![Essemtec Paraquda Startup & Safety Manual Download Page 66](http://html1.mh-extra.com/html/essemtec/paraquda/paraquda_startup-and-safety-manual_2428336066.webp)
Human Machine Interface HMI
3-12
© Essemtec AG
Paraquda Startup & Safety
000
00
03/
11
/
N
ov
emb
er 4
, 2
01
4
Machine Module States
Overview
Overview Main
•
Parameter 'Initialized' (1)
•
Parameter 'Calibrated' (2)
•
Parameter 'Mode' (3)
•
Graphic Module (4)
State of Machine
Calib Mode Parameter
"Initialized"
Parameter
"Calibrated"
Parameter
"Mode"
Graphic
Module
Before 1st
Initialization
-
-
Initialized
Yes
Real
Not initialized (error) Yes
Real
Initialized
No
Real
Not initialized (error) No
Real
Initialized
Yes
Not
Real
Not initialized (error) Yes
Not
Real
Initialized
No
Not
Real
Not initialized (error) No
Not
Real