MOVERIO Pro Developer's Guide (Rev.1.4)
57
5.7.
Others
5.7.1.
Timing for reflecting the setting for the voice recognition start conditions
When audio input recognition switches from disabled to enabled, the voice recognition start
conditions are reflected in the system.
Therefore, if you change the recognition start conditions when audio input is enabled, once call
IVoiceCommandInterface.stop(), disable audio input and call IVoiceCommandInterface.setSnr() to
set the voice recognition starting condition. After IVoiceCommandInterface.start() is called,
setting is then reflected by the system.
5.7.2.
Recommended value of voice recognition starting condition
When recognition errors occur often due to noise of using environment, recognition errors can be
reduced by changing the voice recognition starting condition according to the noisiness(noise
level).
Recommended value for each noise level is as below. This parameter is a setting value to have
better voice recognition under white noise or machine noise. Optimum value is different by the
noise type, so please set according to the actual used environment. For setting method, refer to
5.4 Application interface list.
Noise level(dB)
Noisiness
S/N ratio Amplitude
35dB
Silent
10
1000
55dB
Little noisy
15
1500
70dB
Noisy
15
2500
For default value, refer to 5.5.1 setSnr and 5.5.3 setAmp.
S/N ratio
Amplitude
Default value
10
1024
Summary of Contents for Moverio Pro BT-2000
Page 7: ...MOVERIO Pro Developer s Guide Rev 1 4 1 1 Introduction ...
Page 12: ...MOVERIO Pro Developer s Guide Rev 1 4 6 2 Developing Apps ...
Page 30: ...MOVERIO Pro Developer s Guide Rev 1 4 24 3 Display control ...
Page 39: ...MOVERIO Pro Developer s Guide Rev 1 4 33 4 UI control ...
Page 47: ...MOVERIO Pro Developer s Guide Rev 1 4 41 5 Voice commands ...
Page 70: ...MOVERIO Pro Developer s Guide Rev 1 4 64 6 Camera control ...
Page 119: ...MOVERIO Pro Developer s Guide Rev 1 4 113 7 Sensor control ...
Page 127: ...MOVERIO Pro Developer s Guide Rev 1 4 121 8 Bluetooth BLE ...
Page 184: ...MOVERIO Pro Developer s Guide Rev 1 4 178 9 Power control ...
Page 187: ...MOVERIO Pro Developer s Guide Rev 1 4 181 10 Self diagnostic function ...
Page 191: ...MOVERIO Pro Developer s Guide Rev 1 4 185 11 GPS Assist ...
Page 202: ...MOVERIO Pro Developer s Guide Rev 1 4 196 Memo ...