80
Meaning: set current rise time
Example: set current rise time 3A/uS
Send: CURRent: SLEW: RISE 3
Back: no
8
CURRent:SLEW:FALL
Meaning: set current fall time
Example: set current fall time 3A/uS
Send: CURRent: SLEW: RISE 3
Back: no
9
CURRent:PROTection
Meaning: set current protection value
Example: set current protection value to 3A/uS
Send: CURRent: PROTection 3
Back: no
10
POWer: PROTection
Meaning: set power protection value
Example: set power protection value to 150W.
Send: POWer: PROTection 150
Back: no
11
VOLTage:ON
Meaning: set Von value
Example: set the start voltage value to 10V
Send: VOLTage: ON 10
Back: no
12
VOLTage:OFF
Meaning: set the Voff value
Example: set the shutdown voltage value to 5V
Send: VOLTage: OFF 5
Back: no
13
MODE
Meaning: set working mode
Example: set CC mode
Send: MODE CURRent
Back: no
Parameter
Working mode
CURRent
CC mode
VOLTage
CV mode
POWer
CP mode