LBI-39190
38
(continued)
Problem
Corrective Actions
Data Advantage
reboots itself
1. Check /activity/fatal.log for sideboard that requested the reboot. Swap out the board
and see if that corrects the problem. Note: The Data Advantage is not able to reboot
itself for CAP problems and some types of sideboard problems.
2. Replace the boards.
3. Replace Data Advantage chassis.
4. Replace the power supply in the VME chassis.
Data Advantage
Fails System
Startup
1. Verify that Data Advantage booted successfully (see above).
Diagnostic
Terminal Fails to
respond.
1. Verify that the terminal isn’t in block mode. If it is, press the block mode key again.
2. Check Terminal power and cable to Data Advantage.
3. Check Terminal fuse (if present).
4. Verify that Data Advantage is operational.
5. Restore factory setup, change emulation to VT100, and set tabs to every 8 columns.
6. Replace the Terminal.
Diagnostic
Terminal display
doesn't line up
correctly.
1. Set tabs to every 8 columns.
2. Restore factory setup, change emulation to VT100, and set tabs to every 8 columns.
3. Replace the Terminal.
Printer doesn't
work.
1. Verify that printer is on-line and has paper.
2. Check power and cable to Data Advantage.
3. Check for other alarms on printer and correct.
4. Verify that the Data Advantage is operational.
5. Replace the printer.
Telnet or FTP are
not accepted
1. Verify that host has the correct IP Address of the Data Advantage CAP External
Address.
2. Verify that the Host and Data Advantage can reach each other by using "ping" or
equivalent.
3. Verify both the Data Advantage's and host's network connections.
4. Verify that both the Data Advantage and host are operational.
5. Verify that the Max Telnet or FTP sessions is greater than 0 on the Data Advantage.
Login not accepted.
1. Verify spelling and case of login name and password.
2. Verify that login name is still valid in /etc/passwd.