SIC63616-(Rev. 1.0) NO. P215
3240-0412
A.3.2 Downloading Circuit Data 2
- when previous ICE (S5U1C63000H1) is used
The standard ICE (S5U1C63000H1, previous model) did not support the circuit data download function for
the S5U1C63000P6 board. To use the download function, update the ICE firmware according to the follow-
ing procedure.
1) Set the baud rate of the ICE to 9600 bps. Refer to the manual supplied with the ICE for setting the DIP
switch.
2) Connect the ICE to the host PC and then start up the host PC in DOS. When Windows is running, restart
in DOS mode.
Note: Do not use the DOS prompt of Windows.
3) Turn the ICE on.
4) Configure the RS232C parameters for the host PC as follows:
C:\>MODE COM1:9600,n,8,1,p
(9600 bps, 8-bit data, 1 stop bit, no parity)
5) Copy the following files included in the assembler package (ver. 5 or later) to a directory on the hard
disk.
tm63.exe, ice63.com, i63com.o, i63par
6) Move to the directory in Step 5, run the TM63. TM63 enters command ready status after invocation,
enter a command as follows:
C:\>t
________
m63 xat
TM63 start on IBM PC
TM63 start V01.01
>d
________________________________
lf ice63.com i63com.o i63par 0b
...
>q
_
7) Enter "q" to terminate TM63 after the prompt mark is displayed.
8) The ICE firmware is now updated. Turn the ICE off and then download the circuit data by the proce-
dure described in Section A.3.1.