Overview, buttons, functions
Heating circuit
Heating circuit
"Heating circuit" overview
Press
and
to open the "Heating circuit 1"
overview screen.
Each heating circuit has its own function block
(HC2, HC3...).
In the overview of the selected heating circuit,
the on/off button
can be used to switch the
heating circuit on and off.
The timer can be used to set 3 different time slots
for each day of the week. If there is a room sensor
installed, you can also adjust the desired room
temperature.
If not, a slider on the overview screen allows you
to adjust the room temperature.
"Day" and "Night" mode
During the time slots, the heating circuit is in
"Day" mode.
Outside the time slots, the heating circuit is in
"Night" mode.
Slider
The slider is
only shown if there is no room
temperature sensor installed
. The slider can be
used to change the room temperature by approx.
+/- 5°C.
Please bear in mind that this substitute function
cannot replace the precision of a room sensor.
Timer
The timer shows the set
heating time slots for
the current day of the week
. Tapping this timer
brings up a screen where it is possible to set
3 time
slots for each day of the week
.
If a
room sensor
is
installed
, the desired
room
temperature
can be set for each time slot.
Likewise, the reduced room temperature (set-back
temperature) between the heating time slots can
also be adjusted.
Within a set time slot, the heating circuit will be in
"Day" mode. Outside of the time slots, it will be in
"Night" mode.
If the heating circuit is operated in
"Auto"
mode
(
button),
this button changes
the icon
depending on whether the heating
circuit is running at
"Day"
or
"Night"
temperature
.
Current room temperature
(room sensor only)
Only displayed if a room sensor is installed
for this heating circuit.
This displays the current
room temperature as measured by the room
sensor.
Current fl ow temperature
The current target fl ow temperature for the heating
circuit is only displayed if the heating circuit is
switched on and in operation.
Heating circuit on/off
This button is used to switch the heating circuit on
and off.
The boiler has a separate on/off button.
Green = Heating circuit on
Red = Heating circuit off
Overview, buttons, functions
Heating circuit