LBI-39190
44
FUSES
The Data Advantage VME Chassis contain several fuses. It is extremely rare for one of the fuses to need
replacement under normal circumstances. The Trouble Shooting section indicates when to check the fuses. This
section provides detailed information about the fuses.
CAP Board Fuse
Fuse Info:
A 1 Amp fuse is located in the middle of the CAP Board, near the VME bus
connectors. The 1992 boards contain a spare in the upper right corner. See the
Board Hardware Section for picture of location.
Purpose:
Pr12V supply to Ethernet Interface.
Indications of Bad Fuse:
IP Interface doesn’t work. Yellow Ethernet LED on Transition Module isn’t lit.
Possible Causes of Burn out.
Lightning, power surges, bad CAP board, bad Data Advantage power supply,
bad Transition Module, bad Adapter Board.
SCSI Fuse
Fuse Info:
A 1 Amp fuse is located on the Adapter Board on the back of the VME
backplane behind the CAP Board. The fuse is located near pin 1 of the J1 ribbon
cable connector.
Purpose:
Pr5V supply to SCSI Terminator Logic.
Indications of Bad Fuse:
Data Advantage can’t access the hard disk on boot up, attempts to reformat the
disk fail. Green SCSI Terminator LED on Transition Module isn’t lit.
Possible Causes of Burn out.
VMEAdapt boards not plugged in. Bad hard drive, floppy, Adapter Board, CAP,
or Transition Module.
This section is for Ericsson Service Personnel only.