletto IV 434 08 43 Side wall left right grey 2 piece 0553808026140 44 Front plate anthracite 1 piece 0543408177130 45 Cover plate anthracite 1 piece 0541908177160 46 Back wall 1 piece 0546532615118 ...

Page 18: ...Circuit diagram GB 14 6 Circuit diagram Circuit diagram IO 33 3 ...

Page 19: ...conveyor motor 7 Induced draught 8 9 OC 35 36 Flue gas temperature sensor 37 38 Flame temperature sensor 39 40 Room temperature sensor 41 42 Bottom flame temperature sensor 43 44 Door contact switch 48 50 Flue gas fan rotation speed F1 Fuse T 3 15 A ignition induced draught fan screw conveyor motor F3 Fuse T 0 315 A operator console ...