LBI-39190
18
MVME147 BOARD SETUP
The Data Advantage equipment must be powered off when removing or inserting processor
boards.
WARNING
There are two types of processor boards installed in the Data Advantage VME chassis: MVME147 and
VCOM24. There will be only one MVME147 board, located in the bottom slot (slot 1). There will be one or
two VCOM24 boards, beginning at slot 3. Each of these boards requires the installation of an EPROM set and
the correct jumper settings for normal operation.
Shown below are the jumper settings for the MVME147 board. The two EPROMs for this board are to be
installed in U22 and U30. U1 and U15 will not have any EPROMs installed.
U30
U22
U15
U1
J1
J2
J3
J5
J6
J7
J8
J9
F1
Spare Fuse *
Figure 5 - MVME147 Board Jumper Settings, Fuses, and Sockets
* The Spare Fuse is on the 1992 revision of the board, but not the 1988 revision. The revision date is generally
on the back near the VME connectors.