Entering stock
Pellet store
Entering stock
Entering new stock level
after a delivery of pellets
After the store has been fi lled with pellets, the
new stock quantity should be entered.
This way, the control system is always able to
calculate the approximate pellet stock level.
In the overview screen, tap the
button.
A screen opens:
Enter the new stock quantity and press
to save.
The display returns to the overview.
Aspirator delay
The discharge screw is switched off and the boiler
aspirator keeps running for the "Aspirator shut-off"
period in order to rinse the hoses.
Aspirator delay M
The maximum fi ll up time has been exceeded; the
aspirator will keep running for a short while.
Aspirator delay F
There is a problem with the discharge screw; the
aspirator will keep running for a short while.
Error fi ll up time
It was not possible to convey pellets to the boiler.
The pellet store may be empty, or the hoses may be
blocked.
At the end of the adjustable "Fill up time max",
pellet feeding is shut off.
Error Conveyor
There is a problem with the discharge screw. This
has been detected due to overcurrent, warming or
insuffi cient current consumption.
Entering stock