52
www.eta.co.at
Subject to change due to technical improvements
Overview, buttons, functions
Store with switching unit
Ready
The switching unit has reached the position for
conveying from a suction head. Filling up will
now begin.
Drive
The switching unit is switching between suction
heads.
Fill up
Filling up has started and pellets are being
conveyed.
Rinse
The switching unit has switched to rinse mode. The
conveying hose is now channelling in back air in
order to dislodge any blockages in the conveying
hose or suction head.
Overtime
It was not possible to fi ll up the storage tank
within the set "Fill up time max".
The pellet store above the suction head may be
empty or the hoses may be damaged.
Empty
After rinsing of all suction heads, followed by
attempted conveying of pellets, it was not possible
to fi ll the storage tank.
The pellet store may be empty or the hoses may be
damaged.
Reference
The switching unit is moving to its reference point.
Stop
Filling up has been stopped.
Locked
All suction heads have been locked. Conveying is
thereby prevented. At least one suction head must
be enabled.
Suction head 1 rinsing
Suction head 1 is being rinsed using a reverse
air blast.
Suction head 2 conveying
Pellets are being conveyed from suction head 2.
Suction head 2 rinsing
Suction head 2 is being rinsed using a reverse
air blast.
Suction head 3 conveying
Pellets are being conveyed from suction head 3.
Suction head 3 rinsing
Suction head 3 is being rinsed using a reverse
air blast.
Reference
Current operating mode
This line shows the current operating mode of
the pellet conveying system. Below is a list of the
possible modes:
Off
The pellet conveying system is not in operation.
There is no demand from the boiler.
Overview, buttons, functions