83
Returns: 00.0000
27
POWer:PROTection?
Meaning: read the power protection value
Example: read the power protection value
Send: POWer:PROTection?
Returns: 00.0000
28
DYNamic:HIGH
Meaning: set high level loading current in dynamic mode
Example: set high level loading current at 3A in dynamic mode
Send: DYNamic:HIGH 3
Back: no
29
DYNamic:HIGH:DWELl
Meaning: set the duration for high level loading current in dynamic
mode Example: set the duration 5mS for high level loading current in
dynamic mode
Send: DYNamic:HIGH:DWELl 5
Back: no
30
DYNamic:LOW
Meaning: set low level loading current in dynamic mode
Example: set low level loading current at3A in dynamic mode
Send: DYNamic:LOW 1A
Back: no
31
DYNamic:LOW:DWELl
Meaning: set the duration for low level loading current in dynamic
mode Example: set low level loading current at 5A in dynamic mode
Send: DYNamic: LOW: DWELl 5
Back: no
ET System electronic GmbH