58
Address
Address range from 1~99
Multi loads communication
ON: One interface and address bit controls multiple
E-loads
OFF:
Multiple interfaces control multiple E-loads
OUTPUT
Output Mode
LEVEL- high level as default, low level when there is
an output
PLUSE-high level as default, output 5mS pulse when
the test result is qualified; output 10mS pulse when
the test result is unqualified
Condition
Qualified-output when the test is qualified
Failed- output when the test is failed
End: output when the test ended
Closed-no output
Fail Op.
Continue: continue testing when it fails
Stop: stop testing when it fails
COLOR
WIN
Green-font Green
Yellow-font yellow
Blue-font blue
Back Color
Light gray-light gray background
Dark gray- dark gray background
Black-black background
4.2.1 Remote Sense Compensation Mode
If the E-load consumes large current, a large voltage drop will be detected in connection
line between tested instrument and E-load terminal. To ensure measurement accuracy, a
remote sense measurement terminal is provided at E-load rear board to compensate
voltage drop lost in wire. Operation steps as below:
1. Press
to enter the parameter setting interface;
2.
Move the cursor to the test setting - the remote compensation sense
3.
Select ON/OFF to turn on/off remote sense function. Status bar shows REMOTE
when the remote sense function is ON.