I-40
EPSON
S5U1C88348T OPERATION MANUAL
APPENDIX LIST OF EVENTS BY MODE
Status
Mode
Sound demo mode
Display record
nop
nop
Keyword input submode starts
Record deletion submode starts
Initialize keyword input submode
Return to the previous mode (start record display submode)
Cannot be input
Cannot be input
Do nothing at the beginning line of
the melody data. Otherwise, scroll
the melody data up.
Do nothing at the last line of the
melody data. Otherwise, scroll the
melody data down.
When displaying last record in the
order sorted, display the first record.
Otherwise, display the next record.
When displaying the first record in
the order sorted, display the last
record. Otherwise, display the
previous record.
Valid
Start record edit submode
(title edit state)
Play the input melody data
nop
–
531
Input search keyword
After inserting a character, move the cursor to the right. Do nothing if the cursor is
positioned at the right edge of the line. Delete any characters overflowing from the
field.
The cursor moves to the next character to the left (no action taken when the cursor
is positioned at the beginning of the line) and delete the character. The separator
cannot be deleted.
nop
nop
First character selected state
321
Delete record
nop
nop
nop
nop
When [Y] is input, delete the relevant record and
display the next record in the order sorted (start
record display submode). If no other record exists,
display "NO RECORD EXISTING" for one
second, and start new data input mode. When [N]
is input, return to the previous mode. Do nothing
for any other key input.
Invalid
–
nop
–
541
Edit record
The cursor flashes
–
–
Power off
Top menu mode starts
Submenu mode starts
Delete the character at the cursor position. The separator cannot be deleted.
Submode
Detail
Initial setting
Design No.
General
key event
Number
Operation
key event
On/Off
Mode
Submode (Shift+Mode)
Enter
Esc
Erase
BS
Del (Shift+BS)
Char
Shift
Caps
Cursor (
↑
)
Cursor (
↓
)
Cursor (
→
)
Cursor (
←
)
Key repeat
Alphabet
Space
Kana (Char alphabet)
Symbol (Shift+No./alpha.)
C-Return (Shift+Enter)
[Sound Demo Mode 2]
System reset
Message display
→
Power off
Message display
→
Power off
Other
event
Reset key
Every second
Every 0.5 seconds
SVD error detected
KB is idle for 5 min.
Char state toggles
Shift state toggles
Caps state toggles
If no record is found, display the error message
"NO RECORD EXISTING" for one second.
Otherwise, display the record for which a
search was made (start record display
submode). (Records are scanned in the order
sorted. If no matching record is found, the
record closest to the keyword is displayed.)
Input title
First character (separator) selected state
511
Input melody data
512
nop
nop
After inserting a character, move the cursor to the right.
When positioned at a field terminator, the cursor does not
move. When positioned at the end of a line other than a
field terminator, the cursor moves to the left edge of the
next line. Delete any characters overflowing from the field.
Do nothing for [9], [0], and [Z].
Play the input melody data
If no data is found, display the error
message "NO TITLE FIELD" for
one second, then return to the
previous mode. Otherwise, move
the cursor to the melody data input
field.
When no space is available for user memory, display the
error message "USER MEMORY OVER FLOW" for one
second, then return to the previous mode. Otherwise,
save the data (sorted in order of title character code, with
entries of the same title sorted in the order in which they
were registered), and return to the title input initial state.
The cursor moves to the next character to the left (no
action taken when the cursor is positioned at the
beginning of the field; or when located at the beginning of
the second or subsequent lines of the field, the cursor
moves to the right edge of the preceding line) and delete
the character. The separator cannot be deleted.
Do nothing if the cursor is positioned at the first line of the
field. When positioned at the second or subsequent lines,
move the cursor to the closest character one line above.
Do nothing if the cursor is positioned at the bottom line of
a field. Otherwise, move the cursor to the closest
character one line below.
The cursor moves to the next character to the right. No action is taken when the
cursor is positioned at a separator.
The cursor moves to the next character to the left. No action is taken when the
cursor is positioned at the left edge of the line.
The cursor moves to the character to the right. No action
is taken when the cursor is positioned at a field
terminator. When positioned at any other position along
the right edge of the line, the cursor moves to the
beginning of the next line.
The cursor moves to the character to the left. No action is
taken when the cursor is positioned at the beginning of
the field. When positioned at any other position along the
left edge of the line, the cursor moves to the right edge of
the preceding line.
Summary of Contents for S5U1C88348T
Page 4: ......
Page 5: ...S5U1C88348T I Operation Manual ...
Page 6: ......
Page 8: ......
Page 50: ......
Page 51: ...S5U1C88348T II Hardware Manual ...
Page 52: ......
Page 54: ......