Operating modes
Heating circuit
Operating modes
On Night
The heating circuit is
outside of the timer's time
slots
and in
"Night" mode
.
The fl ow temperature of the heating circuit is
regulated using the "Heating curve night".
If the unit has a built-in room sensor, the
temperature is regulated to the stored "set-back
temperature". The switch can be in either the
"Auto" or the "Night" position.
Holiday On
The heating circuit is switched on and in holiday
mode (= constant "Night" mode). It remains in this
state until the "End of holiday" date.
On Delay
The heating circuit is no longer demanding any
heat and is in delay mode. The boiler pump is still
running for a short time in order to channel the
heat out of the boiler.
On Freezing room
The heating circuit is in operation because the
current room temperature is below the freezing
protection temperature (10°C).
On Freezing fl ow
The heating circuit is in operation because the
current fl ow temperature is below the freezing
protection temperature (10°C).
On Heat dissipation
The heating circuit is in operation in order to cool
the boiler by dissipating excess heat. Also displayed
during emission measurement.
On Overtemperature
The heating circuit is in operation because
the boiler is running at overtemperature. The
heating circuit is running at the highest set fl ow
temperature in order to dissipate the heat from the
boiler (overheating protection).
Holiday mode
The "Holiday" button is used to set a period for
which the
selected heating circuit
will run in
"Night" mode.
Any adjustments made to the room temperature
also infl uence the "Day" temperature, and thus
the temperature for heating up at the end of the
holiday. As such, it is best not to adjust the room
sensor for holiday set-back.
If you wish to reduce the room temperature, you
can set an individual "set-back temperature" in the
timer. During
"Holiday" mode, the lowest of all
the "set-back temperatures" in the timer is the
one that applies
.
On Day
Current operating mode
This line shows the current operating mode of
the heating circuit. Below is a list of the possible
modes:
On Day
The heating circuit is
within one of the timer's
time slots
and in
"Day" mode
.
The fl ow temperature of the heating circuit is
regulated using the "Heating curve day".
If the unit has a built-in room sensor, the
temperature is regulated to the highest room
temperature set for the time slot. The switch can be
in either the "Auto" or the "Day" position.
Operating modes