4.11.4 Setting of buzzer frequency and sound level
The divided signal of the OSC1 oscillation clock (32.768 kHz) is used for the buzzer signal and it is set up
such that 8 types of frequencies can be selected by changing this division ratio. Frequency selection is done
by setting the buzzer frequency select register BZFQ0–BZFQ2 as shown in Table 4.11.4.1.
Table 4.11.4.1 Buzzer signal frequency setting
Buzzer frequency (Hz)
4096.0
3276.8
2730.7
2340.6
2048.0
1638.4
1365.3
1170.3
BZFQ0
0
1
0
1
0
1
0
1
BZFQ1
0
0
1
1
0
0
1
1
BZFQ2
0
0
0
0
1
1
1
1
The buzzer sound level is changed by controlling the duty ratio of the buzzer signal.
The duty ratio can be selected from among the 8 types shown in Table 4.11.4.2 according to the setting of
the buzzer duty select register BDTY0–BDTY2.
Table 4.11.4.2 Duty ratio setting
BDTY0
0
1
0
1
0
1
0
1
BDTY1
0
0
1
1
0
0
1
1
BDTY2
0
0
0
0
1
1
1
1
Level
Level 1 (Max.)
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8 (Min.)
4096.0
2048.0
8/16
7/16
6/16
5/16
4/16
3/16
2/16
1/16
3276.8
1638.4
8/20
7/20
6/20
5/20
4/20
3/20
2/20
1/20
2730.7
1365.3
12/24
11/24
10/24
9/24
8/24
7/24
6/24
5/24
2340.6
1170.3
12/28
11/28
10/28
9/28
8/28
7/28
6/28
5/28
Duty ratio by buzzer frequency (Hz)
When the high level output time has been made TH and when the low level output time has been made TL
due to the ratio of the pulse width to the pulse synchronization, the duty ratio becomes TH/(TH+TL).
When BDTY0–BDTY2 have all been set to "0", the duty ratio becomes maximum and the sound level also
becomes maximum. Conversely, when BDTY0–BDTY2 have all been set to "1", the duty ratio becomes
minimum and the sound level also becomes minimum.
The duty ratio that can be set is different depending on the frequency that has been set, so see Table 4.11.4.2.
Level 1 (Max.)
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8 (Min.)
TL TH
Fig. 4.11.4.1 Duty ratio of the buzzer signal waveform
Note: When a digital envelope has been added to the buzzer signal, the BDTY0–BDTY2 settings will be
invalid due to the control of the duty ratio.