5.
For use with floor sockets the devices have an opening on the bottom. Position
the open device so you can route the cable through the bottom opening and
connect the plug to the floor socket.
6.
Push the button on the inner side of the cover (opening at the front of the
device, I = ON, O = OFF) to start the device.
7.
After your exercise machine has been connected to mains and switched on, it
automatically carries out an operating check. During this operating check, you
will be able to read the software version of the unit on the display. Thereafter
the main menu will appear.
8.
Stand on the side of the control panel (view onto the display) and check if the
display works. If this is not the case, make sure you followed the steps above
correctly. In addition, verify if there is electricity in the mains socket.
5.4.1 Power supply
Use your exercise machine only with earthed (grounded) power sockets with 230 VAC
/ 50-60 Hz (see chapter A5). If you have any doubts about the power supply at the setup
location, ask your energy provider. Only use commercial 10 ampere automatic circuit
breakers (type B tripping characteristic). In the rare event that these automatic circuit
breakers should switch off when you switch on your machine, the circuit needs to be
fused with 10 A lead fuses or with a different type of tripping fuse (e.g. K-automat). In
case of doubt, ask your electrician.
Before connecting your ERGO-FIT exercise machine to your power supply system,
compare the acceptable voltage and frequency on the name plate (next to power entry
module) with your local data.