Interfaces and Connector Assignments
8.3 24V-Power Supply Voltage
The power supply voltage can be fed via connector 24V (X1) or optional via InRailBus (connector
assignment see page 76).
Device connector:
Phoenix Contact MSTBO 2,5/4-G1L-KMGY
Line connector:
Phoenix Contact FKCT 2,5/4-ST, 5.0 mm pitch, spring-cage connection
Phoenix Contact order no.: 1921900 (included in the scope of delivery)
For conductor connection and conductor cross section see page 77.
Pin Position:
Pin Assignment:
Imprint of the housing
24V
.
.
M
P
Imprint of the connector
(none)
(none)
-
+
Pin no.
1
2
3
4
Signal
Do not
connect!
Do not
connect!
M24
(GND)
P24
(+ 24 V)
Please refer to the connecting diagram page 13.
NOTICE
It is
not permissible
to feed through the power supply voltage through the 24V
connector and to supply the power supply voltage to another CAN module station!
A feed through of the +24 V power supply voltage can cause damage on the modules.
Signal Description:
P24... power supply v24 V ±10 %
M24... reference potential
CANopen-PN
Manual • Doc. No.: C.2921.21 / Rev. 1.6
Page 75 of 105