After 6,000 kg Maintenance
Maintenance after 6,000 kg of pellets
When 6,000 kg of pellets have been used, a
screen message appears to notify of the need for
maintenance.
This maintenance must be performed
at least once
per heating season
.
Boiler
TU 4.4.2011 11:25:45
Cleaning after 6000 kg
Reminder for periodic cleaning of the boiler according to
user manual.
Confirm the message and then begin with the
maintenance.
Empty the ash box, check the boiler pressure
Empty the ash box and check the boiler pressure.
See page 11 and page 12.
Stop heating,
let boiler cool for at least 2 hours
Before starting this maintenance, stop the current
heating operation. In the "Boiler" overview, press
the on/off button
.
Then let the boiler cool off for at least 2 hours
before starting the maintenance.
After 6,000 kg
Empty ash box, check boiler pressure
Clean flue tube
Remove flue ash from chimney
Clean flue tube
Brush out the connection pipe from the flue outlet
to the chimney if it is longer than 0.5 m.
Remove flue ash from chimney
Use a vacuum cleaner to remove the flue ash from
the chimney.
Clean the condensate drain.