48
www.eta.co.at
Subject to change due to technical improvements
Room sensor with remote control
Heating circuit
Night-Clock-Day
The switch (1) can be used to set the following operating
modes:
= NIGHT or set-back mode
= AUTOmatic switching between DAY and NIGHT
= DAY or heating mode, even when the outside temperature
exceeds the set heating threshold.
Switching off the heating
During the transition period, the heating circuit can be
switched off by turning the switch (1) to the
position.
Correspondingly, turning the switch to the
or
position
switches on the heating circuit.
Changing the room temperature
The control knob (2) is used to increase or reduce the desired
room temperature by up to 5°C.
The actual room temperature is only displayed in the "Heating
circuit" function block if the control knob (2) is in the middle
position. A desired increase in temperature will be deducted
from the room temperature measured by the room sensor,
while a reduction will be added to it.
"Malfunction" indicator light
LED (3) fl ashes red = WARNING or ALARM present.
Adjusting the room sensor
Open the cover by pressing in the latch (4), and turn the control
knob (2) to the middle position.
The measured room temperature can be adjusted using
potentiometer P1 (5). The room temperature is displayed in the
overview of the "Heating circuit" function block.
Switching off the room sensor function
If the room sensor is in a room that is heavily affected by
extraneous infl uence, e.g. the kitchen or a living room with a
tiled stove, the room sensor must be switched off (see below).
If the room sensor is switched off, the control knob (2) affects
the fl ow temperature directly. If the temperature is set back by
3°C or more (factory setting) using the control knob, the heating
circuit pump is switched off.
Switching off the room sensor function:
Open the cover and move the jumper (6) from the right-hand
"S" position (sensor) to the left-hand "F" position (fi xed).
The target temperature and the set-back temperature in the
"heating circuit" function block must be set to 21°C. The fi xed
temperature in the room sensor must be also be adjusted to
21°C, using potentiometer P3 (7).
5
6
7
1
2
3
4
2
Warmer
Colder
Within this range, the
heating pump will be
switched off if the room
temperature sensor
is switched off
Room sensor with remote control
Room sensor with remote control