If the problem does not disappear or if it cannot be reproduced when these checks are
carried out, refer to "CR Motor Operation Abnormal" in Section 3.1.6.11.
7
Is a normal
voltage being
output from the
power supply
board?
Measurement points are shown below.
<+42 V measurement>
• Positive tester probe: Pin 1, pin 2
• Negative tester probe: Either pin 3, pin 4 or pin 8
<+5 V measurement>
• Positive tester probe: Pin 6, pin 7
• Negative tester probe: Either pin 3, pin 4 or pin 8
Table 3-11. Isolating the Faulty Part
on the Power Supply Board
Step
Check Point
Remedy
6-pin
2-pin
1-pin
7-pin
42VDC: 1,2 pin
5VDC: 6,7 pin
8
Even though the
power supply
board is
supplying a
normal voltage,
is the 3.3 V DC
power supply
voltage that is
used to control
the main board
normal?
Check whether the +5 V DC power supply voltage at IC9 on the
main board is being supplied correctly or not, and whether the
+3.3 V DC is being output normally from IC9.
Table 3-11. Isolating the Faulty Part
on the Power Supply Board
Step
Check Point
Remedy
Check Point 1
(for +3.3 VDC output
Check Point 2
(for +5 VDC input
Summary of Contents for Stylus Color C70
Page 1: ...EPSONStylusColorC70 C80 Color Inkjet Printer SEIJ01 004 SERVICE MANUAL ...
Page 5: ...Revision Status Revision Issued Date Description A July 31 2001 First Release ...
Page 9: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 35: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 60: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 96: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 137: ...C H A P T E R 5 ADJUSTMENT ...
Page 169: ...C H A P T E R 6 MAINTENANCE ...
Page 182: ...C H A P T E R 7 APPENDIX ...
Page 214: ......
Page 215: ......
Page 216: ......